NPSH, Cavitation and the Suction Side

Lesson 7 of 10 23 min read
Found this useful?

A pump starts to sound as if small stones are passing through it. The pressure gauge on the discharge shakes, the flow falls, and after one season the impeller comes out with holes in it like a sponge. The pump was not faulty. The water at its inlet was turning to vapour, because the suction side could not supply enough pressure. This lesson shows how to calculate the pressure margin at a pump inlet, called NPSH, and how to lay out a suction line that keeps that margin at every flow, temperature and altitude. #NPSH #Cavitation #PumpSuction

Learning Objectives

By the end of this lesson, you will be able to:

  1. Explain what cavitation is, why it is heard as noise and seen as vibration and falling head, and why it destroys impellers
  2. Calculate the NPSH available at a pump inlet from the atmospheric pressure, the vapour pressure, the liquid level and the suction losses
  3. Compare NPSH available with the maker’s NPSH required and state the margin
  4. Predict how altitude, hot water, a suction lift and a blocked strainer each reduce the margin
  5. Apply the design rules for a suction line

Real-World System Problem: One booster pump in two positions



The booster pump of this course stands at ground level under a storage tank. The water surface is about 15 m above the pump, so water arrives at the inlet under pressure. Engineers call this a flooded suction. In this position the pump is very hard to cavitate.

Now take the same pump to a second site at the same altitude and place it above an open sump, with the water surface 3.5 m below the pump. The pump must lift the water to itself. Nothing pulls water up a suction pipe: the atmosphere pushes it up, and at 1,600 m it pushes less than at sea level. The pump works on a cool morning. It may not work when the strainer is half blocked, or when the water is hot.

The pump is identical in both places. What changes is the pressure the suction side delivers to the inlet, and that decides whether the pump lives for fifteen years or for one.

PumpPumpTank~~~~~~~~~~~Flooded suctionSuction lift15 m3.5 m~~~~~~~~~~~~straineropen sump
The same pump with a flooded suction and with a lift

Fundamental Theory: Pressure at the pump inlet



Water boils when the pressure falls

Water boils when its vapour pressure equals the pressure around it. In an open pot at sea level that happens at 100 °C. Lower the pressure and the boiling temperature falls. At the 83.5 kPa of this site, water boils at about 95 °C. Lower the pressure to 2.34 kPa and water boils at 20 °C.

So water has a vapour pressure at every temperature. Where the absolute pressure in the liquid falls to , bubbles of vapour form, with no heating at all.

Water temperature (°C)Vapour pressure (kPa)Density (kg/m³)
202.34998
407.38992
6019.9983
8047.4972

These are standard values from steam tables. The vapour pressure rises very fast with temperature: from 20 to 60 °C it grows more than eight times.

What happens inside the pump

The lowest pressure in a pumping system is not at the inlet flange. It is just inside the impeller, at the entry of the blades. The water speeds up to enter the impeller and has to turn onto the moving blades, and both actions cost pressure before the blades begin to add any.

p●strainer, pipe, bend●pump inlet flangeblades__addpressurevapour pressurepathsurfaceinletlowest point(blade entry)
Absolute pressure from the liquid surface to the impeller

If the lowest point touches the vapour pressure, bubbles form there. The flow carries them along the blade into higher pressure, where each collapses in a few millionths of a second. This forming and collapsing of vapour bubbles is cavitation.

A collapsing bubble fires a very small, very fast jet of water at the nearest surface, with a local pressure far above the strength of the metal. One collapse does nothing visible; thousands a second on the same patch of blade break out grains of metal. The surface becomes rough, then pitted, then full of holes.

How cavitation shows itself

  • Noise. The collapses make a sharp crackling sound, as if gravel or glass beads were passing through the pump. It comes from the suction end of the casing.
  • Vibration. The collapses are not even round the impeller, so the shaft is shaken. Bearings and seals wear early.
  • Falling head and flow. Vapour takes up space between the blades and blocks part of the passage. The pump gives less head than its curve says, and the discharge pressure becomes unsteady.
  • Damage. Pitting on the blades near their inlet edge, found when the pump is opened.

