The Solar Cell and Its I-V Curve

Lesson 2 of 10 26 min read
Found this useful?

A technician connects a 550 W module to a load on a bright day, measures the voltage and the current, multiplies them, and gets 190 W. The module is not faulty. An owner reads the inverter at noon, sees six kilowatts from an array sold as ten, and calls the installer to complain. The array is not faulty either. A solar module has no single output: it gives a different current at every voltage, and the whole curve moves with the light and with the heat of the cells. This lesson shows how to read that curve and how to calculate where a module really works. #SolarCell #IVCurve #MaximumPowerPoint

Learning Objectives

By the end of this lesson, you will be able to:

  1. Explain a solar cell as a current source with a diode, and write the single-diode equation with the meaning of each term
  2. Read an I-V curve and a P-V curve, and find the short-circuit current, the open-circuit voltage, the maximum power point and the fill factor
  3. Predict how irradiance and cell temperature move the curve
  4. Calculate the cell temperature on a roof and the power of a module there from the data sheet coefficient
  5. Describe what series resistance and shunt resistance do to the curve and to the power

Real-World System Problem: A module on a hot roof



The site of this course has 18 modules of 550 W on a workshop roof near the equator: 9.9 kWp of nameplate power. The label on the back of each module gives five numbers at standard test conditions (STC): open-circuit voltage 49.90 V, short-circuit current 13.90 A, voltage at maximum power 41.9 V, current at maximum power 13.1 A, and power 550 W. These values are an example typical of this class of module. For real equipment, the maker’s data sheet decides.

STC means an irradiance of 1,000 W/m², a cell temperature of 25 °C and the air mass 1.5 spectrum. The test is made with a flash of light that is too short to warm the cells. On the roof at noon the conditions are different in both ways. The light is below 1,000 W/m² on most days, and the cells are 20 to 30 °C hotter than the air, because most of the light that a module absorbs becomes heat.

So the owner’s question has a clear form. What does this module give at 800 W/m² with the air at 30 °C? To answer it we need the curve of the module, and the rules for how light and heat move it.

cells at 55 °Clight 800 W/m²(test: 1000 W/m²)(test: 25 °C)outside air at 30 °Croof sheetlabel: 550 Won the roof: about 394 W
A module on the roof at noon against the test conditions

Fundamental Theory: One curve for every condition



A current source with a diode

A solar cell is a thin slice of silicon with a junction inside it, the same kind of junction as in a diode. Light frees charge carriers, and the junction pushes them in one direction: a current proportional to the light, twice the irradiance giving twice the current. This is the photocurrent, .

With the terminals joined by a wire, almost all of the photocurrent flows through the wire: the short-circuit current, , at zero voltage and so zero power.

With the terminals open, the current has nowhere to go outside the cell. The junction voltage rises until the junction, acting as a diode, conducts the whole photocurrent back inside the cell. That voltage is the open-circuit voltage, , about 0.7 V for a silicon cell, at zero current and again zero power.

Between the two ends the cell delivers power. Picture a source of constant current with a diode across it, like a pump with a relief valve: the diode takes almost nothing at low voltage and more and more of the current as the voltage approaches .

Two resistances complete the picture. The series resistance stands for the metal fingers, the ribbons and the silicon that the current must cross. The shunt resistance stands for small leakage paths across the junction. A good cell has a small and a large .

RsRsh○ +IIphDV○ -Iph: current made by the lightD:the junction, acting as a diode
The single-diode model of a cell

The single-diode equation

The current at the terminals is the photocurrent minus the current in the diode minus the current in the shunt resistance. For a module of cells in series:

The single-diode equation of a module

and are the current and the voltage at the terminals. is the saturation current of the diode, a very small current that rises steeply with temperature. is the ideality factor of the diode, a number a little above 1. is the thermal voltage, with the Boltzmann constant, the charge of the electron and the cell temperature in kelvin. At 25 °C it is 25.69 mV.

The term is the voltage inside the module, at the junctions. It is higher than the terminal voltage because the current loses on its way out.

The example module has 144 half cells. Electrically they form two halves in parallel, each with 72 cells in series, and the model treats the module as 72 cells in series. The course model uses , and for the whole module. With these values V at 25 °C and A.

The current is on both sides of the equation, so it cannot be solved with a simple rearrangement. A computer finds the current for each voltage by a root search, and the course function module_current() does exactly that.

The I-V curve and the P-V curve

Solving the equation for every voltage from zero to gives the I-V curve. It has a typical shape: almost flat from short circuit to about four fifths of , then a fall to zero that becomes steeper and steeper.

I (A)maximum power point13.9●41.9V,13.1AIsccurrent stays nearIsc, then falls fastnear open circuit0V041.949.9=Voc
The I-V curve of the example module at STC

Power is voltage multiplied by current. On the flat part the power rises in proportion to the voltage; near the current collapses, and the power with it. Between them is one point where the product is largest: the maximum power point, with voltage , current and power . The plot of power against voltage, the P-V curve, is a hill with this point at its top.

