Pressure under a column of liquid
Pressure, Head and Hydrostatics
On this page
The gauge at the pump reads 3 bar, the tank on the hill is empty, and nobody on site can say how high 3 bar will lift water. A new pump is then bought by guess, and it is either too weak to reach the tank or far larger than the work needs. The answer is one line of arithmetic. This lesson shows how pressure and height are the same quantity written in two ways, why pump makers always use height, and how to read a gauge correctly. You will calculate the pressure at a borehole pump 70 m below ground and the reading of a gauge under a storage tank. #FluidMechanics #Hydrostatics #PumpHead
Learning Objectives
By the end of this lesson, you will be able to:
- Calculate the pressure under a column of liquid, and the height of the column that a given pressure supports
- Convert between metres of water, kilopascals and bar
- Distinguish gauge pressure from absolute pressure and say which one an instrument reports
- Explain why a pump gives the same head to any liquid and a different pressure to each
- Find a liquid level from one pressure reading
Real-World System Problem: A borehole, a rising main and a tank
A school, a farm or a small factory takes its water from a borehole. The water in the ground stands 42 m below the surface. A submersible pump hangs in the borehole with its inlet 70 m below ground, so that it stays under water when the level falls during pumping. The pump pushes water through a pipe called the rising main, first up the borehole and then 450 m along the ground, to the inlet of a storage tank 18 m above ground level. A second pump, the booster, takes water from under the tank and supplies the buildings.
Before any water moves, three questions need an answer. What pressure does the pump inlet feel, deep under the water? What must a gauge at ground level read before water can reach the tank inlet? And what does a gauge under the tank read when everything is stopped? All three are about water at rest, the subject called hydrostatics.
The answers decide real purchases: the pressure rating of the pipe, the range of each gauge and transmitter, and the first estimate of the pump.
Fundamental Theory: Pressure as a height of liquid
Pressure is force on an area
Pressure is the force that a fluid applies to each unit of area of any surface it touches. The force acts at a right angle to the surface.
Here
At one point in a fluid at rest, the pressure is the same in every direction. A gauge at that point reads the same value whether its connection faces up, down or to the side.
The weight of a column of water
Think of a vertical column of water with a flat base of area
The volume of the column is
The pressure on the base is this weight divided by the area. The area cancels.
For water at 20 °C the density is
Because the area cancels, the pressure at a depth does not depend on the width of the column, the shape of the vessel or the amount of water: a 25 mm pipe and a lake both give 9.79 kPa at 1 m of depth.
Head: pressure written as a height
Turn the equation around and a pressure becomes a height:
This height is called the pressure head, or simply the head. It is the height of the column of liquid that the pressure can support. For water, a pressure of 1 bar gives
| To convert | Multiply by |
|---|---|
| metres of water to kPa | 9.79 |
| metres of water to bar | 0.0979 |
| bar to metres of water | 10.2 |
| kPa to metres of water | 0.102 |
So a gauge reading 3 bar holds
Gauge pressure and absolute pressure
The air above us has weight and presses on everything, including the water in an open tank: about 101.3 kPa at sea level. So a pressure can be stated from two different zeros.
- Absolute pressure is measured from a perfect vacuum. It can never be negative.
- Gauge pressure is measured from the atmosphere around the instrument. An ordinary gauge open to the air reads zero. It reads a negative value when the pressure is below atmospheric, which is called suction or vacuum.
The drawing puts both scales side by side for the site of this course: the gauge scale is the absolute scale moved down by the site’s atmospheric pressure, 83.5 kPa.
Most gauges and transmitters on a water system report gauge pressure. It is also what the pipe wall feels, because the air presses on the outside of the pipe too. Use gauge pressure for pipe ratings and heights of delivery. Use absolute pressure whenever the liquid may boil or a gas is compressed, because boiling depends on the true pressure in the liquid.
Drawings and data sheets may write “bar(g)” and “bar(a)”. When a number has no mark, ask which it is before you use it.
