Skip to content
You Start with one site
Amounts in Start with one site
Solar & Batteries · Concept

Performance ratio

One idea Intermediate 5 min read
Found this useful?

A farmer who harvests less in a dry year has not become a worse farmer. To judge the farmer, compare the harvest with what the rain allowed. A solar plant is judged the same way. Its performance ratio is the energy it delivered, as a share of what the sunlight on its modules allowed.

Compare the energy?Energy mixes the weather with the health of the plant.Rewards sunny months
Compare with a forecast?A forecast describes an average year, not this month.Blames the plant for cloud
Compare with the light that arrived?Energy out, divided by what that light allowed.The performance ratio

See it

Predict first

A solar array delivered 19% more energy in January than in April. A light sensor beside the modules shows that January had 24% more sunlight than April. In which month did the plant work better?

See it: twelve months of one array, against what the light allowed

The light allowed
The plant delivered
Performance ratio

One year of a 9.9 kWp array on a workshop roof. The outline of each bar is the reference energy: what a loss-free array would have given in that month's light. The filled part is what the inverter delivered. The height of a bar follows the weather. The filled share follows the health of the plant.

The idea

The nameplate power of an array, Pstc, is its output under a test light of 1,000 W/m². The insolation H is the light energy that fell on each square metre of the modules in the period, in kWh/m². One kWh/m² is one hour of the test light, a peak sun hour. So an array with no losses would give Pstc × H. This is the reference energy.

PR = Eac ÷ (Pstc × H)

Eac is the energy at the inverter output in kWh, Pstc is in kWp, H is in kWh/m². PR has no unit

The light is in the lower part of the fraction, so a cloudy month and a sunny month of a healthy plant give nearly the same value. That is the whole use of the ratio.

It is not perfectly steady. Hot cells give less, so a hot month reads a little lower than a cool one. Judge a plant against its own history, not against another site.

One worked number

The question

A 9.9 kWp array delivered 1,204 kWh in April. A sensor fixed beside the modules, at the same tilt, recorded 151.5 kWh/m² in the same month. What is the performance ratio?

Show the worked solution, 3 steps
  1. Find the reference energy

    9.9 kWp × 151.5 kWh/m² = 1,500 kWh. A loss-free array would have given this.

  2. Divide the real energy by it

    PR = 1,204 ÷ 1,500 = 0.803.

  3. Say what it means

    About 80% of the reference energy arrived, and 296 kWh did not. The figure opens on April. Move to January: more energy, and a lower ratio of 0.771.

The mistake to avoid

A performance ratio below 1 is not a fault. Every real plant loses energy to hot cells, dust, wiring and the inverter. Well-built plants commonly report 0.75 to 0.85 over a year. A fault is a value far below the plant's own usual one. In the figure, September falls to 0.458, close to half, because one of the two strings of modules had stopped.

A second trap is the light measurement. It must come from a sensor in the plane of the modules, for exactly the same period as the energy. Light taken from a weather table, or from a sensor lying flat, gives a ratio that means nothing.

Check yourself

Question 1

A 50 kWp array delivered 6,000 kWh in a month in which 160 kWh/m² fell on its modules. What is its performance ratio?

Question 2

In a cloudy month the energy of a plant falls by 30%. Its performance ratio is 0.79, the same as in the sunny month before. What does this say?

Question 3

An owner reads a performance ratio of 0.80 and asks the installer to find and repair the missing 20%. What is the right reply?

Where you meet it

  • A rooftop solar plantThe monthly ratio falls week by week in dry weather as dust settles, and returns after rain.
  • A plant with a hidden faultA failed string cuts the ratio at once, in any weather, while the energy alone could pass for a cloudy month.
  • A supply contractA builder can promise a performance ratio. Nobody can promise the weather, so nobody can fairly promise the energy.
Key points
  • Performance ratio = energy delivered ÷ (nameplate power × light on the modules).
  • It removes the weather, so it shows the health of the plant.
  • A healthy plant is commonly between 0.75 and 0.85. Below 1 is normal.
  • Compare a plant with its own history, using light measured in the plane of its modules.
Practice

Found this useful?

Discussion