Capacitor
On this page
Stretch a rubber sheet across a water pipe. While the pressure rises, the sheet bulges and some water moves. When the pressure stays steady, the sheet stops moving, and so does the water. A capacitor is that sheet: it stores charge, it blocks a steady voltage, and current flows through it only while the voltage across it changes.
See it
A 100 µF capacitor has been connected across a steady 12 V supply for one hour. What current flows through it now?
Current flows only on the slopes, while the voltage changes. A faster change gives a taller, shorter pulse. The shaded area of each pulse is the charge, and it is always the same 50 µC, because the capacitor always moves from 0 V to 5 V.
The idea
A capacitor is two metal plates with a thin insulator, the dielectric, between them. Charge collects on one plate and leaves the other. Capacitance says how much charge it holds for each volt. It is measured in farads, and real parts are in microfarads (µF, millionths of a farad). A 10 µF capacitor at 5 V holds 50 millionths of a coulomb.
To change the voltage, charge must flow in or out. So a current flows only while the voltage changes, and a faster change needs a larger current:
I is the current in amperes, C the capacitance in farads, ΔV the change of voltage and Δt the time the change takes, in seconds
A steady voltage has ΔV = 0, so the current is zero: the capacitor blocks DC. An alternating voltage never stops changing, so current flows all the time. A real capacitor also leaks a very small current, and an electrolytic one has a + lead and a − lead that must not be reversed.
One worked number
The voltage across a 10 µF capacitor rises from 0 V to 5 V in 1 ms. What current flows while it rises? What current flows after it stops at 5 V?
Show the worked solution, 3 steps
- Write everything in base units
C = 10 µF = 0.000010 F. ΔV = 5 V. Δt = 1 ms = 0.001 s.
- Use the formula
I = 0.000010 × 5 ÷ 0.001 = 0.05 A = 50 mA.
- After the change
The voltage no longer changes, so ΔV = 0 and the current is 0 mA. The figure opens at this case: read the two currents.
The mistake to avoid
A second trap: a capacitor keeps its charge after the power is off. The large capacitors inside a variable speed drive or a solar inverter can hold a dangerous voltage for minutes. Only a trained person opens that equipment, after the waiting time printed on its label.
Check yourself
The voltage across a 100 µF capacitor rises by 2 V in 10 ms. What current flows while it rises?
The run capacitor of a single phase compressor in a cold room is on the 50 Hz mains. A clamp meter shows current in its wires all the time. Why?
A vibration sensor gives a steady 2.5 V with a small 0.1 V vibration signal on top. It feeds an amplifier through a capacitor in series. What reaches the amplifier?
Where you meet it
- Single phase motorsThe run capacitor of a borehole pump, a fan or a cold room compressor shifts the current in one winding so that the motor can turn.
- Power factor correctionA capacitor bank in a factory supplies the current that motors take back and forth, so the cables and the utility do not carry it.
- Drives and solar invertersA bank of large capacitors holds the DC voltage steady between the input and the output, and it holds a charge after switch-off.
- Vibration sensorsA series capacitor removes the steady part and keeps the vibration.
- A capacitor stores charge on two plates separated by an insulator.
- Current flows only while the voltage changes: I = C × ΔV ÷ Δt.
- It blocks a steady voltage and passes a changing one.
- It takes a surge at switch-on, and it can keep its charge after switch-off.
Discussion
No comments yet. Questions, results from your own build, a better way to explain it: all welcome.
My notes on this page
Kept on this device only. Nothing is sent anywhere.
Tip: select words in the lesson, or tap a figure or an equation, to put a note right there.
Notes on earlier wording
The lesson has changed and these words are no longer in it. Your notes are kept, with the words you chose.