Atmospheric pressure and altitude
Atmospheric pressure is itself hydrostatic: the weight of the column of air above the place. Higher up there is less air above, so the pressure is lower: 83.5 kPa at the site of this course, about 1,600 m up, against 101.3 kPa at sea level.
Written as a head of water:
This matters for every pump that stands above its water. A pump does not pull water in. It lowers the pressure at its inlet, and the atmosphere on the water surface pushes the water in, as the air pushes a drink up a straw. That push can never support more than 8.53 m of water at this site, and in practice much less: 1.82 m less than at the coast.
A gauge does not show this loss, because it measures from the local atmosphere. The loss appears when the inlet pressure falls close to the pressure at which water boils (2.34 kPa absolute at 20 °C): vapour forms inside the pump and damages it. That subject, cavitation and net positive suction head, uses absolute pressure and the site’s 83.5 kPa throughout. A pump selected with sea-level figures has less margin at 1,600 m than its data sheet suggests.
Head as energy for each newton of liquid
Head has a second meaning that is more useful than “a height”. Lift one newton of water through one metre and you have given it one joule of energy. So a head of
This is why pump makers give head, never pressure, on their curves. The impeller of a centrifugal pump throws the liquid outward at a speed set by its diameter and its speed of rotation, and the energy it gives to each newton depends on that speed, not on the liquid. A pump that gives 30 m of head to water gives 30 m to diesel fuel, sea water or milk, at the same flow.
The pressure is a different matter, because
The pump is not at fault when it shows 2.47 bar on the lighter liquid in place of 2.94 bar on water. The lighter liquid needs less pressure for each metre, so both are lifted through the same 30 m.
A pressure reading is a level reading
Because
A transmitter at the bottom of a tank that reads 24.5 kPa gauge has
Two conditions must hold. The density must be known, which is easy for clean water. And the sensor must report gauge pressure, through a thin vent tube in its cable that carries the atmosphere to the back of the sensing element. A sealed sensor reports absolute pressure, so its reading moves with the weather: 1 kPa of change in the atmosphere looks like 0.10 m of level.
Application 1: Pressures in the borehole with the pump stopped
Step 1: Pressure at the pump inlet
Click to reveal the inlet pressure
-
Submergence. The height of water above the inlet is the depth of the inlet minus the depth of the water level.
The pump inlet is 28 m under the water surface. ✅
-
Gauge pressure. The water surface in the borehole is open to the air, so its gauge pressure is zero.
The inlet is at 274.1 kPa gauge, which is 2.74 bar. ✅
-
Absolute pressure. Add the atmosphere that presses on the water surface.
The inlet is at 357.6 kPa absolute. ✅
-
Meaning. The water at the inlet is far above its boiling pressure of 2.34 kPa absolute. A submersible pump is kept full of water by its own submergence, which is the main reason it is placed down the borehole and not at the surface. ✅
Step 2: Gauge pressure at ground level to reach the tank
Click to reveal the pressure at ground level
-
The column to support. With no flow, the gauge at ground level carries a column of water from the gauge to the tank inlet. Its vertical height is 18 m. The 450 m of pipe along the ground adds nothing. ✅
-
Pressure.
The gauge must read 1.76 bar before water stands at the tank inlet. ✅
-
Use on site. Below 1.76 bar, no water reaches the tank. With water flowing, the gauge must read more than 1.76 bar, because the moving water also loses pressure to friction in the pipe. ✅
Step 3: Head the pump must give with no flow
Click to reveal the static head and the check
-
Total lift. The pump takes water whose surface is 42 m below ground and must raise it to 18 m above ground.
The pump must give 60 m of head before one drop enters the tank. ✅
-
As a pressure.