A common mistake is to call every noisy pump a cavitating pump. Air drawn in through a leaking suction joint or a vortex at the pipe inlet also makes noise and reduces the head. Air does little damage to the metal, and the cure is different: find where the air enters.

Net positive suction head

To avoid cavitation, the water must arrive at the pump inlet with more energy than it needs to stay liquid. That surplus is the net positive suction head, NPSH. It is the total head at the pump inlet (pressure head plus velocity head, in absolute terms) above the vapour pressure head.

There are two NPSH values, and they come from two different sources.

  • NPSH available, , belongs to the system. You calculate it from the site, the liquid and the suction pipe.
  • NPSH required, , belongs to the pump. The maker measures it on a test stand and prints it as a curve against flow.

NPSH available

is the absolute pressure on the liquid surface (atmospheric for an open tank or sump), is the vapour pressure at the liquid temperature, is the density of the liquid and . is the height of the liquid surface above the pump inlet, negative when the surface is below the pump. is the head lost in the suction line between the surface and the inlet. Every term is in metres of the liquid.

The formula comes from the energy equation between the liquid surface and the pump inlet. The velocity head at the inlet is already inside it, so do not subtract it a second time.

Read the formula as an account with one income and three costs.

atmosphere, 83.5 kPa+8.53 m#################vapour pressure, 20 °C-0.24 m-lifttothepump-3.50 msuction loss-0.28 m-NPSH available4.51 m#########NPSH required2.56 m#####margin1.95 m####
NPSH available for a lift of 3.5 m at 18 m³/h

The only income is the pressure on the liquid surface. Everything else is a cost, except a liquid level above the pump, which adds its height.

Altitude and temperature

The atmosphere gives 101.3 kPa at sea level and 83.5 kPa at this site, about 1,600 m up. In metres of cold water, the first term of the formula falls from 10.11 m to 8.29 m: a design copied from a coastal site loses 1.82 m of NPSH available here, before any pipe is laid.

Temperature takes more. At 60 °C the vapour pressure is 19.9 kPa, and the first term at this site is only 6.60 m. So pumps for hot water are placed well below their supply tank, and a suction lift of hot water so often fails.

NPSH required and the margin

The maker finds by lowering the inlet pressure on a test stand until the head of the pump has fallen by 3 percent, the usual convention of the Hydraulic Institute and the test standards. So at the pump is already cavitating enough to lose head, and bubbles first appear well before that point.

So a pump needs a margin.

A common guide for cold clean water is a margin of about 0.5 to 1 m, or at least 1.1 to 1.3 times , with more for large or high-speed pumps. It is a guide only: the maker’s recommendation comes first. This lesson uses 1.0 m.

rises with flow, roughly with its square, because the velocity at the blade entry rises. falls with flow, because the suction loss rises. So the margin closes from both sides as the flow goes up.

NPSHavailable (falls with flow)●required (rises with flow)Qsafe marginmargin is zero
The margin closes as the flow rises

A common mistake is to check the margin only at the design flow. Check it at the largest flow the pump can reach, which is where cavitation begins.

Rules for the suction side

Each rule protects one term of the formula.

  • Put the pump as low as possible relative to the liquid surface. A flooded suction is always better than a lift.
  • Keep the suction pipe short, and at least one size larger than the pump inlet. A common guide for the velocity in a suction pipe is 1 to 1.5 m/s.
  • Keep the pipe straight for several diameters before the inlet (5 to 10 is a typical guide). A bend directly on the inlet sends an uneven flow into the impeller.
  • Use few fittings, and choose a strainer with a large open area. The strainer is usually the largest single loss, and the only one that grows with time.
  • Leave no place for air to collect. On a lift, the pipe should rise all the way to the pump. A reducer on a horizontal suction pipe is the eccentric kind with its flat side on top.
  • Keep the pipe inlet well below the liquid surface, so that no vortex draws air in.
  • Control the flow with a valve on the discharge or with the speed. Never throttle on the suction side: a half-closed suction valve is a blocked strainer by another name.

