FMEA and the RPN
On this page
Before a long drive, a careful driver thinks of what could go wrong: a flat tyre, an empty tank, failed brakes. One of these could kill. A failure modes and effects analysis (FMEA) does this for a machine: a team lists each way it can fail and what follows, then ranks the list. The risk priority number (RPN) is the usual ranking, and it has a trap.
See it
Three failure modes of a cold store compressor are ranked by RPN. A refrigerant leak is fitted with a better alarm, and its detection score improves from 4 to 2. What happens to its place in the ranking?
Scores from 1 to 10, where 10 is the worst: S is severity, O is occurrence, D is detection (10 means the present checks would miss it). A severity of 9 or more means possible harm to people or the environment.
The idea
For each failure mode (a part and what happened to it, such as "contactor does not close"), the team writes its effect and gives three scores from 1 to 10: severity, how bad the worst reasonable effect is; occurrence, how often it happens; detection, how likely the present checks are to miss it. A high score is bad in all three.
S severity, O occurrence, D detection. The RPN runs from 1 to 1,000 and only sorts the lines of one table
The RPN is useful for a first sort. It is not a measure of risk: equal numbers come from very different dangers, and a good alarm lowers the RPN of a dangerous mode as much as a harmless one.
Rank by severity first. Put every mode that could harm people or the environment at the top, whatever its other scores, and send it to a proper safety assessment. Next come modes that stop the site, then modes a standby covers. Within each group, sort by how often and how costly.
One worked number
Refrigerant leak: S 9, O 4, D 4. Contactor does not close: S 4, O 4, D 9. Blocked condenser: S 8, O 6, D 2. Rank them by RPN, then by severity first.
Show the worked solution, 3 steps
- Multiply
Leak 9 × 4 × 4 = 144. Contactor 4 × 4 × 9 = 144. Condenser 8 × 6 × 2 = 96.
- Rank by RPN
Leak and contactor tie first, condenser third. The RPN cannot tell gas where people work from a small repair.
- Rank by severity first
Leak (9, safety), then condenser (8, stock at risk), then contactor (4). The figure opens on these scores.
The mistake to avoid
A second trap: the number looks finer than it is. The 1,000 combinations of scores give only 120 different products, and one point of honest disagreement can move a line several places.
Check yourself
Loss of compressor oil has S 7, O 5 and D 2 (an oil pressure switch stops the machine). What is its RPN?
A gas detector with a tested alarm is fitted, and the refrigerant leak's detection score falls from 4 to 1. Its RPN is now 36, the lowest in the table. Is the leak now a low priority?
A site acts on every RPN above 100. A mode scores S 10 (possible harm with no warning), O 1 and D 5. What should happen?
Where you meet it
- A cold store compressorWriting each effect out to the room finds the modes that pass around the standby, such as a single room probe.
- A hospital standby generatorFailure to start when the mains fails ranks first by severity, however rarely it occurs.
- A maintenance planEach high line gets an action, a name and a date. A table with no actions has changed nothing.
- An FMEA lists each failure mode, its effect, and three scores: severity, occurrence, detection.
- RPN = S × O × D sorts a long list. It is not a measure of risk.
- Equal RPNs can hide very different dangers, and good detection does not make a mode less dangerous.
- Rank by severity first: safety and environment at the top, then by consequence and cost.
Discussion
No comments yet. Questions, results from your own build, a better way to explain it: all welcome.
My notes on this page
Kept on this device only. Nothing is sent anywhere.
Tip: select words in the lesson, or tap a figure or an equation, to put a note right there.
Notes on earlier wording
The lesson has changed and these words are no longer in it. Your notes are kept, with the words you chose.