State of charge
On this page
The fuel gauge of a car shows how full the tank is, as a share of a full tank. A battery needs the same number, and it has no float to read it with. State of charge (SoC) is the charge that is in a battery now, as a share of the charge it can hold: 100% is full and 0% is empty.
See it
A lithium iron phosphate battery rests at 53.1 V when it is 80% full. It is discharged to 40% and left to rest. By how much has its voltage fallen?
The battery holds 300 Ah. The curve is its voltage after a rest with no current, and it is an example of the usual shape, not the data of one product. The shaded strip covers every state of charge whose voltage is within 0.1 V of the reading, so a voltmeter cannot tell them apart.
The idea
A battery stores charge, counted in ampere hours (Ah): 300 Ah means 30 A for ten hours. The state of charge is the charge in it now divided by that capacity.
No instrument can look inside a cell and read it. A battery monitor counts. It measures the current into and out of the battery and adds it up over time. This is called coulomb counting.
I the current in amperes, positive on charge and negative on discharge. t the time in hours. C the capacity in Ah. Multiply the fraction by 100 for percent
The voltage seems a simpler gauge, and for a lithium iron phosphate battery it is a poor one. From about 20% to 80% the resting voltage is almost level. That is good for the load, which receives a steady voltage, and bad for the gauge.
The count has its own limit. A small error of the current sensor is added every hour of every day, so the count drifts until something corrects it.
One worked number
A battery of 300 Ah is at 80%. A load then takes 30 A from it for 4 hours. What is its state of charge, and how much charge is left?
Show the worked solution, 3 steps
- Count the charge taken out
30 A × 4 h = 120 Ah.
- Write it as a share of the capacity
120 Ah ÷ 300 Ah = 0.40, which is 40%.
- Subtract from the start
80% − 40% = 40%, and 0.40 × 300 Ah = 120 Ah is left. In the figure, move the slider from 80% to 40%: the resting voltage falls by only 0.56 V.
The mistake to avoid
A second trap is to trust the count for weeks. A monitor corrects itself at full charge, which the voltage does show clearly. A battery that seldom reaches full shows a number that has drifted. The lesson on batteries and state of charge follows one battery through a day.
Check yourself
A battery of 200 Ah is at 90%. It supplies 25 A for 4 hours. What is its state of charge now?
A lithium iron phosphate battery has rested for an hour and a good voltmeter reads 52.6 V. The owner says: the voltage is normal, so the battery is nearly full. What can the reading tell you?
The current sensor of a 300 Ah battery reads 0.2 A too high, all the time. The battery does not reach full charge for 10 days. How wrong is the state of charge on the display after those 10 days?
Where you meet it
- A solar battery in a workshop or a clinicThe inverter starts the generator and stops the loads by the state of charge that the battery reports.
- The backup battery of a telecom siteThe hours of backup that remain are found from the state of charge and the load.
- State of charge is the charge in the battery now, as a share of its capacity.
- It is found by counting: SoC = SoC at the start + (I × t) ÷ C.
- The resting voltage of a lithium iron phosphate battery is almost level from 20% to 80%, so voltage is a poor gauge.
- The count drifts and needs a full charge to correct it.
Discussion
No comments yet. Questions, results from your own build, a better way to explain it: all welcome.
My notes on this page
Kept on this device only. Nothing is sent anywhere.
Tip: select words in the lesson, or tap a figure or an equation, to put a note right there.
Notes on earlier wording
The lesson has changed and these words are no longer in it. Your notes are kept, with the words you chose.