Application 1: The booster under the tank



Step 1: The atmospheric term

Click to reveal the head the atmosphere gives
  1. At the site.

    At this altitude the atmosphere, less the vapour pressure, is worth 8.29 m of water. ✅

  2. At sea level, for comparison.

    The site has 1.82 m less than a site at the coast. ✅

Step 2: The suction loss

Click to reveal the loss at both flows
  1. Velocity at 18 m³/h. Convert the flow: . The pipe area is .

    The velocity is inside the guide of 1 to 1.5 m/s. ✅

  2. Reynolds number and friction factor.

    The Swamee-Jain formula gives . ✅

  3. Loss at 18 m³/h. The pipe is worth velocity heads. The fittings are worth .

    The suction line loses 0.237 m, and the strainer alone is more than half of it. ✅

  4. Loss at 28 m³/h. The same steps give m/s, a velocity head of 0.12203 m, and .

    The loss is 2.4 times larger, for a flow 1.56 times larger. ✅

Step 3: NPSH available and the margin

Click to reveal the margin under the tank
  1. NPSH available.

    The available NPSH hardly changes with flow, because the 15 m of level is so much larger than the loss. ✅

  2. NPSH required.

    The requirement nearly doubles between the two flows. ✅

  3. Margin.

    (m³/h)Suction loss (m) (m) (m)Margin (m)
    180.23723.052.5620.49
    280.56822.724.4918.23

    The margin is 20.49 m at 18 m³/h and 18.23 m at 28 m³/h. That is very large: the pump has nine times what it requires at 18 m³/h and five times at 28 m³/h. ✅

  4. Check a second way. Find the absolute pressure at the inlet from the energy equation, then apply the definition of NPSH. At 18 m³/h the pressure head at the inlet is the level, less the loss, less the velocity head:

    The result is the same. A gauge at the inlet would read kPa, which is how the calculation can be checked on site. ✅

Application 2: The same pump lifting from a sump



Step 1: Cold water, clean strainer

Click to reveal the margin on a lift
  1. Suction loss with 6 m of pipe. The velocity heads and friction factors are those of Application 1. The pipe term doubles to at 18 m³/h and 1.514 at 28 m³/h.

    The longer pipe adds only 0.04 m at 18 m³/h. ✅

  2. NPSH available. The level is now a cost.

    Moving the pump from under the tank to above the sump has removed 18.5 m of NPSH available. ✅

  3. Margin.

    At 18 m³/h the margin is 1.95 m, above the guide of 1.0 m. At 28 m³/h it is negative: the pump cavitates. ✅

Step 2: A blocked strainer

Click to reveal what dirt on the strainer costs
  1. New fitting total. velocity heads, against 3.9 when clean. ✅

  2. Suction loss.

    The loss is 3.3 times the clean value at both flows. ✅

  3. NPSH available and margin.

    At 18 m³/h the pump still has 1.32 m. At 28 m³/h it is 1.89 m short. ✅

Step 3: Hot water

Click to reveal the effect of 60 °C
  1. Atmospheric term for hot water. Use the vapour pressure and the density at 60 °C.

    Heating the water from 20 to 60 °C removes 1.69 m of NPSH available. ✅

  2. Suction loss. Hot water is less viscous, so the Reynolds number is higher ( at 18 m³/h) and the friction factor a little lower (0.0196). The loss is 0.271 m at 18 m³/h and 0.649 m at 28 m³/h, almost the same as with cold water. ✅

  3. NPSH available and margin.

    With water at 60 °C the margin at the best efficiency flow is only 0.26 m, well below the guide. ✅

Step 4: The flow where the margin is zero

Click to reveal the limit of each case
  1. Solve numerically. The friction factor changes a little with flow, so the equation is solved with a root finder in the Python script.

