Control, Measurement & Energy · Course

MTBF, MTTR and Availability

Lesson 2 of 10 24 min read
Found this useful?

A supplier’s data sheet says the MTBF is 50,000 hours, the buyer reads “it will last almost six years”, and the first unit fails in month four. A manager hears that the plant has an availability of 99.8 percent, and the same week stock is lost because both compressors stopped together. A site has two failures in a year, calculates an MTBF, and builds a spares budget on a number that could be wrong by a factor of ten. Nobody lied: the numbers were correct and were asked to say more than they can. This lesson shows what MTBF, MTTR and availability mean, how to calculate them from a record, and how far to trust them. #MTBF #Availability #Reliability

Learning Objectives

By the end of this lesson, you will be able to:

  1. Calculate MTBF, MTTR and availability from a record of failures and repairs
  2. Explain why the MTBF is not a life, and find the probability of running a stated time without failure
  3. Distinguish inherent availability from operational availability and say which one a number is
  4. Calculate a confidence interval for an MTBF that comes from a small number of failures
  5. Combine units in series and in parallel, and show how a shared cause limits the gain from a standby unit

Real-World System Problem: Two compressors and one cold room



The cold store of this course has two refrigeration compressors, one on duty and one on standby. In normal weather one compressor can hold the load, so when the duty compressor fails the standby takes over and the stock stays cold. In the hottest weeks both may be needed, and then there is no standby.

The owner asks three questions: how often does a compressor fail, how long is it out of service each time, and how much of the year is the store without cooling? The maintenance log holds five years of failures for one compressor, with the running hours at each failure and the hours to return it to service.

The first two questions lead to the MTBF and the MTTR. The third leads to availability, and it has a trap: the two compressors look like two independent chances, but they hang on one electrical supply and reject their heat through one condenser.

CondenserElectrical supplyCompressor 2(standby)Compressor 1(duty)sharedsharedCold room
The refrigeration plant: two compressors, shared items

Fundamental Theory: Three numbers from a record



Up time and down time

A repairable machine runs (up), fails, is repaired (down), and runs again.

updownTBF₁TTR₁TBF₂TTR₂TBF = running time between failuresTTR = time to return to service
The record of a repairable machine

The mean of the running times is the MTBF; the mean of the down times is the MTTR.

MTBF: mean time between failures

For a repairable item, add all the running hours in the record and divide by the number of failures:

The inverse is the failure rate, , in failures per hour. Use running hours, not calendar hours: a standby machine that runs 500 hours a year has not had 8,400 hours in which to fail by wear or load. For an item that is thrown away, not repaired (a lamp, a bearing, a fuse), the same idea is the mean time to failure, MTTF.

The simple division is fully meaningful when the failure rate is constant: failures arrive at random and the machine gets neither better nor worse. If the rate changes, the MTBF is still the average of the record, but it describes neither its start nor its end.

What the MTBF does not mean

With a constant failure rate, the probability of running for a time without failure is

Put and the result is : only 37 percent of runs last as long as the MTBF, and 63 percent end before it.

Times between random failures are very unequal: many short ones and a few very long ones. The long ones pull the mean up, as a few large salaries pull a mean salary above what most people earn. The median time between failures is .

So an MTBF of 50,000 hours is not a promise of 50,000 hours. It is a failure rate of 1 in 50,000 per hour, written the other way up. Of 100 such units running all year (8,760 hours), is expected to fail in the first year: about 16 units. An early failure does not prove the data sheet false.

MTTR: mean time to repair

The MTTR is the mean of the down times. The difficulty is in what the down time includes. A stop of ten hours may contain forty minutes of work with tools.

failurerunningwaitingdiagnosiswaitingrepairrestartfor thefor theand testpersonpartdowntimeofthestop
What one stop is made of

A repair time that counts only diagnosis and hands-on work measures the machine and the skill of the technician. One that counts from the stop to the restart measures the whole organisation: how fast the fault is noticed, whether a person is on site, whether the part is on the shelf. Both are useful. Always state which one an MTTR is.

