Modules, Strings and Shading

Lesson 3 of 10 26 min read
Found this useful?

A vent pipe throws a shadow the width of a hand across one module, and the whole string gives less every afternoon. Nobody sees it, because the array still works and the meter still turns. On another roof an installer adds three modules to a string to use the space that was left, and on the first cold clear morning the inverter shows a voltage fault, or fails without showing anything. Both problems come from the same fact: modules in a string are in series, so they share one current and their voltages add. This lesson shows how to add modules correctly, how to check a string against the limits of the inverter, and what shade really costs. #SolarPV #Shading #BypassDiodes

Learning Objectives

By the end of this lesson, you will be able to:

  1. Calculate the voltage and current of modules connected in series and in parallel
  2. Check a string against the maximum voltage, the tracking range and the current limit of an inverter at the coldest and the hottest cell
  3. Explain why one weak cell limits a series string, what reverse bias and a hot spot are, and what a bypass diode does
  4. Build the curve of a partly shaded module from the curves of its groups, and find both power peaks
  5. Estimate the power a string loses to one shaded group

Real-World System Problem: Eighteen modules on a workshop roof



The site of this course is a workshop and office near the equator. Its roof carries 18 modules of 550 W, which is 9.9 kWp at standard test conditions (STC: 1000 W/m², cell at 25 °C). A hot roof never meets those conditions, so 9.9 kW is a label and not a promise. The modules are wired as two strings of nine. Each string goes to its own tracker input on a hybrid inverter.

The inverter has limits on each input. The voltage must never pass 600 V, or the input is damaged. The tracker can only find the best working point between 150 V and 500 V. And each input accepts 20 A. The string must stay inside all three in every condition the roof will see, from a cold clear dawn to a hot noon.

The roof also has a vent pipe and a parapet wall, and each puts a shadow on some part of the array at some hour. The owner wants to know two things: could the strings have been longer, and how much does a small shadow take?

93219321Tracker 1InverterTracker 2String A: nine modules in series...String B: nine modules in series...Limits of each input: 600 V, 150 to 500 V, 20 A
The array of the site: two strings of nine

Fundamental Theory: Cells in series and what shade does to them



Series adds voltage, parallel adds current

Two rules cover every array.

In a series connection the same current passes through every module, and the voltages add. Nine modules in series have nine times the voltage of one module and the current of one module.

In a parallel connection every branch sits at the same voltage, and the currents add. Two strings in parallel have the voltage of one string and twice the current.

13 A13 A42 V42 V42 VSeries: one current, the voltages add126V,13AParallel: one voltage, the currents add42V,26A
Series adds voltage. Parallel adds current

For equal modules in series and equal strings in parallel:

The power is the same in both arrangements. A high voltage with a low current needs thinner cable and loses less in it, so designers make strings as long as the inverter allows.

A module is itself a series string. The example module has 144 half cells, which this course treats as 72 cells in series. Each cell gives about 0.69 V at open circuit, and 72 of them give the 49.90 V on the data sheet.

The weakest cell sets the current

A series connection has one current, so if one cell can make less current than the others, the whole chain is limited to about the current of that cell, as a kink limits the flow of a whole hose.

A cell makes current in proportion to its light: under a shadow that passes 20 percent of the light, about 20 percent of the current. In series with 71 cells in full sun, the 71 good cells cannot push their full current through it by normal means.

The same happens in a smaller way without any shadow. Modules of one type are not identical: one has a little less current than the next because of how it was made, or because it is dirtier or older. This is mismatch. In a series string every module works at the current that suits the whole string, not its own best, so the string gives a little less than the sum of the modules measured one at a time.

Mismatch in parallel is of the other kind. Parallel strings share one voltage, so a string with fewer modules, or facing another direction and cooler or hotter, is held at a voltage that is not its best. So strings on one tracker should have the same number of modules of the same type on the same roof face; strings that differ go to separate trackers.

Reverse bias and hot spots

What happens to the shaded cell if the string is made to carry more current than the cell can make?