    CaseMargin at 18 (m)Margin at 28 (m)Margin is zero at (m³/h)Margin at 23.34 (m)
    Cold, clean strainer+1.95-0.3626.7+0.84
    Cold, blocked strainer+1.32-1.8922.7-0.22
    60 °C, clean strainer+0.26-2.0519.4-0.84

    The margin reaches zero at 26.7, 22.7 and 19.4 m³/h. ✅

  2. Read the table against the pump’s range. On its distribution system this pump reaches 23.34 m³/h at full speed. With cold water and a clean strainer it keeps 0.84 m there, a little under the guide. With a blocked strainer or with hot water, the zero point lies inside the working range, and the pump cavitates whenever the demand is high. ✅

  3. Check by hand. For the first case, treat the loss as proportional to the square of the flow: m per (m³/h)². Then

    The hand value is 26.6 m³/h against 26.7 from the root finder. The small difference is the fall of the friction factor with flow. ✅

  4. The same lift at sea level. With 10.11 m in place of 8.29 m, the margin at 18 m³/h would be 3.77 m in place of 1.95 m. Nearly half of the margin is lost to altitude alone. ✅

Verify It in Python



The script calculates the suction loss with the Swamee-Jain friction factor, then the NPSH available and the margin for every case in both applications. It finds each zero-margin flow with a root finder and saves one plot of NPSH against flow.

npsh_margin.py
"""NPSH available against NPSH required for the booster pump."""
import numpy as np
from scipy.optimize import brentq
import matplotlib.pyplot as plt
G = 9.81
D, EPS = 0.080, 0.045e-3 # suction pipe: 80 mm steel
P_SITE, P_SEA = 83.5e3, 101.3e3 # atmospheric pressure, Pa
COLD = dict(rho=998.0, nu=1.004e-6, pv=2.34e3) # water at 20 degC
HOT = dict(rho=983.0, nu=0.475e-6, pv=19.9e3) # water at 60 degC
K_ENTRY, K_BEND, K_CLEAN, K_BLOCKED = 0.5, 0.9, 2.5, 15.0
Q_NAT = 23.34 # booster's natural duty flow, m3/h
def suction_loss(q_m3h, length, k_strainer, nu):
"""Head lost between the liquid surface and the pump inlet, in m."""
v = (q_m3h / 3600.0) / (np.pi * D**2 / 4.0)
re = v * D / nu
f = 0.25 / np.log10(EPS / (3.7 * D) + 5.74 / re**0.9) ** 2
k_total = K_ENTRY + K_BEND + k_strainer
return (f * length / D + k_total) * v**2 / (2.0 * G), v, re, f
def npsh_r(q_m3h):
return 1.2 + 0.0042 * q_m3h**2
def npsh_a(q_m3h, z_s, length, k_strainer, water, p_atm=P_SITE):
h_atm = (p_atm - water["pv"]) / (water["rho"] * G)
return h_atm + z_s - suction_loss(q_m3h, length, k_strainer, water["nu"])[0]
def zero_margin_flow(z_s, length, k_strainer, water):
return brentq(lambda q: npsh_a(q, z_s, length, k_strainer, water) - npsh_r(q),
1.0, 80.0)
print("Atmospheric term (p_atm - p_vapour)/(rho g)")
print(f" site, 20 degC: {(P_SITE - COLD['pv']) / (COLD['rho'] * G):.2f} m")
print(f" sea level, 20 degC: {(P_SEA - COLD['pv']) / (COLD['rho'] * G):.2f} m")
print(f" site, 60 degC: {(P_SITE - HOT['pv']) / (HOT['rho'] * G):.2f} m")
print("Suction loss, 3 m pipe, clean strainer, 20 degC")
for q in (18.0, 28.0):
h, v, re, f = suction_loss(q, 3.0, K_CLEAN, COLD["nu"])
print(f" Q = {q:.0f}: V = {v:.3f} m/s, V2/2g = {v * v / (2 * G):.4f} m, "
f"Re = {re:.0f}, f = {f:.4f}, loss = {h:.3f} m")
print("Application 1: flooded suction, surface 15 m above the pump")
for q in (18.0, 28.0):
a = npsh_a(q, 15.0, 3.0, K_CLEAN, COLD)
print(f" Q = {q:.0f}: NPSHa = {a:.2f} m, NPSHr = {npsh_r(q):.2f} m, "
f"margin = {a - npsh_r(q):.2f} m, ratio = {a / npsh_r(q):.1f}")
print("Application 2: lift from a sump 3.5 m below the pump, 6 m pipe")
cases = (("clean strainer, 20 degC", K_CLEAN, COLD),
("blocked strainer, 20 degC", K_BLOCKED, COLD),
("clean strainer, 60 degC", K_CLEAN, HOT))
for name, k, water in cases:
print(f" {name}")
for q in (18.0, 28.0):
loss = suction_loss(q, 6.0, k, water["nu"])[0]
a = npsh_a(q, -3.5, 6.0, k, water)
print(f" Q = {q:.0f}: loss = {loss:.3f} m, NPSHa = {a:.2f} m, "
f"NPSHr = {npsh_r(q):.2f} m, margin = {a - npsh_r(q):+.2f} m")
print(f" margin is zero at Q = {zero_margin_flow(-3.5, 6.0, k, water):.1f} m3/h")
m = npsh_a(Q_NAT, -3.5, 6.0, k, water) - npsh_r(Q_NAT)
print(f" margin at the natural duty flow of {Q_NAT} m3/h = {m:+.2f} m")
a_sea = npsh_a(18.0, -3.5, 6.0, K_CLEAN, COLD, P_SEA)
print(f" same lift at sea level, 18 m3/h: NPSHa = {a_sea:.2f} m, "
f"margin = {a_sea - npsh_r(18.0):+.2f} m")
# ---------- Plot ----------
qq = np.linspace(4.0, 32.0, 200)
fig, ax = plt.subplots(figsize=(7.5, 4.8))
ax.plot(qq, npsh_r(qq), "k", lw=2, label="NPSH required")
ax.plot(qq, npsh_a(qq, 15.0, 3.0, K_CLEAN, COLD), label="available: under the tank")
for name, k, water in cases:
ax.plot(qq, npsh_a(qq, -3.5, 6.0, k, water), label=f"available: sump, {name}")
ax.set_xlabel("flow (m3/h)")
ax.set_ylabel("NPSH (m)")
ax.set_ylim(0, 25)
ax.legend(fontsize=8)
fig.tight_layout()
fig.savefig("npsh_margin.png", dpi=120)
print("Saved npsh_margin.png")