Repair times are also unequal: most are short and a few very long (the part that had to come from another country). Use the mean to calculate total downtime, and report the median and the longest beside it to show a typical stop and a bad one.

Availability and its two meanings

Availability is the fraction of the time that the machine is able to do its duty.

Steady-state availability

It is the up time divided by the up time plus the down time, over a record long enough to hold many failures.

The value depends on which MTTR goes in, and so availability has two common meanings.

  • Inherent availability uses only the active repair time (diagnosis, repair, restart). It describes the equipment as designed, with a perfect supply of people and parts.
  • Operational availability counts all the down time that the site really had: waiting, logistics and, in the full form, planned maintenance stops too.

Take a pump with an MTBF of 6,000 hours and an active repair time of 5 hours. Its inherent availability is : 7 hours down in a year of 8,400 hours. If each stop also waits 43 hours for a part, the mean down time is 48 hours and the operational availability is : 67 hours a year. The machine is the same; the store room is different.

A supplier quotes inherent availability, which the supplier controls. An owner lives with operational availability. A number with no label is usually the more flattering one.

Availability also hides the pattern of the down time: 0.998 can be one stop of 17 hours a year or 100 stops of 10 minutes. A cold room survives the second and not the first. Always give the failure rate and the repair time beside the availability.

The uncertainty of an MTBF from few failures

A record with 9 failures is a small sample. Run the same machine for the same five years again, and chance alone might give 5 failures or 14, with the MTBF moving to match. An honest report gives a range.

For a constant failure rate, the number of failures in a fixed time follows the Poisson distribution, which gives an exact interval through the chi-square distribution. Let be the total running hours, the number of failures, and the confidence level (for 90 percent, ). For a record that ends at a fixed time (the usual case: “the last five years”):

Confidence interval for the MTBF, record ended at a fixed time

is the value that a chi-square variable with degrees of freedom stays below with probability . In Python it is scipy.stats.chi2.ppf(p, k).

If the record ends exactly at a failure, both limits use degrees of freedom. The difference matters only for very small .

Three things to know about this interval:

  • It is not symmetric. The upper limit is much further from the estimate, because a short record cannot rule out a very good machine.
  • Its width depends on the number of failures, not on the hours. Ten years with 3 failures tell you less than two years with 30.
  • A record with no failures still gives a lower limit. With the one-sided form is , which for 90 percent confidence is . A full year with no failure supports only the statement that the MTBF is above 3,648 hours.

The interval covers only the scatter of chance under a constant rate, not a changing rate, incomplete records, or a failure never written down.

Units in series

Units are in series, in the reliability sense, when the system needs all of them: a conveyor needs its motor, its gearbox and its belt. The system is up only when every unit is up, so for units that fail independently the availabilities multiply:

The same rule holds for reliability over a mission time: , and constant failure rates in series add. A series system is always worse than its worst unit: 0.995, 0.990 and 0.985 give 0.970.

Units in parallel

Units are in parallel when either one can do the whole duty. The system is down only when both are down. For two independent units with unavailabilities and :

BeltMotorGearboxCompressor 2Compressor 1SeriesParallel
Series: all are needed. Parallel: one is enough

Two units each down 1 percent of the time give, by this formula, a system down 0.01 percent of the time. That large gain is the reason for a standby, and the place where the arithmetic is most often wrong.

Common-cause failure

The parallel formula multiplies two probabilities, which is correct only if the two units fail independently. In a real plant they share things. A shared thing that fails stops both units in the same moment, and redundancy inside the pair cannot help. This is a common-cause failure.

Typical shared causes are:

  • one electrical supply, one control panel or one control power circuit,
  • one condenser, one cooling water line, one oil or refrigerant system,
  • one environment (a heat wave, a flood, dust),
  • one maintenance team making the same error on both units on the same day,
  • one design or one batch of parts with the same defect.

A shared item is in series with the parallel pair:

Once the pair is good, the shared items decide the result. A standby has one more limit: it must start when called. A standby idle for months can hold a fault nobody has seen, because nothing asked it to run.