The good cells are current sources: they raise the voltage across the weak cell in the reverse direction until the current passes. The cell is now reverse biased, its voltage has changed sign, and with a negative voltage and a positive current it is no longer a generator but a load. The power it absorbs becomes heat inside it.

The heat is not spread evenly. Reverse current passes through the weakest small areas of the cell, which become very hot: a hot spot. It can damage the module and, in the worst case, start a fire.

The bypass diode

The protection is a diode connected across a group of cells, pointing so that it does not conduct while the group is generating.

diode 1diode 2diode 3(-)(+)Group 1Group 2Group 324 cells24 cells24 cells
One module: three groups, each with a bypass diode

While all cells are in the sun, each group has about 14 V at the working point, which the diode sees in its blocking direction, so it does nothing.

When one cell of a group is shaded and the string asks for more current than that cell can make, the group voltage falls. At about half a volt negative the diode conducts, the extra current passes around the group like water through a side pipe, the group is held at about V, and the rest of the string continues at full current.

The diode does two things:

  • It limits the loss. The string loses the voltage of one group, and a small diode drop, in place of most of its current.
  • It limits the reverse voltage on the shaded cell. With the diode conducting, the 23 good cells of the group can put at most their own voltage plus the diode drop across the weak cell: about V. Without the diode, the whole string would stand behind it.

That limit is why a module has three diodes and not one: groups of about 24 cells keep the reverse voltage on any one cell at a level a cell is built to survive. A cell can still become hot under that voltage, and a module in the same hard shadow every day ages faster there. The diode reduces the danger; it does not remove it.

The model in this lesson uses an ideal diode with a fixed drop of 0.5 V: it conducts nothing until the group voltage reaches V, and then it holds the group at that voltage. A real bypass diode has a drop that depends on its type and current, and it also becomes warm (at 10 A and 0.5 V it dissipates 5 W inside the junction box). The maker’s data sheet decides.

Steps in the curve and two peaks

To build the curve of a module with unequal groups, use the series rule in the correct direction: the current is common, so for each value of current find the voltage of each group at that current, and add them.

For a group in the sun this is a point on its normal curve. A shaded group is still a generator, on its own lower curve, while the current is below what it can make; above that, the diode conducts and the group voltage is V.

The result is a curve with a step.

I (A)13.9two groups work,diode conducts2.8all three groups work0V032 V48.8 V
Curve of a module with one group at 20 % light

Power is voltage times current, so each flat part of the curve has its own knee and power peak: one at high current and low voltage, with the shaded group bypassed, and one at low current and high voltage, with all three groups at the shaded group’s current. The better is the global peak; the other is a local peak, and a tracker that climbs to it stays there.

String voltage at the coldest and hottest cell

The voltage of a cell falls as it warms. For the example module the data sheet gives percent of per degree. At a cell temperature :

A string therefore has its highest voltage when it is coldest and its lowest when it is hottest, and the two ends are checked against different limits.

Two voltage checks for a string of N modules

The first protects the inverter. The second keeps the maximum power point inside the range where the tracker can reach it.

The cold check uses the open-circuit voltage because that is what the string shows before the inverter starts to draw current: a clear dawn, cold modules, light already on them. It uses full irradiance although dawn light is weak, because the voltage falls only a little in weak light (the model gives 46.56 V at 200 W/m² against 49.90 V at 1000) and the cautious choice costs little.

The cold temperature is the lowest cell temperature the site can have in daylight, taken from weather records. The hot temperature is the cell on a still, sunny afternoon, far above the air.

The current check is simpler. Current rises with light and a little with temperature. The short-circuit current of all strings on one input must stay below the input limit, with a margin, because the edge of a bright cloud can lift the irradiance above 1000 W/m² for a short time. The size of the margin is set by the local wiring code and the maker of the inverter.

Application 1: The string of nine against the inverter limits



Step 1: The cold check against 600 V

Click to reveal the calculation
  1. Module at 10 °C by the data sheet coefficient. The cell is 15 degrees below STC.