This is the rise of pressure across the pump, from its inlet to its outlet. ✅
-
Check a second way. Calculate the outlet pressure directly. The pump outlet is 70 m below ground and the tank inlet is 18 m above ground, so the outlet carries a column of
m. The difference agrees with the 587.4 kPa of the line above (the last digit differs only by rounding), and
m. The depth of the pump cancels: lowering the pump raises its inlet and outlet pressure by the same amount. ✅
Application 2: The booster requirement and the gauge under the tank
Step 1: Convert the requirement
Click to reveal the conversion
-
To pascals.
The requirement is 293.7 kPa. ✅
-
To bar. Divide by 100.
A requirement of 30 m of head is 2.94 bar for water. The rule of 10 m for each bar would give 3.0 bar, which is 2 percent high. ✅
Step 2: The gauge reading with the pump stopped
Click to reveal the gauge reading
-
Gauge pressure. The gauge carries 15 m of water, and the tank is open to the air.
The gauge reads 1.47 bar. ✅
-
Absolute pressure at the same point.
A sealed sensor at this point would report 230.4 kPa, which is 2.30 bar. Read as if it were a gauge value, that is a level of 23.5 m in a tank that is only 15 m above the gauge. ✅
-
Check with the conversion factor.
bar. The two methods agree. ✅
Step 3: A level from the reading
Click to reveal the level
-
Head for 1.40 bar.
The water surface is 14.3 m above the gauge. ✅
-
Change of level.
m. The level has fallen by 0.7 m since the reading of 1.47 bar. ✅ -
Sensitivity. Each 0.01 bar on this gauge is 0.10 m of water. A site gauge cannot be read that finely, but a transmitter can. ✅
-
Check in the other direction. A column of 14.3 m gives
kPa, which is the 1.40 bar that was read. The Python script below prints the same 14.3 m. ✅
Verify It in Python
The script holds the two conversions as functions and repeats both applications. It then plots pressure against depth for water, in gauge and absolute terms, and for the lighter liquid.
"""Pressure and head in the water system: borehole pump inlet, rising main, booster."""import numpy as npimport matplotlib.pyplot as plt
RHO = 998.0 # kg/m3, water at 20 degCG = 9.81 # m/s2P_ATM = 83.5e3 # Pa, site at about 1,600 m altitudeP_ATM_SEA = 101.3e3 # Pa, sea levelRHO_LIGHT = 840.0 # kg/m3, a lighter liquid (typical diesel fuel)
def pressure_from_head(h, rho=RHO): """Gauge pressure in Pa under a column of liquid h metres high.""" return rho * G * h
def head_from_pressure(p, rho=RHO): """Height in metres of the liquid column that a pressure p (Pa) supports.""" return p / (rho * G)
print("Conversions for water at 20 degC")print(f" 1 m of water = {pressure_from_head(1.0) / 1e3:.2f} kPa")print(f" 1 bar = {head_from_pressure(1e5):.2f} m of water")print(f" 3 bar = {head_from_pressure(3e5):.1f} m of water")print(f" atmosphere at the site = {head_from_pressure(P_ATM):.2f} m of water")print(f" atmosphere at sea level = {head_from_pressure(P_ATM_SEA):.2f} m of water")
print("Application 1: borehole")submergence = 70.0 - 42.0p_inlet = pressure_from_head(submergence)print(f" submergence of the pump inlet: {submergence:.0f} m")print(f" inlet pressure: {p_inlet / 1e3:.1f} kPa gauge, " f"{(p_inlet + P_ATM) / 1e3:.1f} kPa absolute")p_ground = pressure_from_head(18.0)print(f" gauge at ground level to hold water at the tank inlet: " f"{p_ground / 1e3:.1f} kPa = {p_ground / 1e5:.2f} bar")print(f" head the pump must give with no flow: {42.0 + 18.0:.0f} m " f"= {pressure_from_head(60.0) / 1e5:.2f} bar")