Application 1: Five years of one compressor



Step 1: MTBF and failure rate

Click to reveal the calculation
  1. MTBF.

    ✅

  2. Failure rate. per hour, which is failures a year. ✅

  3. Look at the times, not only the mean. The running hours between failures were 7,759, 383, 1,995, 612, 51, 6,965, 7,053, 561 and 8,802. Five of the nine are less than half the MTBF, and the other four are well above it. A mean of 4,667 hours describes no single run. ✅

  4. A year with no failure. . Only about one year in six passes without a failure of this compressor. The chance of running one full MTBF without failure is . ✅

Step 2: MTTR, availability and downtime

Click to reveal the calculation
  1. MTTR. The nine down times add to 78.8 hours.

    The median is 8.2 hours and the longest is 12.0 hours. This MTTR counts from stop to restart, with all waiting. ✅

  2. Availability.

    This is an operational availability for unplanned stops only, because the down times include the waiting and the record has no planned stops. ✅

  3. Downtime a year. The unavailability is , and hours a year. Directly from the record, hours a year. The small difference is that the formula divides by running hours plus down hours. ✅

  4. Read it as events. Not 15.7 hours spread thinly through the year, but about 1.8 stops a year of about 9 hours each. ✅

Step 3: A 90 percent confidence interval for the MTBF

Click to reveal the calculation
  1. Set up. h, , . The record ends at a fixed time (the end of year five), so the lower limit uses degrees of freedom and the upper limit uses . ✅

  2. Chi-square values. From scipy, and . ✅

  3. Limits.

    With 90 percent confidence the MTBF is between 2,674 and 8,945 hours. ✅

  4. As failures a year. and . The record supports any rate from about 1 to about 3 failures a year. ✅

  5. Effect on availability. With the MTTR held at 8.76 hours, the availability at the two ends is 0.99674 and 0.99902: 27.4 and 8.2 hours of downtime a year. ✅

Step 4: Check against the true value and against other record lengths

Click to reveal the check
  1. The true value. The record was generated with a true rate of 1.6 failures a year, an MTBF of hours. The estimate of 4,667 hours is 11 percent low, and the interval of 2,674 to 8,945 hours contains the true value, as it should nine times in ten. ✅

  2. A shorter record. A record of 2 failures in one year gives an MTBF of 4,200 hours with an interval of 1,334 to 23,638 hours. The upper limit is 17.7 times the lower. Such a number cannot support a decision. ✅

  3. A longer record. A record of 36 failures in twenty years gives the same 4,667 hours with an interval of 3,534 to 6,285 hours, a ratio of 1.8. To halve the width of the interval, the record needs about four times as many failures. ✅

Application 2: What the standby compressor adds



Step 1: Two independent compressors

Click to reveal the calculation
  1. One compressor. , which is 15.7 hours a year. ✅

  2. Both down together.

    ✅

  3. Availability of the pair. . In a year that is minutes without cooling. ✅

  4. The gain on paper. The standby divides the downtime by . ✅

Step 2: The same pair with a shared supply and condenser

Click to reveal the calculation
  1. Shared items. and . ✅

  2. System. The shared items are in series with the pair.

    ✅

  3. Downtime. hours a year without cooling: 4 hours from the supply, 6 hours from the condenser, and 0.03 hours from the two compressors together. The shared items cause 99.7 percent of it. ✅

  4. The real gain. One compressor on the same shared items would be down hours a year. The standby reduces that to 10.03 hours, a factor of 2.6 and not 534. ✅

Step 3: A standby that must start

Click to reveal the calculation
  1. Calls on the standby. The duty compressor fails 1.80 times a year, so the standby is called 1.80 times a year. ✅

  2. Calls that find no standby. a year, which is once in 11.1 years on average. ✅

  3. Expected failure cost with no standby fitted. currency units a year. ✅

  4. With a perfect standby. currency units a year. ✅

  5. With the standby as stated.

    currency units a year. ✅

Step 4: Check with limiting cases

Click to reveal the check
  1. Perfect shared items. Set both shared availabilities to 1 and the system value returns to 0.9999965, the independent pair of Step 1. ✅