    The model gives the same value, because the model is built on this coefficient. ✅

  2. String of 9.

    This is below 600 V. ✅

  3. Margin. V, which is 22.1 percent of the limit. ✅

Step 2: The tracking range and the current

Click to reveal the calculation
  1. Hot afternoon. V. The maximum power point is above the 150 V lower limit of the tracker. ✅

  2. Cold morning. V. The maximum power point is below the 500 V upper limit. ✅

  3. Current of one string. The largest short-circuit current in the table is 14.14 A at 60 °C. It is below 20 A, with 5.86 A to spare for irradiance above 1000 W/m². ✅

  4. Two strings on one input. In parallel the currents add: A. This is above 20 A. The site therefore has one string on each tracker, and not two strings on one. ✅

Step 3: The longest and shortest string

Click to reveal the calculation
  1. Longest string by the 600 V limit. , so 11 modules. Their cold open-circuit voltage is V. ✅

  2. Tracking range for 11. Cold: V, still below 500 V. Hot: V. Eleven modules pass every check, with only 28.9 V of margin to the damage limit. ✅

  3. Twelve modules. V. This is 23.1 V above the maximum input voltage. A string of 12 is not allowed, although its working voltage on a hot day (443.5 V) looks comfortable. ✅

  4. Shortest string by the tracking range. , so at least 5 modules ( V). With 4 modules the hot maximum power point is at 147.8 V, below the range, and the tracker would hold the string at a voltage above its best point. ✅

Step 4: Check with a second method

Click to reveal the check
  1. Scale the limit, not the module. Divide the inverter limit by the cold factor: V is the largest STC open-circuit voltage a string may have. modules, the same as Step 3. ✅

  2. The Python script below finds the same table values from the model, the same counts of 11 and 5, and 623.1 V for a string of 12. ✅

Application 2: One shaded group in one module



Step 1: One group, and three groups in series

Click to reveal the calculation
  1. One group in full light. The model gives A and V, which is . ✅

  2. One group at 200 W/m². A and V. The current fell to one fifth. The voltage fell by only 7 percent. ✅

  3. Three groups in full light in series. For each current, add three equal group voltages. The maximum is 549.9 W at 41.89 V and 13.13 A. The whole-module model gives 549.9 W, so the scaling to a group is correct. ✅

Step 2: The shaded module and its two peaks

Click to reveal the calculation
  1. Below 2.78 A. All three groups generate. At open circuit the module voltage is V. ✅

  2. Above 2.78 A. The shaded group cannot make the current. Its diode conducts and holds it at V. Just above the step the module voltage is about 32.2 V: two good groups near their open-circuit voltage, less the diode drop. ✅

  3. Peak at high voltage. All three groups work at the current of the shaded one. The model gives 119.8 W at 45.20 V and 2.65 A. ✅

  4. Peak at low voltage. Two groups work at full current and the third is bypassed. The model gives 360.0 W at 27.45 V and 13.12 A. This is the global peak. ✅

  5. Loss for the module. At the global peak: W, which is 34.5 percent. If a tracker held this module at the other peak, the loss would be 430.1 W, which is 78.2 percent. ✅

  6. The diode. At the global peak the shaded group still makes 2.78 A, so the diode carries A and dissipates W. ✅

Step 3: What the string loses

Click to reveal the calculation
  1. String in full light. Nine modules give W at 377.0 V and 13.13 A. ✅

  2. String with the shaded group. Add the voltage of eight good modules and the shaded module at each current. The maximum is 4,759.2 W at 362.5 V and 13.13 A. ✅

  3. Loss. W, which is 3.84 percent of the string. The eight good modules lose nothing: they still work at their own best current. ✅

  4. Only one peak. At 2.65 A, where the single module had its second peak, the string gives 1,160.6 W at 438.0 V. In the string curve this point is a small shoulder and not a peak, because the eight good modules gain more from a rising current than the shaded module loses. ✅

  5. Compare with the light. The shaded group is 1 of 27 groups in the string and lost 80 percent of its light: percent of the light on the string. The power loss of 3.84 percent is larger, because the group gives nothing at all once it is bypassed, and the diode takes a little more. ✅

