Performance ratio
On this page
A farmer who harvests less in a dry year has not become a worse farmer. To judge the farmer, compare the harvest with what the rain allowed. A solar plant is judged the same way. Its performance ratio is the energy it delivered, as a share of what the sunlight on its modules allowed.
See it
A solar array delivered 19% more energy in January than in April. A light sensor beside the modules shows that January had 24% more sunlight than April. In which month did the plant work better?
One year of a 9.9 kWp array on a workshop roof. The outline of each bar is the reference energy: what a loss-free array would have given in that month's light. The filled part is what the inverter delivered. The height of a bar follows the weather. The filled share follows the health of the plant.
The idea
The nameplate power of an array, Pstc, is its output under a test light of 1,000 W/m². The insolation H is the light energy that fell on each square metre of the modules in the period, in kWh/m². One kWh/m² is one hour of the test light, a peak sun hour. So an array with no losses would give Pstc × H. This is the reference energy.
Eac is the energy at the inverter output in kWh, Pstc is in kWp, H is in kWh/m². PR has no unit
The light is in the lower part of the fraction, so a cloudy month and a sunny month of a healthy plant give nearly the same value. That is the whole use of the ratio.
It is not perfectly steady. Hot cells give less, so a hot month reads a little lower than a cool one. Judge a plant against its own history, not against another site.
One worked number
A 9.9 kWp array delivered 1,204 kWh in April. A sensor fixed beside the modules, at the same tilt, recorded 151.5 kWh/m² in the same month. What is the performance ratio?
Show the worked solution, 3 steps
- Find the reference energy
9.9 kWp × 151.5 kWh/m² = 1,500 kWh. A loss-free array would have given this.
- Divide the real energy by it
PR = 1,204 ÷ 1,500 = 0.803.
- Say what it means
About 80% of the reference energy arrived, and 296 kWh did not. The figure opens on April. Move to January: more energy, and a lower ratio of 0.771.
The mistake to avoid
A second trap is the light measurement. It must come from a sensor in the plane of the modules, for exactly the same period as the energy. Light taken from a weather table, or from a sensor lying flat, gives a ratio that means nothing.
Check yourself
A 50 kWp array delivered 6,000 kWh in a month in which 160 kWh/m² fell on its modules. What is its performance ratio?
In a cloudy month the energy of a plant falls by 30%. Its performance ratio is 0.79, the same as in the sunny month before. What does this say?
An owner reads a performance ratio of 0.80 and asks the installer to find and repair the missing 20%. What is the right reply?
Where you meet it
- A rooftop solar plantThe monthly ratio falls week by week in dry weather as dust settles, and returns after rain.
- A plant with a hidden faultA failed string cuts the ratio at once, in any weather, while the energy alone could pass for a cloudy month.
- A supply contractA builder can promise a performance ratio. Nobody can promise the weather, so nobody can fairly promise the energy.
- Performance ratio = energy delivered ÷ (nameplate power × light on the modules).
- It removes the weather, so it shows the health of the plant.
- A healthy plant is commonly between 0.75 and 0.85. Below 1 is normal.
- Compare a plant with its own history, using light measured in the plane of its modules.
Discussion
No comments yet. Questions, results from your own build, a better way to explain it: all welcome.
My notes on this page
Kept on this device only. Nothing is sent anywhere.
Tip: select words in the lesson, or tap a figure or an equation, to put a note right there.
Notes on earlier wording
The lesson has changed and these words are no longer in it. Your notes are kept, with the words you chose.