The module does not choose its own point; the thing connected to it does. A resistor of 1 Ω on the example module at STC settles at 13.86 V and 13.86 A, which is 192 W. A resistor of 10 Ω settles at 48.34 V and 4.83 A, which is 234 W. Only a resistor of 3.19 Ω, equal to , takes the full 550 W. This is the answer to the technician at the start of the lesson: the module was able to give 550 W, and the load asked for the wrong voltage.

Fill factor

The largest rectangle that could be imagined on the I-V plot has the sides and . No module reaches it, because no module gives its full current at its full voltage. The fill factor says how close the real maximum comes:

It is a number without units, and for modern silicon modules it is commonly between about 0.75 and 0.83. The fill factor measures how square the curve is. A sharp knee gives a high value. A curve that slopes on the flat part or leans at the voltage end gives a low one. Because it needs only the four label values, it is a quick first check of any data sheet or of any measured curve.

What light does: the current moves

The photocurrent is proportional to the irradiance : at 200 W/m² the short-circuit current of the example module is 2.78 A, one fifth of its value at 1,000 W/m², and the flat part of the curve moves down as a whole.

The voltage changes much less, because at open circuit the diode carries the photocurrent and a diode’s voltage changes with the logarithm of its current. Reducing the light by a factor changes the open-circuit voltage by about

For one fifth of the light this is V. The full model gives 46.56 V at 200 W/m² against 49.90 V at 1,000 W/m², a fall of 6.7 percent for a fall of 80 percent in light.

So power follows the light almost, but not exactly, in proportion: at 200 W/m² and 25 °C the model gives 102.1 W, 18.6 percent of the STC power from 20 percent of the light. The small extra loss comes from the lower voltage and from the shunt resistance, which takes a larger share of a small current.

What heat does: the voltage moves

Temperature acts on the other axis. In a hotter cell the saturation current rises steeply, the diode conducts at a lower voltage, and falls, while the photocurrent rises very slightly: a net loss of power.

Data sheets give three temperature coefficients, each a percentage of the STC value for each degree of cell temperature above 25 °C. For the example module:

QuantitySymbolCoefficient
Short-circuit current % per °C
Open-circuit voltage % per °C
Maximum power % per °C

At a cell temperature of 60 °C, 35 °C above STC, the model gives a short-circuit current of 14.14 A (1.7 percent higher), an open-circuit voltage of 45.18 V (9.5 percent lower) and a maximum power of 487.8 W (11.3 percent lower). At a cold 10 °C the power is 576.2 W, above the nameplate: a cold bright morning is the best condition a module ever meets.

II1000 W/m²500 W/m²60 °C25 °CVVlight: the curve movesheat: the curve movesdowntotheleft
Less light lowers the current, more heat lowers the voltage

The data sheet coefficients lead to a rule that needs no model at all.

Power of a module from its data sheet

is the nameplate power, the plane-of-array irradiance in W/m², the power coefficient as a fraction per °C (here ) and the cell temperature in °C.

The rule treats power as proportional to light. It is a good estimate in strong light and a little optimistic in weak light, as the numbers above showed.

Cell temperature and NOCT

The rule needs the temperature of the cells, not of the air. A module in the sun is warmer than the air around it, and the difference grows with the irradiance. Data sheets describe this with one number, the nominal operating cell temperature (NOCT). It is the cell temperature that the module reaches with an irradiance of 800 W/m², air at 20 °C, a light wind of 1 m/s and free air behind the module. For the example module the NOCT is 45 °C, so the cells are 25 °C above the air under those conditions.

Taking the rise above the air as proportional to the irradiance gives the usual estimate:

With air at 30 °C and 800 W/m² the cells are at °C. With the same air and 1,000 W/m² they are at 61 °C.

This estimate has clear limits. It assumes the wind and the mounting of the NOCT test. Modules fixed close to a metal roof, with little air behind them, run hotter. A strong wind cools them. A sensor on the back of a module gives the real value, and it is the better source when one is fitted.

Series and shunt resistance

The two resistances change the shape of the curve in two different places.

Series resistance acts where the current is large. It lowers the terminal voltage by , so the knee of the curve leans towards lower voltage. does not change, because no current flows there, and hardly changes. Doubling of the example module from 0.14 to 0.28 Ω lowers the maximum power from 549.9 to 525.9 W and the fill factor from 0.793 to 0.759.

Shunt resistance acts where the voltage is large and the current available is small. It lets a current of leak past the load, so the flat part of the curve gets a downward slope. Cutting from 400 to 40 Ω lowers the maximum power to 512.6 W and the fill factor to 0.742. Its effect is strongest in weak light, when the leakage is a larger share of a small photocurrent.

