IV curve and maximum power point
On this page
A cyclist on a hill can push hard in a high gear and hardly move, or spin fast in a low gear with no force on the pedals. The most power comes from one gear in between. A solar module is the same. The IV curve is the line of every pair of current and voltage the module can give, and the maximum power point is the one place on it where their product is largest.
See it
The label of a solar module gives an open-circuit voltage of 49.9 V and a short-circuit current of 13.9 A. What is the most power the module can give in full sun?
The dark line is the IV curve of a 550 W module at 1,000 W/m² and 25 °C. The gold line is the power at each voltage. The shaded rectangle has the voltage as its width and the current as its height, so its area is the power. The dashed line from the corner is the load: a steeper line is a smaller resistance.
The idea
Join the two terminals of a module with a wire and the largest current flows, the short-circuit current Isc. The voltage is zero, so the power is zero. Leave the terminals open and the voltage rises to its largest value, the open-circuit voltage Voc. No current flows, so the power is zero again.
Between the two ends the module gives power. The current stays close to Isc over most of the range, then falls steeply near Voc. This bend is called the knee.
P in watts, V in volts, I in amperes, all at the same point of the curve
The power is largest at one point near the knee, the maximum power point, with voltage Vmp and current Imp. The module does not choose its point. The load does: a resistor of R ohms holds the module where V ÷ I = R.
The curve is not fixed. Less light lowers the current and more heat lowers the voltage, so the maximum power point moves all day. With shade on part of a module the power curve can have more than one top.
One worked number
A module has Isc = 13.9 A, Vmp = 41.9 V and Imp = 13.1 A. In full sun it is connected to a heater of 1 Ω and settles at 13.86 V. What power does the heater receive, and what share is that of the most the module can give?
Show the worked solution, 3 steps
- Find the current
I = V ÷ R = 13.86 V ÷ 1 Ω = 13.86 A.
- Find the power
P = 13.86 V × 13.86 A = 192 W.
- Compare with the maximum
The most is Vmp × Imp = 41.9 × 13.1 = 549 W, which the label rounds to 550 W. 192 ÷ 550 = 35%. The figure opens on this case. Press the button for 3.19 Ω to see the load that takes all of it.
The mistake to avoid
No fixed load stays at the best point, because the point moves. Holding it is the work of a maximum power point tracker inside a charge controller or an inverter.
Check yourself
The same module is held at 20 V, where its current is 13.85 A. What power does it give?
A technician measures 49.9 V at the open terminals of a module and 13.9 A through a short circuit. The report says: this module gives 694 W. What is wrong?
A load pulls the module 6 V above its maximum power point, from 42 V to 48 V. The current there is 5.75 A. What happens to the power?
Where you meet it
- A solar charge controllerIt changes the voltage it asks of the array many times a second, to stay at the top of the power curve as the light changes.
- A string of modules on a roofA measured IV curve with a leaning knee or a step in it points to a bad connection or a shaded module.
- Power = V × I. It is zero at both ends of the curve and largest at one point near the knee.
- The load decides the operating point. Only the right load takes the full power.
- Voc × Isc is not the power of the module.
Discussion
No comments yet. Questions, results from your own build, a better way to explain it: all welcome.
My notes on this page
Kept on this device only. Nothing is sent anywhere.
Tip: select words in the lesson, or tap a figure or an equation, to put a note right there.
Notes on earlier wording
The lesson has changed and these words are no longer in it. Your notes are kept, with the words you chose.