Skip to content
You Start with one site
Amounts in Start with one site
Vibration & Reliability · Concept

Envelope analysis

One idea Advanced 5 min read
Found this useful?

A bell struck again and again by a hammer gives two things to hear: the note of the bell and the rhythm of the hammer. A small pit in a bearing is the hammer, and the bearing housing is the bell. Envelope analysis removes the note and keeps the rhythm: it follows the outline of the ringing and measures how often the blows repeat.

At the fault frequency74 Hz for this bearing.Almost nothing there yet
In the overall levelOne number for the whole machine.It hardly moves
In the ringingThousands of hertz, repeating 74 times a second.Envelope analysis finds it

See it

Predict first

A motor at 1465 rev/min has a small pit on the outer race of a bearing, which gives blows 74 times a second. In an ordinary spectrum, how large is the line at 74 Hz compared with the line at running speed?

See it: one bearing signal, filtered in a band you choose

Band
Line at BPFO
Above the background

The signal is generated on this page: blows 74.15 times a second that ring the housing at 3,200 Hz, plus running speed and noise. The filter keeps a band 1,600 Hz wide. The outline of what passes is the envelope, and its spectrum is drawn below.

The idea

Each blow makes the housing ring at its own resonance, a natural frequency of the structure, here near 3,200 Hz. The ringing dies away before the next blow. So the signal is a resonance whose size jumps up and decays again, 74 times a second.

a(t) = E(t) × cos(2π fn t)

a the acceleration, fn the resonance in Hz, E(t) the envelope: the size of the ringing at each moment

The resonance carries the message, as a radio wave carries a voice. Envelope analysis has four steps: a band-pass filter keeps only the band around the resonance, the envelope E(t) is taken, its average is removed, and the spectrum of what remains is drawn. That envelope spectrum has a line at the repetition rate and its multiples. Compare that rate with the bearing fault frequencies to name the damaged part.

A line is evidence, not proof. Check the multiples, the trend and the time waveform.

One worked number

The question

The motor runs at 24.42 Hz and its BPFO is 74.15 Hz. The envelope spectrum shows lines at 74.0, 148.5, 222.5 and 297.0 Hz. Is this the outer race, or three times running speed?

Show the worked solution, 3 steps
  1. Find the spacing

    The lines are about 74.2 Hz apart. Both BPFO (74.15 Hz) and 3 × 24.42 = 73.25 Hz are close, so the first line alone does not decide.

  2. Go to a higher multiple

    4 × 74.15 = 296.6 Hz. The shaft line nearby is 12 × 24.42 = 293.0 Hz.

  3. Compare

    297.0 Hz is 0.4 Hz from the bearing line and 4.0 Hz from the shaft line. The row follows BPFO: consistent with an outer race defect. The figure opens on this kind of row.

The mistake to avoid

An empty envelope spectrum is not a healthy bearing. If the band misses the resonance, almost nothing that repeats passes the filter. Find the band first: look for a raised hump in the acceleration spectrum, or the band that has risen most since a healthy reading. In the figure, move the band away from 3,200 Hz and watch the bearing line sink into the background.

A second trap: envelope amplitudes depend on the band, the resonance and the mounting. Compare a reading only with earlier readings at the same point and settings.

Check yourself

Question 1

On the same motor (BPFO 74.15 Hz, BPFI 121.19 Hz, cage 9.27 Hz), the filtered waveform shows bursts 8.25 ms apart. What is the repetition rate, and what does it match?

Question 2

An analyser offers a fixed envelope band of 500 to 1,500 Hz. On a motor whose housing rings near 3,200 Hz, the envelope spectrum is nearly flat. What can you conclude?

Question 3

Two instruments from different makers read envelope values of 2.1 and 0.8 on two similar pumps. Which pump has the worse bearing?

Where you meet it

  • A compressor motorAn outer race pit shows as a row of lines at BPFO months before the overall level moves.
  • A gearboxA cracked tooth strikes once per turn of its shaft, and the envelope shows that rate.
  • A slow conveyorBelow about 100 rev/min the blows are soft and few, and the method needs long records.
  • The sensorIt needs an industrial accelerometer, stiffly mounted and sampled at thousands of samples a second. A low cost sensor reading a few hundred a second cannot see the ringing.
Key points
  • Small defects put their energy in a resonance. The fault frequency is only how often the bursts repeat.
  • Filter around the resonance, take the envelope, then its spectrum.
  • Match the row of lines, not one line, to a bearing frequency.
  • The band decides the result. A flat envelope from the wrong band proves nothing.
Found this useful?

Discussion

    Comments show your name. Be kind, stay on the topic.