Vibration & Reliability · Concept

P-F interval

One idea Intermediate 5 min read
Found this useful?

A tyre with a slow leak looks a little soft for days before it is flat. Look at your tyres every morning and you will catch it. Look once a month and you will not. The P-F interval is that time of warning: from the first sign of a fault that can be detected (P) to the failure (F). It sets how often you must look.

Check more often?That depends on how much warning the fault gives.Cannot be answered yet
How much warning?By ear, about 1 week. By a vibration reading, about 8 weeks.The P-F interval
Then how often?Less than the warning, with enough time left to act.Set by the P-F interval

See it

Predict first

A technician listens to a conveyor bearing on the first Monday of every month. A failing bearing can be heard for about 1 week before it seizes. Of many such faults, what share will the monthly round hear before the failure?

See it: one fault, and the visits that may find it

P-F interval
Time left in the worst case
Faults caught in time

The curve is the condition of one bearing. P is where the chosen method can first find the fault, and F is the failure. The marks below are the visits, drawn for the worst case: the fault first shows just after a visit. The shaded strip is the 1 week this site needs to get a part and plan a stop.

The idea

Many faults start small and grow while the machine still works: wear, a crack, a contact that heats. P (potential failure) is the point where a chosen method can first detect the fault. F (functional failure) is the point where the item no longer does its work. A sensitive method has an early P, so it has a longer P-F interval.

In the worst case the fault first shows just after a visit. It then waits one full task interval, the time between visits, before anyone sees it. What remains is the nett P-F interval.

nett P-F interval = P-F interval − task interval

all three in the same unit of time. The nett P-F interval must be longer than the time needed to act

A common rule sets the task interval at half the P-F interval. The P-F interval is not the same every time, so plan with the shortest one seen.

One worked number

The question

A vibration reading can find a bearing fault 8 weeks before the failure. Readings are taken every 4 weeks. The site needs 1 week to get the part and plan a stop. In the worst case, how much time is left when the fault is found? What is the longest interval that still leaves time to act?

Show the worked solution, 3 steps
  1. Take the worst case

    The fault first shows just after a reading, and waits 4 weeks for the next one.

  2. Find the time that is left

    Nett P-F interval = 8 − 4 = 4 weeks. The site needs 1 week, so this is enough.

  3. Find the longest interval

    The interval must leave 1 week: 8 − 1 = 7 weeks. Check it in the figure: at 8 weeks some faults are found on the day of the failure.

The mistake to avoid

How often to inspect is not set by how often the machine fails, or by how important it is. It is set by how fast the fault grows. A bearing that fails once in ten years and one that fails every year need the same interval if both give 8 weeks of warning. The importance of the machine decides only whether the inspection is worth its cost.

Check yourself

Question 1

An oil sample from a gearbox shows wear particles 6 weeks before the gearbox fails. The site needs 2 weeks to get the part and plan a stop. What is the longest time between samples that always leaves enough time?

Question 2

Two conveyors use the same bearing. On conveyor A it has failed once in ten years. On conveyor B it fails every year. Both give 8 weeks of warning on a vibration reading. Which conveyor needs readings more often?

Question 3

A signal lamp works and then, in one moment, does not. How often must it be inspected to find the fault before the failure?

Where you meet it

  • A conveyor or fan bearingA vibration reading gives weeks of warning where the ear gives days, so the round can be monthly.
  • An electrical connectionA loose joint runs warm for weeks before it fails, and a thermal camera survey by a qualified person finds it.
  • A fixed vibration sensorIt reads every hour and finds the fault only when the reading passes its alarm level, so a high alarm level removes most of the warning.
Key points
  • The P-F interval is the time from the first detectable sign (P) to the failure (F). It depends on the method.
  • Nett P-F interval = P-F interval − task interval. It must be longer than the time needed to act.
  • The speed of the fault sets the interval. The failure rate and the importance of the machine do not.
  • A fault with no warning cannot be caught by inspection.