  2. A standby that never starts. Set the start probability to 0 and the cost of Step 3 becomes , the value with no standby. Set it to 1 and it becomes 270,000. The stated case of 290,700 lies between them, near the good end. ✅

Verify It in Python



The script generates the compressor record, calculates the three numbers, the confidence interval and the standby case, and saves a plot of the record and of how the interval narrows as failures accumulate.

availability.py
"""MTBF, MTTR and availability from a failure record, with a confidence interval and a standby unit."""
import numpy as np
from scipy.stats import chi2
import matplotlib.pyplot as plt
YEAR = 8400.0 # running hours in a year at the site
def compressor_events(seed=8, years=5):
"""Failures of one compressor over five years: time of failure and hours of repair."""
rng = np.random.default_rng(seed)
hours = years * YEAR
n = rng.poisson(1.6 * years)
t = np.sort(rng.uniform(0.0, hours, n)).round(0)
repair = rng.lognormal(np.log(9.0), 0.8, n).round(1)
return t, repair
def mtbf_interval(total_hours, n, confidence=0.90):
"""Two-sided interval for the MTBF of a constant-rate item, record ended at a fixed time."""
a = 1.0 - confidence
lower = 2.0 * total_hours / chi2.ppf(1.0 - a / 2.0, 2 * n + 2)
upper = 2.0 * total_hours / chi2.ppf(a / 2.0, 2 * n)
return lower, upper
# ---------- Application 1: one compressor, five years ----------
t, repair = compressor_events()
T = 5 * YEAR
n = t.size
mtbf = T / n
mttr = repair.mean()
lam = 1.0 / mtbf
A = mtbf / (mtbf + mttr)
print("Application 1: one compressor, five years of record")
print(f" failures at (h): {t.astype(int).tolist()}")
print(f" repair times (h): {repair.tolist()}")
print(f" hours between failures: {np.diff(np.concatenate([[0.0], t])).astype(int).tolist()}")
print(f" {n} failures in {T:.0f} h: MTBF {mtbf:.0f} h, {lam * YEAR:.2f} failures a year")
print(f" total repair {repair.sum():.1f} h, MTTR {mttr:.2f} h, "
f"median {np.median(repair):.1f} h, longest {repair.max():.1f} h")
print(f" availability {A:.5f} ({100 * A:.3f} %), unavailability {1 - A:.5f}")
print(f" downtime a year: {(1 - A) * YEAR:.1f} h from the availability, "
f"{repair.sum() / 5:.1f} h from the record")
print(f" survive to the MTBF: {np.exp(-1.0):.3f}, a year with no failure: "
f"{np.exp(-lam * YEAR):.3f}")
lo, hi = mtbf_interval(T, n)
print(f" chi-square values: {chi2.ppf(0.95, 2 * n + 2):.2f} (20 degrees of freedom), "
f"{chi2.ppf(0.05, 2 * n):.2f} (18)")
print(f" 90 % interval for the MTBF: {lo:.0f} to {hi:.0f} h")
print(f" as failures a year: {YEAR / hi:.2f} to {YEAR / lo:.2f}")
A_lo, A_hi = lo / (lo + mttr), hi / (hi + mttr)
print(f" availability at the ends of the interval: {A_lo:.5f} to {A_hi:.5f}, "
f"downtime {(1 - A_hi) * YEAR:.1f} to {(1 - A_lo) * YEAR:.1f} h a year")
for k, years in ((2, 1), (9, 5), (36, 20)):
