Skip to content
You Start with one site
Amounts in Start with one site
Vibration & Reliability · Concept

Bathtub curve

One idea Beginner 5 min read
Found this useful?

A new pair of shoes can fail in the first week if the glue was bad. If it survives that, it gives little trouble for a long time, and at the end the sole wears through. The bathtub curve is a picture of how the chance of failure of a part changes with age: high when a part is new, low in the middle, and high again when it is old.

New means good?A new part can carry a defect, or be fitted badly.Early failures
Old means bad?Only if something in the part is used up with running hours.Wear-out
And in between?Failures come from outside events, at any age.Random failures

See it

Predict first

A part has run for 4,000 hours without trouble, and it is in the middle of its life. At a planned stop it is replaced by a new part of the same kind. What happens to the chance of a failure in the next 1,000 hours?

See it: the hazard rate of one kind of part, against its age

Kind of failure that dominates
Hazard rate, per million hours
Chance of failure in the next 1,000 hours

The dark curve is the hazard rate: of the parts that have reached an age, the share that fail in the next hour of running. It is the sum of the three dotted lines. The bars on the right show the three at the chosen age, in failures per million hours. The curve is an example, not data from a real part.

The idea

Take the parts that are still running at some age. The hazard rate is the share of them that fail in the next short period, divided by the length of that period. Parts that failed earlier are not counted, because a part in service is always a survivor.

hazard rate = failures in the period ÷ (parts at risk × length of the period)

parts at risk are the parts still running at the start of the period. The unit is failures per hour

The bathtub curve is three behaviours added together. Early failures come from defects of manufacture and mistakes of installation. The weak parts fail soon and leave, so the rate falls. Random failures come from outside events and arrive at a steady rate at every age. Wear-out comes when wear, fatigue or corrosion uses the part up, and the rate rises.

Replacing a part by age prevents failures only in wear-out. In the middle it prevents nothing, and at any age it brings back the early failures of a new part.

The curve is a way to remember the three behaviours. It does not describe every item: a simple part usually shows one region only.

One worked number

The question

1,500 identical parts start together. At 4,000 hours, 1,000 of them are still running. In the next 100 hours, 7 of those fail. What is the hazard rate at 4,000 hours?

Show the worked solution, 3 steps
  1. Count the parts at risk

    Only the survivors can fail: 1,000 parts, not the 1,500 that started.

  2. Divide the failures by parts and by time

    7 ÷ (1,000 × 100 h) = 0.00007 per hour.

  3. Write it in a unit that is easy to read

    0.00007 × 1,000,000 = 70 per million hours. This is the value the figure shows at 4,000 hours.

The mistake to avoid

Older does not always mean more likely to fail. It is true only for a part with a clear wear-out, such as a belt, a brake lining or a pump impeller. In one well known study of aircraft components, the figure commonly quoted is that only 11% of items had a failure pattern related to age. That figure belongs to that study and not to your site, but the point is general: before replacing a part by the calendar, ask what in it is used up with running hours. See the lesson on failure patterns.

Check yourself

Question 1

800 pump seals start together. At 2,000 hours, 500 are still running. In the next 200 hours, 3 of them fail. What is the hazard rate at 2,000 hours?

Question 2

The coils of a set of valves fail at random: their hazard rate is the same at every age. The site replaces all the coils at every yearly shutdown. What does this achieve?

Question 3

Twenty new drives are fitted. Four fail in the first month, and then none fail for two years. Which region is this, and what is the useful action?

Where you meet it

  • A plant after its yearly shutdownMany parts have been opened and refitted, so the first weeks after the start often bring more failures than the weeks before the stop.
  • A conveyor belt or a pump impellerThese are used up by running hours, so replacement at a chosen age prevents failures.
Key points
  • The hazard rate is the failures in a period divided by the parts still running and by the length of the period.
  • Early failures fall with age, random failures stay level, wear-out rises. The bathtub curve is their sum.
  • Replacement by age helps only in wear-out. Elsewhere it prevents nothing and brings back early failures.
  • Most items show one region, not all three.
Found this useful?

Discussion

    Comments show your name. Be kind, stay on the topic.