print("Application 2: booster")p_req = pressure_from_head(30.0)print(f" 30 m of head: {p_req / 1e3:.1f} kPa = {p_req / 1e5:.2f} bar")p_tank = pressure_from_head(15.0)print(f" gauge under the half-full tank: {p_tank / 1e3:.1f} kPa " f"= {p_tank / 1e5:.2f} bar")print(f" the same point in absolute pressure: {(p_tank + P_ATM) / 1e3:.1f} kPa")print(f" level shown by a reading of 1.40 bar: {head_from_pressure(1.40e5):.1f} m")
print("Same head, different liquid")p_light = pressure_from_head(30.0, RHO_LIGHT)print(f" 30 m of head in a liquid of {RHO_LIGHT:.0f} kg/m3: " f"{p_light / 1e3:.1f} kPa = {p_light / 1e5:.2f} bar")print(f" ratio of the two pressures: {p_light / p_req:.3f}")
# ---------- Plot: pressure against depth ----------depth = np.linspace(0.0, 30.0, 61)fig, ax = plt.subplots(figsize=(7, 5))ax.plot(pressure_from_head(depth) / 1e3, depth, label="water, gauge")ax.plot((pressure_from_head(depth) + P_ATM) / 1e3, depth, "--", label="water, absolute (site)")ax.plot(pressure_from_head(depth, RHO_LIGHT) / 1e3, depth, ":", label="lighter liquid, gauge")ax.invert_yaxis()ax.set_xlabel("pressure (kPa)")ax.set_ylabel("depth below the liquid surface (m)")ax.set_title("Pressure rises in a straight line with depth")ax.grid(True, alpha=0.3)ax.legend()fig.tight_layout()fig.savefig("pressure_head_hydrostatics.png", dpi=120)print("Saved pressure_head_hydrostatics.png")Expected output
Conversions for water at 20 degC 1 m of water = 9.79 kPa 1 bar = 10.21 m of water 3 bar = 30.6 m of water atmosphere at the site = 8.53 m of water atmosphere at sea level = 10.35 m of waterApplication 1: borehole submergence of the pump inlet: 28 m inlet pressure: 274.1 kPa gauge, 357.6 kPa absolute gauge at ground level to hold water at the tank inlet: 176.2 kPa = 1.76 bar head the pump must give with no flow: 60 m = 5.87 barApplication 2: booster 30 m of head: 293.7 kPa = 2.94 bar gauge under the half-full tank: 146.9 kPa = 1.47 bar the same point in absolute pressure: 230.4 kPa level shown by a reading of 1.40 bar: 14.3 mSame head, different liquid 30 m of head in a liquid of 840 kg/m3: 247.2 kPa = 2.47 bar ratio of the two pressures: 0.842Saved pressure_head_hydrostatics.pngThe ratio 0.842 is the ratio of the two densities,
Common Mistakes
- Measuring the height along the pipe. Only the vertical distance between the two points enters
. A long horizontal pipe adds no pressure at rest. - Mixing gauge and absolute values in one calculation. Decide at the start which one you use, and convert every pressure to it. An error of one atmosphere is 8.5 m of water at this site.
- Using 101.3 kPa for the atmosphere at every site. At 1,600 m it is 83.5 kPa. Gauge calculations do not show the difference, but every calculation about boiling at a pump inlet does.
- Expecting a pump to show the same pressure on every liquid. The head is the same and the pressure follows the density. Convert a maker’s head to pressure with the density of your own liquid.
- Believing that a larger pipe or a larger tank gives more pressure at the bottom. The pressure at rest depends on the height of liquid and its density, and on nothing else.
- Reading a level from a sealed (absolute) sensor without subtracting the atmosphere, or from a vented sensor whose vent tube is blocked or wet.
Summary
- In a liquid at rest, pressure rises with depth in a straight line:
, with measured vertically. - Head is pressure written as a height of liquid,
. For water at 20 °C, 1 m is 9.79 kPa and 1 bar is 10.2 m. - Gauge pressure is measured from the local atmosphere and absolute pressure from a vacuum. They differ by the atmospheric pressure, which is 83.5 kPa at the site and 101.3 kPa at sea level.
- Head is energy for each newton of liquid. A pump gives the same head to any thin liquid and a pressure in proportion to the density.