l2, h2 = mtbf_interval(years * YEAR, k)
print(f" a record of {k:2d} failures in {years:2d} {'year' if years == 1 else 'years'}: MTBF {years * YEAR / k:.0f} h, "
f"interval {l2:.0f} to {h2:.0f} h (ratio {h2 / l2:.1f})")
zero = 2.0 * YEAR / chi2.ppf(0.90, 2)
print(f" a year with no failure at all: 90 % sure only that the MTBF is above {zero:.0f} h")
# ---------- Application 2: duty and standby ----------
U = 1.0 - A
print("Application 2: duty and standby compressors")
print(f" one compressor: unavailability {U:.6f}, {U * YEAR:.1f} h a year")
U_pair = U * U
print(f" two independent compressors: unavailability {U_pair:.3e}, "
f"availability {1 - U_pair:.7f}, {U_pair * YEAR * 60:.1f} min a year")
print(f" gain from the standby if independent: {U / U_pair:.0f} times")
H_POWER, H_COND = 4.0, 6.0 # shared items: hours a year out of service
A_power, A_cond = 1.0 - H_POWER / YEAR, 1.0 - H_COND / YEAR
A_sys = A_power * A_cond * (1.0 - U_pair)
print(f" shared supply {A_power:.6f}, shared condenser {A_cond:.6f}")
print(f" system with shared items: availability {A_sys:.6f}, "
f"{(1 - A_sys) * YEAR:.2f} h a year")
print(f" real gain over one compressor on the same shared items: "
f"{(1 - A_power * A_cond * A) / (1 - A_sys):.1f} times")
print(f" share of system downtime from the shared items: "
f"{100 * (1 - A_power * A_cond) / (1 - A_sys):.1f} %")
P_START = 0.95 # chance that the standby takes the load when called
calls = lam * YEAR
no_cooling = calls * (1.0 - P_START)
print(f" calls on the standby: {calls:.2f} a year; with a start chance of {P_START}: "
f"{no_cooling:.3f} a year find no standby, one in {1 / no_cooling:.1f} years")
C_NO, C_YES = 380000.0, 150000.0 # cost of a failure without and with the standby
print(f" expected failure cost a year: no standby {calls * C_NO:,.0f}, "
f"perfect standby {calls * C_YES:,.0f}, "
f"standby that starts 95 % of the time "
f"{calls * (P_START * C_YES + (1 - P_START) * C_NO):,.0f}")
# ---------- Plot ----------
fig, ax = plt.subplots(2, 1, figsize=(8, 8))
ax[0].vlines(t, 0.0, repair, linewidth=3)
ax[0].set_xlim(0.0, T)
ax[0].set_xlabel("running hours")
ax[0].set_ylabel("repair time (h)")
ax[0].set_title("Compressor failures over five years")
ks = np.arange(1, 41)
lows = np.array([mtbf_interval(k * mtbf, k)[0] for k in ks]) / mtbf
highs = np.array([mtbf_interval(k * mtbf, k)[1] for k in ks]) / mtbf
ax[1].fill_between(ks, lows, highs, alpha=0.3)
ax[1].axhline(1.0, color="gray", linewidth=0.8, linestyle="--")
ax[1].axvline(n, color="black", linewidth=0.8)
ax[1].set_ylim(0.0, 4.0)
ax[1].set_xlabel("number of failures in the record")
ax[1].set_ylabel("90 % interval / estimated MTBF")
ax[1].set_title("How the interval narrows with more failures")
fig.tight_layout()
fig.savefig("availability.png", dpi=120)
print("Saved availability.png")