Step 4: The same shadow across all three groups

Click to reveal the calculation
  1. Module. If the shadow lies along the module so that every group has cells at 20 percent light, no group can carry the full current. The whole module is at 200 W/m²: 102.1 W at 39.98 V and 2.55 A. ✅

  2. String. The string now has two peaks: 1,146.6 W at 426.9 V and 2.69 A (all modules at the current of the shaded one), and 4,379.5 W at 333.7 V and 13.13 A (the shaded module bypassed by all three diodes). ✅

  3. Loss. At the global peak the string loses W, which is 11.51 percent: one whole module and three diode drops. ✅

Step 5: Check by hand

Click to reveal the check
  1. Bypassed group by hand. Two groups at their maximum power voltage give V. Less the diode drop, 27.43 V. At 13.1 A that is 359.4 W. The model gave 360.0 W. ✅

  2. Bypassed module by hand. Eight modules at 550 W less three diode drops at 13.1 A: W. The model gave 4,379.5 W. ✅

  3. Limiting case. With all three groups at 1000 W/m² the script returns the unshaded module, 549.9 W, and with all at 200 W/m² it returns 102.1 W, the value of the whole-module model at that light. ✅

Verify It in Python



The script holds the module model of the course, checks the string against the inverter limits, then builds the curves of the shaded module and the string. It saves one plot of the module curve with and without the shaded group.