Expected output

Atmospheric term (p_atm - p_vapour)/(rho g)
site, 20 degC: 8.29 m
sea level, 20 degC: 10.11 m
site, 60 degC: 6.60 m
Suction loss, 3 m pipe, clean strainer, 20 degC
Q = 18: V = 0.995 m/s, V2/2g = 0.0504 m, Re = 79260, f = 0.0213, loss = 0.237 m
Q = 28: V = 1.547 m/s, V2/2g = 0.1220 m, Re = 123294, f = 0.0202, loss = 0.568 m
Application 1: flooded suction, surface 15 m above the pump
Q = 18: NPSHa = 23.05 m, NPSHr = 2.56 m, margin = 20.49 m, ratio = 9.0
Q = 28: NPSHa = 22.72 m, NPSHr = 4.49 m, margin = 18.23 m, ratio = 5.1
Application 2: lift from a sump 3.5 m below the pump, 6 m pipe
clean strainer, 20 degC
Q = 18: loss = 0.277 m, NPSHa = 4.51 m, NPSHr = 2.56 m, margin = +1.95 m
Q = 28: loss = 0.661 m, NPSHa = 4.13 m, NPSHr = 4.49 m, margin = -0.36 m
margin is zero at Q = 26.7 m3/h
margin at the natural duty flow of 23.34 m3/h = +0.84 m
blocked strainer, 20 degC
Q = 18: loss = 0.908 m, NPSHa = 3.88 m, NPSHr = 2.56 m, margin = +1.32 m
Q = 28: loss = 2.186 m, NPSHa = 2.60 m, NPSHr = 4.49 m, margin = -1.89 m
margin is zero at Q = 22.7 m3/h
margin at the natural duty flow of 23.34 m3/h = -0.22 m
clean strainer, 60 degC
Q = 18: loss = 0.271 m, NPSHa = 2.82 m, NPSHr = 2.56 m, margin = +0.26 m
Q = 28: loss = 0.649 m, NPSHa = 2.45 m, NPSHr = 4.49 m, margin = -2.05 m
margin is zero at Q = 19.4 m3/h
margin at the natural duty flow of 23.34 m3/h = -0.84 m
same lift at sea level, 18 m3/h: NPSHa = 6.33 m, margin = +3.77 m
Saved npsh_margin.png