Expected output

Application 1: one compressor, five years of record
failures at (h): [7759, 8142, 10137, 10749, 10800, 17765, 24818, 25379, 34181]
repair times (h): [7.1, 12.0, 11.1, 2.4, 12.0, 8.2, 7.4, 7.9, 10.7]
hours between failures: [7759, 383, 1995, 612, 51, 6965, 7053, 561, 8802]
9 failures in 42000 h: MTBF 4667 h, 1.80 failures a year
total repair 78.8 h, MTTR 8.76 h, median 8.2 h, longest 12.0 h
availability 0.99813 (99.813 %), unavailability 0.00187
downtime a year: 15.7 h from the availability, 15.8 h from the record
survive to the MTBF: 0.368, a year with no failure: 0.165
chi-square values: 31.41 (20 degrees of freedom), 9.39 (18)
90 % interval for the MTBF: 2674 to 8945 h
as failures a year: 0.94 to 3.14
availability at the ends of the interval: 0.99674 to 0.99902, downtime 8.2 to 27.4 h a year
a record of 2 failures in 1 year: MTBF 4200 h, interval 1334 to 23638 h (ratio 17.7)
a record of 9 failures in 5 years: MTBF 4667 h, interval 2674 to 8945 h (ratio 3.3)
a record of 36 failures in 20 years: MTBF 4667 h, interval 3534 to 6285 h (ratio 1.8)
a year with no failure at all: 90 % sure only that the MTBF is above 3648 h
Application 2: duty and standby compressors
one compressor: unavailability 0.001873, 15.7 h a year
two independent compressors: unavailability 3.507e-06, availability 0.9999965, 1.8 min a year
gain from the standby if independent: 534 times
shared supply 0.999524, shared condenser 0.999286
system with shared items: availability 0.998806, 10.03 h a year
real gain over one compressor on the same shared items: 2.6 times
share of system downtime from the shared items: 99.7 %
calls on the standby: 1.80 a year; with a start chance of 0.95: 0.090 a year find no standby, one in 11.1 years
expected failure cost a year: no standby 684,000, perfect standby 270,000, standby that starts 95 % of the time 290,700
Saved availability.png

Common Mistakes



  • Reading the MTBF as the life of the machine. With a constant failure rate 63 percent of runs end before it, and it is no guide to a replacement age.
  • Dividing calendar hours by failures for a machine that does not run all the time. Use running hours, or the MTBF looks better than it is.
  • Quoting an availability without saying what the down time includes. Inherent and operational availability of one machine can differ by a factor of ten in downtime hours.
  • Reporting an MTBF from two or three failures as a fact. Give the confidence interval, or say the record is too short.
  • Multiplying the unavailabilities of two units that share a supply, a condenser, a control panel or a maintenance error. The shared cause is in series and usually decides the result.
  • Assuming a standby works because it is there. A standby that never runs can be failed for months without anyone knowing.

Summary



  • MTBF is total running hours divided by failures, MTTR is the mean down time, and steady-state availability is . Each must state what was counted.
  • The MTBF is a rate written the other way up, not a life. With a constant rate only 37 percent of runs reach it.
  • The compressor record gave 9 failures in 42,000 hours: an MTBF of 4,667 hours, an MTTR of 8.76 hours, an availability of 0.99813 and about 15.7 hours of downtime a year.
  • Nine failures fix the MTBF only between 2,674 and 8,945 hours at 90 percent confidence. The width depends on the number of failures.
  • Units in series multiply their availabilities. Two independent units in parallel multiply their unavailabilities: 1.8 minutes a year without cooling for the two compressors.
  • With a shared supply and condenser the same pair gives 10.03 hours a year. The shared causes, and whether the standby starts, limit what redundancy can deliver.

Exercises



1. A borehole pump ran 30,000 hours in a record that holds 6 failures. The down times add to 54 hours, counted from stop to restart. Find the MTBF, the MTTR, the availability and the downtime in a year of 8,400 hours.

Answer

MTBF h. MTTR h. . Downtime hours a year. It is an operational availability for unplanned stops.

2. A conveyor needs its motor, its gearbox and its belt. Their availabilities are 0.995, 0.990 and 0.985. Find the availability of the conveyor and its downtime in a year of 8,400 hours.

Answer

. Downtime hours a year.

3. A machine has an MTBF of 3,000 hours. The active repair takes 4 hours on average, and each stop also waits 20 hours on average for a technician to arrive. Find the inherent and the operational availability, and the downtime a year of 8,400 hours for each.

Answer

Inherent: , which is 11.2 hours a year. Operational: , which is 66.7 hours a year. Five sixths of the downtime is waiting, so faster response is worth more than faster repair.

4. A generator has 4 failures in a record of 16,800 running hours that ended at a fixed date. Assume a constant failure rate. Find the MTBF and its 90 percent confidence interval. Use and .

Answer

MTBF h. Lower limit h. Upper limit h. The upper limit is 6.7 times the lower: four failures say little.