shading.py
"""Strings, shading and bypass diodes for the example 550 W module."""
import numpy as np
from scipy.optimize import brentq, minimize_scalar
import matplotlib.pyplot as plt
K_B, Q = 1.380649e-23, 1.602176634e-19
def module_current(v, g=1000.0, t_cell=25.0, ns=72, n=1.1, rs=0.14, rsh=400.0,
isc_stc=13.90, voc_stc=49.90, a_isc=0.0005, b_voc=-0.0027):
"""Current (A) of the example 550 W module at voltage v (V), irradiance g (W/m2)
and cell temperature t_cell (deg C). Single-diode model."""
tk = t_cell + 273.15
vt = ns * n * K_B * tk / Q
iph = isc_stc * (g / 1000.0) * (1 + a_isc * (t_cell - 25.0))
voc_t = voc_stc * (1 + b_voc * (t_cell - 25.0))
i0 = (isc_stc * (1 + a_isc * (t_cell - 25.0)) - voc_t / rsh) / (np.exp(voc_t / vt) - 1)
f = lambda i: iph - i0 * (np.exp((v + i * rs) / vt) - 1) - (v + i * rs) / rsh - i
return brentq(f, -200.0, iph + 1.0)
def module_points(g, t_cell):
"""I_sc, V_oc, V_mp, I_mp and P_mp of the whole module."""
isc = module_current(0.0, g, t_cell)
voc = brentq(lambda v: module_current(v, g, t_cell), 1.0, 70.0)
r = minimize_scalar(lambda v: -v * module_current(v, g, t_cell),
bounds=(0.5 * voc, voc), method="bounded",
options={"xatol": 1e-6})
return isc, voc, r.x, -r.fun / r.x, -r.fun
# ---------- Application 1: how many modules in a string ----------
V_MAX, V_LOW, V_HIGH, I_TRACKER = 600.0, 150.0, 500.0, 20.0
T_COLD, T_HOT = 10.0, 60.0
isc_c, voc_c, vmp_c, imp_c, pmp_c = module_points(1000.0, T_COLD)
isc_h, voc_h, vmp_h, imp_h, pmp_h = module_points(1000.0, T_HOT)
print("Application 1: the string of 9 against the inverter limits")
print(f" module, cell at {T_COLD:.0f} C: V_oc {voc_c:.2f} V, V_mp {vmp_c:.2f} V, I_sc {isc_c:.2f} A")
print(f" module, cell at {T_HOT:.0f} C: V_oc {voc_h:.2f} V, V_mp {vmp_h:.2f} V, I_sc {isc_h:.2f} A")
print(f" V_oc at {T_COLD:.0f} C from the data sheet coefficient: "
f"{49.90 * (1 - 0.0027 * (T_COLD - 25.0)):.2f} V")
for k in (9, 11, 12):
print(f" string of {k:2d}: V_oc cold {k * voc_c:.1f} V, V_mp cold {k * vmp_c:.1f} V, "
f"V_mp hot {k * vmp_h:.1f} V")
print(f" most modules below {V_MAX:.0f} V: {int(V_MAX // voc_c)}; "
f"fewest above {V_LOW:.0f} V when hot: {int(np.ceil(V_LOW / vmp_h))}")
print(f" margin of the string of 9 to {V_MAX:.0f} V: {V_MAX - 9 * voc_c:.1f} V "
f"({100 * (V_MAX - 9 * voc_c) / V_MAX:.1f} %)")
print(f" one string: I_sc hot {isc_h:.2f} A; two in parallel {2 * isc_h:.2f} A; "
f"tracker limit {I_TRACKER:.0f} A")
# ---------- Application 2: one shaded group ----------
V_DIODE = 0.5 # ideal bypass diode: conducts with a fixed 0.5 V drop
def group_current(v, g):
"""One bypass group at 25 C: 24 cells, one third of the module."""
return module_current(v, g, 25.0, ns=24, rs=0.14 / 3, rsh=400.0 / 3,
voc_stc=49.90 / 3)
def group_voltage(i, g):
"""Voltage of one group, with its bypass diode, when the current i passes."""
if group_current(-V_DIODE, g) <= i:
return -V_DIODE # the diode carries the difference
return brentq(lambda v: group_current(v, g) - i, -V_DIODE, 18.0)
def curve(groups, i_grid):
"""Voltage of groups in series, each given as its irradiance, at each current."""
return np.array([sum(group_voltage(i, g) for g in groups) for i in i_grid])
def peaks(v, i):
"""Local maxima of power along a curve given at rising current."""
p = v * i
k = [j for j in range(1, len(p) - 1) if p[j] > p[j - 1] and p[j] >= p[j + 1]]
return [(v[j], i[j], p[j]) for j in k]
i_grid = np.arange(0.0, 13.9, 0.002)
print("Application 2: one group of one module shaded to 20 % light")
gi = group_current(0.0, 1000.0)
gv = brentq(lambda v: group_current(v, 1000.0), 1.0, 20.0)
print(f" one group in full light: I_sc {gi:.2f} A, V_oc {gv:.3f} V")
si = group_current(0.0, 200.0)
sv = brentq(lambda v: group_current(v, 200.0), 1.0, 20.0)
print(f" one group at 200 W/m2: I_sc {si:.2f} A, V_oc {sv:.3f} V")
v_full = curve([1000.0] * 3, i_grid)
(v0, i0, p0), = peaks(v_full, i_grid)
print(f" three groups in full light: {p0:.1f} W at {v0:.2f} V, {i0:.2f} A "
f"(whole module model: {module_points(1000.0, 25.0)[4]:.1f} W)")
v_shade = curve([1000.0, 1000.0, 200.0], i_grid)
pk = peaks(v_shade, i_grid)
for name, (v, i, p) in zip(("peak at high voltage", "peak at low voltage "), pk):
print(f" shaded module, {name}: {p:.1f} W at {v:.2f} V, {i:.2f} A")
p_hi, p_lo = pk[0][2], pk[1][2]
print(f" module loss at the better peak: {p0 - p_lo:.1f} W ({100 * (1 - p_lo / p0):.1f} %); "
f"at the other peak: {p0 - p_hi:.1f} W ({100 * (1 - p_hi / p0):.1f} %)")
i_lo = pk[1][1]
print(f" at the better peak the diode carries {i_lo - group_current(-V_DIODE, 200.0):.2f} A "
f"and dissipates {V_DIODE * (i_lo - group_current(-V_DIODE, 200.0)):.1f} W")
v_string_ok = 9 * v_full
v_string = 8 * v_full + v_shade
(vs0, is0, ps0), = peaks(v_string_ok, i_grid)
print(f" string of 9 in full light: {ps0:.1f} W at {vs0:.1f} V, {is0:.2f} A")
spk = peaks(v_string, i_grid)
print(f" string with the shaded group: {len(spk)} peak")
for v, i, p in spk:
print(f" string peak: {p:.1f} W at {v:.1f} V, {i:.2f} A")
k = int(np.argmin(np.abs(i_grid - pk[0][1])))
print(f" at {i_grid[k]:.2f} A (the high voltage peak of the module) the string gives "
f"{v_string[k] * i_grid[k]:.1f} W at {v_string[k]:.1f} V")
ps = max(p for _, _, p in spk)
print(f" string loss at the better peak: {ps0 - ps:.1f} W ({100 * (1 - ps / ps0):.2f} %)")
print(f" light lost by the string: {100 * 0.8 / 27:.2f} %")
v_edge = curve([200.0] * 3, i_grid)
(ve, ie, pe), = peaks(v_edge, i_grid)
print(f" the same shade across all three groups: module {pe:.1f} W at {ve:.2f} V, {ie:.2f} A")
epk = peaks(8 * v_full + v_edge, i_grid)
for v, i, p in epk:
print(f" string peak: {p:.1f} W at {v:.1f} V, {i:.2f} A")
pe_s = max(p for _, _, p in epk)
print(f" string loss: {ps0 - pe_s:.1f} W ({100 * (1 - pe_s / ps0):.2f} %)")
# ---------- Plot ----------
fig, ax = plt.subplots(2, 1, figsize=(8, 8), sharex=True)
ax[0].plot(v_full, i_grid, label="full light")
ax[0].plot(v_shade, i_grid, label="one group at 20 % light")
ax[0].set_ylabel("current (A)")
ax[0].set_title("One module: the bypass diode puts a step in the curve")
ax[0].legend()
ax[1].plot(v_full, v_full * i_grid, label="full light")
ax[1].plot(v_shade, v_shade * i_grid, label="one group at 20 % light")
for v, i, p in pk:
ax[1].plot(v, p, "ko")
ax[1].set_xlim(0.0, 52.0)
ax[1].set_xlabel("module voltage (V)")
ax[1].set_ylabel("power (W)")
ax[1].legend()
fig.tight_layout()
fig.savefig("shading.png", dpi=120)
print("Saved shading.png")