In the plot, the line for the pump under the tank lies far above the others. The three lines for the sump cross the curve of NPSH required inside or just beyond the working range.

Common Mistakes



  • Using 101.3 kPa for a site that is not at sea level. At 1,600 m the atmosphere gives 1.82 m less head.
  • Using gauge pressure in the formula. NPSH is built from absolute pressures, and the vapour pressure in the tables is absolute.
  • Taking the vapour pressure at 20 °C for water that is warm. At 60 °C the vapour pressure is more than eight times larger.
  • Checking the margin only at the design flow. NPSH required rises and NPSH available falls as the flow rises, so the worst case is the largest flow.
  • Throttling a valve on the suction side to control the flow. It removes NPSH available in the same way as a blocked strainer.

Summary



  • Cavitation is the forming of vapour bubbles where the pressure falls to the vapour pressure, and their violent collapse on the impeller. It is heard as a gravel noise and seen as vibration, falling head and pitted blades.
  • NPSH available is . It belongs to the system. NPSH required belongs to the pump and rises with flow.
  • At this site the atmospheric term is 8.29 m with water at 20 °C, against 10.11 m at sea level, and 6.60 m with water at 60 °C.
  • Under the tank the booster has a margin of 20.49 m at 18 m³/h and 18.23 m at 28 m³/h.
  • Lifting 3.5 m from a sump, the margin is 1.95 m at 18 m³/h and is zero at 26.7 m³/h. A blocked strainer moves the zero to 22.7 m³/h, and water at 60 °C moves it to 19.4 m³/h.
  • A good suction line is low, short, large and straight, has a clean strainer, and has no place where air can collect.

Exercises



1. Find the atmospheric term at this site (83.5 kPa) for water at 40 °C, with kPa and .

Answer

m. That is 0.47 m less than with water at 20 °C.

2. The tank of Application 1 is nearly empty, with the surface 1.0 m above the pump inlet. The suction loss at 28 m³/h is 0.568 m. Find the NPSH available and the margin at 28 m³/h.

Answer

m. m. The margin is 4.23 m, still well above the guide.

3. For the sump installation of Application 2 with cold water and a clean strainer, the suction loss at 18 m³/h is 0.277 m. Find the largest lift that leaves a margin of 1.0 m at 18 m³/h. Ignore the small change of loss with pipe length.

Answer

, so the lift is m. At sea level the same pump could lift 1.82 m more.

4. In Application 2 with cold water at 18 m³/h, the strainer slowly blocks. Find the strainer K at which the margin has fallen to 1.0 m. The velocity head is 0.05043 m, the pipe is worth 1.598 velocity heads, and the entrance and bend are worth 1.4.

Answer

The loss allowed is m, which is velocity heads. The strainer may take . A strainer K above about 21 leaves less than 1.0 m of margin.

5. A buyer proposes a 50 mm suction pipe for the sump installation, to save money: 6 m long, mm, fittings totalling 3.9, cold water. Find the velocity, the suction loss, the NPSH available and the margin at 18 m³/h.

Answer

m/s, velocity head 0.3305 m, , . Loss m. m, and the margin is m. The smaller pipe removes almost the whole margin.

References



  • I. J. Karassik, J. P. Messina, P. Cooper and C. C. Heald, Pump Handbook, 4th edition, McGraw-Hill, 2008.
  • J. F. Gülich, Centrifugal Pumps, 3rd edition, Springer, 2014.
  • F. M. White, Fluid Mechanics, 8th edition, McGraw-Hill, 2016.
  • Y. A. Çengel and J. M. Cimbala, Fluid Mechanics: Fundamentals and Applications, 4th edition, McGraw-Hill, 2018.