- In the borehole at rest, the pump inlet is at 274.1 kPa gauge, the gauge at ground level must show 1.76 bar to hold water at the tank inlet, and the pump must give 60 m of head before water moves.
- A pressure reading at a known position is a level reading. The gauge under the half-full tank reads 1.47 bar.
Exercises
Use
1. A gauge on a pump outlet reads 3.0 bar with a valve closed downstream and the pipe full of water. How high above the gauge can this pressure hold water?
Answer
2. An open tank holds water 4.2 m deep at a site where the atmospheric pressure is 83.5 kPa. Find the gauge and absolute pressure on the floor of the tank.
Answer
3. A vented level transmitter hangs 70 m below ground in a borehole. With the pump running it reads 196 kPa. Find the submergence of the transmitter and the depth of the water level below ground.
Answer
4. A gauge at ground level on a rising main reads 2.2 bar with no flow. The tank inlet is 18 m above the gauge. Does the water reach the inlet, and by what margin in metres?
Answer
5. A pump gives 45 m of head at a certain flow. Find the rise of pressure across it when it pumps (a) water, and (b) brine of density
Answer
(a)
6. Find the atmospheric pressure as a head of water at the site (83.5 kPa) and at sea level (101.3 kPa). A surface pump stands 6.0 m above the water in an open sump. With the water at rest and the suction pipe full, find the absolute pressure at the pump inlet at each place.
Answer
The heads are 8.53 m and 10.35 m. The column of 6.0 m lowers the pressure by
References
- F. M. White, Fluid Mechanics, 8th edition, McGraw-Hill, 2016.
- Y. A. Çengel and J. M. Cimbala, Fluid Mechanics: Fundamentals and Applications, 4th edition, McGraw-Hill, 2018.
- I. J. Karassik, J. P. Messina, P. Cooper and C. C. Heald, Pump Handbook, 4th edition, McGraw-Hill, 2008.
Two gauges, both at ground level. One is under a thin pipe of 25 mm, full of water to 18 m above the gauge. The other is under a wide tank whose water surface is also 18 m above the gauge. Which gauge reads more?
The three vessels hold the same vertical height of liquid: a thin pipe, a wide tank and a sloping pipe. The gauge under each reads the same, because the area cancels in p = ρ g h. On the right, pressure rises in a straight line with depth. The dashed line is absolute pressure: the same line moved up by the atmosphere. Change the liquid and only the slope changes.
Check yourself
Three questions. Each wrong choice is a mistake people really make, so read the note after you answer.
1. At the site of this course (atmosphere 83.5 kPa), a sealed level sensor hangs 65 m below ground in a borehole. A sealed sensor reports absolute pressure. It reads 210 kPa. How deep below ground is the water level?
2. A pump gives 40 m of head on water, a rise of 3.92 bar. The same pump at the same speed and flow now pumps brine of density 1,150 kg/m³. What head and what pressure rise does it give?
3. At the site (1,600 m, 83.5 kPa), a farmer wants a surface pump 9 m above the water in an open well. The seller says suction pumps lift about 10 m. What happens?
- Lift 1 N of water through 1 m and it gains 1 J. A head in metres is joules for each newton.
- The pump gives each newton the same energy, so water and diesel rise the same 30 m.
- Water, 998 kg/m³: 998 × 9.81 × 30 = 293.7 kPa. The gauge reads 2.94 bar.
- Diesel, 840 kg/m³: 840 × 9.81 × 30 = 247.2 kPa. The gauge reads 2.47 bar.
- Both liquids stand 30 m high. The lighter one needs less pressure for each metre.
Discussion
No comments yet. Questions, results from your own build, a better way to explain it: all welcome.
My notes on this page
Kept on this device only. Nothing is sent anywhere.
Tip: select words in the lesson, or tap a figure or an equation, to put a note right there.
Notes on earlier wording
The lesson has changed and these words are no longer in it. Your notes are kept, with the words you chose.