Expected output

Application 1: the string of 9 against the inverter limits
module, cell at 10 C: V_oc 51.92 V, V_mp 44.03 V, I_sc 13.79 A
module, cell at 60 C: V_oc 45.18 V, V_mp 36.96 V, I_sc 14.14 A
V_oc at 10 C from the data sheet coefficient: 51.92 V
string of 9: V_oc cold 467.3 V, V_mp cold 396.3 V, V_mp hot 332.6 V
string of 11: V_oc cold 571.1 V, V_mp cold 484.3 V, V_mp hot 406.5 V
string of 12: V_oc cold 623.1 V, V_mp cold 528.4 V, V_mp hot 443.5 V
most modules below 600 V: 11; fewest above 150 V when hot: 5
margin of the string of 9 to 600 V: 132.7 V (22.1 %)
one string: I_sc hot 14.14 A; two in parallel 28.28 A; tracker limit 20 A
Application 2: one group of one module shaded to 20 % light
one group in full light: I_sc 13.90 A, V_oc 16.633 V
one group at 200 W/m2: I_sc 2.78 A, V_oc 15.519 V
three groups in full light: 549.9 W at 41.89 V, 13.13 A (whole module model: 549.9 W)
shaded module, peak at high voltage: 119.8 W at 45.20 V, 2.65 A
shaded module, peak at low voltage : 360.0 W at 27.45 V, 13.12 A
module loss at the better peak: 189.9 W (34.5 %); at the other peak: 430.1 W (78.2 %)
at the better peak the diode carries 10.34 A and dissipates 5.2 W
string of 9 in full light: 4949.1 W at 377.0 V, 13.13 A
string with the shaded group: 1 peak
string peak: 4759.2 W at 362.5 V, 13.13 A
at 2.65 A (the high voltage peak of the module) the string gives 1160.6 W at 438.0 V
string loss at the better peak: 189.9 W (3.84 %)
light lost by the string: 2.96 %
the same shade across all three groups: module 102.1 W at 39.98 V, 2.55 A
string peak: 1146.6 W at 426.9 V, 2.69 A
string peak: 4379.5 W at 333.7 V, 13.13 A
string loss: 569.6 W (11.51 %)
Saved shading.png