5. Two identical pumps are in parallel, and either can do the duty. Each has an availability of 0.98. Find the availability of the pair if they are independent. Then find it if both are fed from one supply with an availability of 0.999, and give the downtime in a year of 8,400 hours for both cases.

Answer

Independent: , which is 3.4 hours a year. With the shared supply: , which is 11.8 hours a year. The supply, which looked far better than either pump, causes most of the downtime.

References



  • P. D. T. O’Connor and A. Kleyner, Practical Reliability Engineering, 5th edition, Wiley, 2012.
  • C. E. Ebeling, An Introduction to Reliability and Maintainability Engineering, 2nd edition, Waveland Press, 2010.
  • J. Moubray, Reliability-centred Maintenance, 2nd edition, Butterworth-Heinemann, 1997.
  • ISO 14224, Petroleum, petrochemical and natural gas industries: Collection and exchange of reliability and maintenance data for equipment (named here as the reference for how failure and repair records are collected).


© 2021-2026 SiliconWit®. All rights reserved.
Watch it build: series, then parallel
Series: all three are needed motor gearbox belt 0.995 0.990 0.985 0.995 × 0.990 × 0.985 = 0.970 250 h down a year: worse than the belt Parallel: one is enough compressor 1 compressor 2 0.99 each each one down 84 h a year 1 − 0.01 × 0.01 = 0.9999 0.84 h down a year, on paper
  1. A conveyor needs its motor, its gearbox and its belt: in series, all three must be up.
  2. The availabilities multiply to 0.970: 250 hours down a year, worse than the worst unit.
  3. Two compressors in parallel, each 0.99: either one can do the whole duty.
  4. Both must be down together: 0.01 × 0.01, so 0.84 hours a year instead of 84, on paper.
Predict first

A data sheet gives an MTBF of 50,000 hours, almost six years. A site puts 100 new units into service and runs them all year, 8,760 hours. With a constant failure rate, about how many fail in the first year?

See it: 100 machines and one MTBF

Still running, no failure yet
By the formula e^(−t/MTBF)
Mean of the 100 lives

Each dot is one machine. All 100 start new at the same moment and each runs until its first failure, at a time drawn from a constant failure rate. The curve counts the machines that still run. Stop at the MTBF: 63 have failed. A few machines run three, four or five times the MTBF, and those long lives pull the mean up to the MTBF while most lives are shorter.

one stop: 10 hours from failure to restart waitingwaiting for the part for a persondiagnosisrestart repair with tools: 40 minutes
See it: what the standby really adds

Gain on paper, nothing shared
Real gain, with the shared items
Share from the shared items

The cold store of Application 2, in a year of 8,400 hours. The shared supply and the shared condenser are in series with the pair, so their hours are lost whatever the compressors do. Set both shared items to zero to see the gain on paper. Set the compressor worse, and the pair still loses little: the shared items decide the result.

one supply compressor 1compressor 2 stoppedstopped one condenser shared: in series

Check yourself

Three questions. Each wrong choice is a mistake people really make, so read the note after you answer.

1. A fan has an MTBF of 2,000 running hours. Each repair takes 6 hours of work, and each stop also waits 30 hours on average for the part. What availability does the owner live with?

2. Two identical pumps are in parallel, and either can do the duty. Each pump is down 84 hours a year, and both take power from one supply that is down 8 hours a year. About how many hours a year is there no pumping?

3. A machine had 3 failures in two years (16,800 running hours). After a change of oil it had 1 failure in the next year (8,400 hours). The manager says the change raised the MTBF from 5,600 to 8,400 hours. What do you say?

Electrical supply shared Compressor 1 (duty) Compressor 2 (standby) Condenser shared Cold room either one holds the load
Two compressors, one supply and one condenser
up down TBF₁ TTR₁ TBF₂ TTR₂ TBF = running time between failures TTR = time to return to service example, not to scale
The record of a repairable machine
waiting for the person diagnosis waiting for the part repair restart and test failure running down time of the stop example: parts drawn equal, not to scale
What one stop is made of