© 2021-2026 SiliconWit®. All rights reserved.
Predict first

At a site 1,600 m above the sea, the atmosphere can hold up a column of cold water about 8.5 m high. A pump stands 3.5 m above the water in an open sump, less than half of that height. Is the pump safe from cavitation?

See it: what the pump has and what it requires

Atmosphere
Vapour pressure
Level of the surface
Suction loss
NPSH available
NPSH required
Margin
Margin is zero at

The left bar is the NPSH available: the head of the atmosphere, less the vapour pressure head, plus or minus the level of the water surface, less the loss in the suction pipe. The right bar is the NPSH required by the booster pump of the lesson, 1.2 + 0.0042 Q². The dashed line is the required value plus the lesson's guide margin of 1.0 m. The four buttons set the lesson's cases at 18 m³/h and the site altitude of 1,600 m. Move the flow to 28 m³/h for the second column of each case. The suction pipe is 80 mm steel with an entrance, one bend and the strainer. Its length is 3 m when the surface is above the pump, and the lift plus 2.5 m when the pump is above the water, which gives the lesson's 6 m for a lift of 3.5 m. The drawing shows the levels to scale, but not the length of the pipe. Atmospheric pressure follows the standard atmosphere, and the properties of water follow the steam tables. The K values are typical, and a real blocked strainer can be far worse than 20.

lowest pressure: bubbles formpressure rises: bubbles collapse vapour pressurepressure along the path
sea levelthis site, 1,600 mstrainer blockedwater at 60 °C 1.95 m1.32 m0.26 m3.77 m guide: 1 m of margin

Check yourself

Three questions. Each wrong choice is a mistake people really make, so read the note after you answer.

1. A pump lifts cold water 3.5 m from a sump and has a margin of 3.77 m at 18 m³/h at a site on the coast. The same design is built at 1,600 m above the sea. What is the margin there?

2. On the same lift of 3.5 m at 1,600 m, the water is heated from 20 °C to 60 °C. The strainer is clean and the flow is 18 m³/h. What happens to the margin?

3. On the lift, with cold water, the strainer is blocked (K = 15). A check at the design flow of 18 m³/h gives a margin of +1.32 m, above the guide of 1.0 m. On its distribution system the pump can reach 23.34 m³/h. Is the pump safe?

Watch it build: the margin, lift of 3.5 m from the sump
Q (m³/h) NPSH (m) required 2.56 available 4.51 18 margin 1.95 m 1 m guide 26.7 the gap closes at 28:−0.36 m cavitation
  1. The maker's NPSHr rises with flow: 2.56 m at 18 m³/h, measured at a 3 % fall of head.
  2. The system gives NPSHa 4.51 m at 18 m³/h: a margin of 1.95 m.
  3. The guide asks for 1 m above NPSHr. At 18 m³/h, 1.95 m passes it.
  4. NPSHa falls and NPSHr rises with flow: they meet at 26.7 m³/h.
  5. At the largest flow, 28 m³/h, the margin is −0.36 m: the pump cavitates.
Flooded suction Suction lift tank pump 15 m water above the pump strainer pump 3.5 m open sump
The same pump with a flooded suction and with a lift (not to scale)
0 2 4 6 8 10 absolute pressure, m of water vapour pressure, 0.24 m surface, 8.53 m (83.5 kPa) pump inlet flange lowest point (blade entry) strainer, pipe, bend blades add pressure margin 1.95 m surface inlet lowest point path of the water
Absolute pressure from the liquid surface to the impeller (lift 3.5 m, 18 m³/h)
0 atmosphere, 83.5 kPa +8.53 m vapour pressure, 20 °C −0.24 m lift to the pump −3.50 m suction loss −0.28 m NPSH available 4.51 m NPSH required 2.56 m margin 1.95 m
NPSH available for a lift of 3.5 m at 18 m³/h
Found this useful?