Common Mistakes



  • Checking the string voltage at STC. The highest voltage comes on the coldest bright morning, and it is the open-circuit voltage, not the working voltage.
  • Using the yearly mean or the lowest night temperature without thought. The cold check needs the lowest cell temperature that can occur with light on the modules, from weather records for the site.
  • Putting two strings on one tracker input without adding their currents, or putting strings of different length or direction in parallel.
  • Estimating a shading loss from the shaded area. One shaded cell can remove a whole group, and a shadow across all three groups can remove the module.
  • Believing that bypass diodes make shade harmless. They limit the loss and the reverse voltage. The bypassed group still gives nothing, and a cell in daily hard shade still runs hot.

Summary



  • In series the current is common and the voltages add. In parallel the voltage is common and the currents add. A module is 72 cells in series, and a string is modules in series.
  • The weakest cell limits the current of a series chain. Forced beyond its current, a cell goes into reverse bias and heats.
  • A bypass diode across each group of 24 cells lets the string current pass around a weak group. It costs the voltage of that group and about 0.5 V, and it puts a step in the curve and a second peak in the power.
  • The string of nine has a cold open-circuit voltage of 467.3 V against a 600 V limit and a hot working voltage of 332.6 V inside the 150 to 500 V tracking range. Eleven is the longest string allowed. Twelve would reach 623.1 V.
  • One group at 20 percent light costs its module 189.9 W of 549.9 W and the string 3.84 percent. The same shadow across all three groups costs the string 11.5 percent.

Exercises



1. Six example modules are connected in series, and two such strings are connected in parallel. Using the STC values ( V, A), find the open-circuit voltage and the short-circuit current of the array.

Answer

Series: V. Parallel: A. The array has 299.4 V and 27.8 A at STC.

2. At another site the coldest cell in daylight is 0 °C. Use %/°C to find of the example module at 0 °C, and the longest string for an inverter input with a 600 V limit and for one with a 1000 V limit.

Answer

V. For 600 V: , so 11 modules (585.9 V). For 1000 V: , so 18 modules (958.8 V).

3. Two modules are in series. Tested alone, the first has its maximum power at 41.9 V and 13.1 A, and the second at 41.9 V and 12.4 A. Estimate the power of the pair by assuming both work at 12.4 A and 41.9 V, and the loss against the sum of the two tested alone.

Answer

Alone: W. In series: W. The loss is 29.3 W, about 2.7 percent. The true loss is a little smaller, because the voltage of the stronger module rises slightly when it works below its best current.

4. One cell in a group of 24 is fully covered by a leaf. The bypass diode of the group conducts with a drop of 0.5 V, and each of the 23 other cells is near its open-circuit voltage of 0.69 V. Find the largest reverse voltage across the covered cell. If the cell passes 2.0 A at 15 V in reverse, how much heat is produced in it?

Answer

Reverse voltage: V at most. Heat: W in one cell. A full module of 72 cells spreads its waste heat over all of them, so 30 W in one cell is a strong local source.

5. In the string of nine, two different modules each have one group shaded to 20 percent light. Use the results of Application 2 to estimate the string power and the loss in percent.

Answer

Each shaded module gives 360.0 W at the string current, so the string gives W. The loss is 379.8 W, which is 7.67 percent. The model confirms 4,569.4 W at 348.1 V.

References



  • G. M. Masters, Renewable and Efficient Electric Power Systems, 2nd edition, Wiley, 2013.
  • R. A. Messenger and A. Abtahi, Photovoltaic Systems Engineering, 4th edition, CRC Press, 2017.
  • J. A. Duffie and W. A. Beckman, Solar Engineering of Thermal Processes, 4th edition, Wiley, 2013.
  • IEC 61215, Terrestrial photovoltaic (PV) modules: Design qualification and type approval (named here as the standard under which modules are tested, including a hot-spot test).


© 2021-2026 SiliconWit®. All rights reserved.
Predict first

A module has three equal groups of cells in series, each with a bypass diode. A shadow takes 80 percent of the light from the cells of one group. The other two groups are in full sun. How much of its power does the module lose, at best?

See it: shade one group and watch the curve step

Global peak
Other peaks
Loss against no shade
Working point
Diodes that conduct there
Open-circuit voltage

The figure is the model of this lesson: the example 550 W module as three groups of 24 cells in series, each group with an ideal bypass diode that drops 0.5 V, all cells at 25 °C. Full light is 1,000 W/m², so 20 % is 200 W/m². At the start one group has 20 % of the light, as in the second application. The working voltage is what the electronics hold the module at. It starts on the global peak: move it, or go to the next peak, and see which diodes conduct and what each group does. The faint dashed curve is the module with no shade. Try the same shade on one group and then on all three, and compare the power. A real diode has a drop that depends on its type and its current, and this model does not give the temperature of a shaded cell. The maker's data sheet decides.

Check yourself

Three questions. Each wrong choice is a mistake people really make, so read the note after you answer.

1. A shadow of the same depth, 20 percent light, can lie on one group of a module or across all three groups. Which case leaves the module more power, taken alone?

2. One group has 20 percent of the light and the module works at its global peak, 27.45 V and 13.12 A. How much current passes through the bypass diode of the shaded group?

3. The shadow on the one group becomes thin: the group now has 70 percent of the light. At the global peak of the module, does the bypass diode of that group conduct?

no bypass: the kink limits the whole hosebypass diode: the flow goes round the kink A shadow on one cell acts like a kink in a hose.
full currentfull currentdiode offdiode off group held at −0.5 Vdiode conducts The string loses one group's voltage, not its current.
Watch it build: a string of nine against the inverter limits
One module: Voc falls as it warms 10 °C 51.92 25 °C 49.90 60 °C 45.18 volts at open circuit, from thedata sheet coefficient −0.27 % per °C × 9 in series: 9 × the module voltage tracking range 0150500600 V cold Voc 467.3 132.7 V under the limit Vmp 332.6 to 396.3 hot to cold: in range 1 string 14.14 A 2 strings 28.28 A 20 A input
  1. One module: 51.92 V open circuit at 10 °C, 49.90 V at 25 °C, 45.18 V at 60 °C.
  2. Nine in series give nine times the voltage. The input has a 600 V limit and a 150 to 500 V tracking range.
  3. Cold dawn, no current yet: 9 × 51.92 = 467.3 V, 132.7 V under the 600 V limit.
  4. Working point from the hot to the cold cell: 332.6 to 396.3 V, inside the tracking range.
  5. One string gives at most 14.14 A, under 20 A. Two strings on one input, 28.28 A, would not fit.
String A: nine modules in series 1 2 3 4 5 6 7 8 9 − + Tracker 1 MPPT input String B: nine modules in series 1 2 3 4 5 6 7 8 9 − + Tracker 2 MPPT input Hybrid inverter Limits of each input: 600 V at most, tracking 150 to 500 V, 20 A
Two strings, one tracker each
Series: one current, the voltages add 42 V 42 V 42 V 13 A through every module 126 V, 13 A Parallel: one voltage, the currents add 13 A 13 A 42 V, 26 A
Series adds voltage. Parallel adds current
− + Group 1 24 cells diode 1 Group 2 24 cells diode 2 Group 3 24 cells diode 3 In full sun each group gives about 14 V, which the diode blocks.
One module: three groups, each with a bypass diode