Case (STC) (W)
Ideal: , very large578.60.834
Example module: , 549.90.793
doubled to 0.28 Ω525.90.759
cut to 40 Ω512.60.742

The resistances of a healthy module cost about 5 percent of what the ideal junction could give. They also matter for faults. A corroded connector or a cracked ribbon adds series resistance. A damaged cell or a leakage path lowers the shunt resistance. A measured curve whose fill factor has fallen, with and still near their label values, points to one of the two, and the place where the curve has changed says which.

Application 1: The example module at standard test conditions



Step 1: Points of the curve

Click to reveal the calculation
  1. Run the model. The function gives the current at each voltage, and the power is the product.

    (V) (A) (W)
    013.900
    1013.87138.7
    2013.85276.9
    3013.82414.5
    3513.78482.4
    3813.70520.5
    4013.53541.0
    4213.09549.9
    4412.05530.1
    469.80451.0
    485.74275.5
    49.90.000

    ✅

  2. Read the flat part. From 0 to 35 V the current falls only from 13.90 to 13.78 A, a slope of 0.12 A in 35 V. Most of it is the shunt path: A. ✅

  3. Read the knee. From 42 to 48 V the current falls from 13.09 to 5.74 A. Six volts remove more than half of the current. A load that pulls the module only a few volts above the maximum power point loses a large part of the power. ✅

Step 2: Maximum power point, fill factor and efficiency

Click to reveal the calculation
  1. Maximum power point. A search along the curve gives V, A and

    The top of the hill is flat: at 40 V the power is still 541.0 W, only 1.6 percent below the maximum. ✅

  2. Fill factor from the model.

    ✅

  3. Ratios at the point. and . The module gives up 16 percent of its voltage and 5.5 percent of its current to reach its best power. ✅

  4. Efficiency. At STC the light on the module is W.

    The module converts 21.3 percent of the light to electricity. The other 79 percent is reflected or becomes heat, which is why the cells run hot. ✅

Step 3: Check against the label and in the equation

Click to reveal the check
  1. The label. The label values give W and . The label rounds the voltage and the current to three figures, so their product is 1 W below the stated 550 W. The model agrees with the label to within that rounding. ✅

  2. The open-circuit voltage. With the shunt current ignored, V. ✅

  3. The maximum power point in the equation. At the terminals V and A. The junction voltage is V. The diode takes A and the shunt takes A. The terminal current is A, as the search found. ✅

  4. The load. A resistor of on the curve settles at 41.88 V and 549.9 W. A resistor of 1 Ω gives 192.1 W and one of 10 Ω gives 233.7 W. ✅

Application 2: The hot roof and the noon question



Step 1: Cell temperature

Click to reveal the calculation
  1. NOCT rule.

    ✅

  2. Against STC. The cells are 30 °C above the test temperature of 25 °C. No air temperature that is normal at this site would bring cells in full sun down to 25 °C. ✅

Step 2: Power of one module, two ways

Click to reveal the calculation
  1. Light factor. . ✅

  2. Heat factor. . ✅

  3. By the data sheet coefficient.

    ✅

  4. By the model. module_current() at 800 W/m² and 55 °C gives A, V, V, A and W, with a fill factor of 0.773. ✅

  5. Compare. The model is 0.4 percent above the data sheet rule. The two methods agree. ✅

  6. Where the loss is. The current fell from 13.13 to 10.54 A, almost exactly the factor 0.80 of the light. The voltage at maximum power fell from 41.89 to 37.51 V, a loss of 10.5 percent, and nearly all of that is heat. ✅

Step 3: The array and the meter

Click to reveal the calculation
  1. At the modules. W, so 7.09 kW of direct current power. ✅

  2. At the meter.

    That is 65 percent of the nameplate 9.9 kW. ✅

  3. Split the gap. The gap is kW. Light below the test value takes kW. Heat takes kW. Dirt, wiring, mismatch and the inverter take kW. ✅

  4. The reading of six. With the same air temperature and the same factors, the meter shows exactly 6.00 kW when the irradiance is 736 W/m². Thin haze at noon is enough. ✅

  5. The best moment of a clear day. The clear day of this course peaks at 916.7 W/m². With the air at 30 °C the same calculation gives 7.31 kW at the meter. The array of 9.9 kWp does not show more than about three quarters of its nameplate at any time of that day. ✅

Step 4: Check with limiting cases

Click to reveal the check
  1. Back to STC. With W/m² and °C both factors are 1, and the rule returns 550.0 W. ✅

  2. Weaker light. At 500 W/m² and air at 30 °C the cells are at 45.6 °C. The data sheet rule gives 255.1 W and the model gives 251.1 W, which is 1.6 percent lower. The rule ignores the small loss of voltage in weak light, so it is slightly optimistic there. ✅

  3. The two coefficients. From 25 to 60 °C at full light the model loses 0.323 percent per °C, and the data sheet says 0.35. The model sets its diode so that follows the data sheet coefficient at each temperature, and its power coefficient is then a result, not an input. The data sheet value is measured on real modules. A difference of this size between a simple model and a data sheet is normal, and for sizing the data sheet decides. ✅

7.09 kWat themodules7.92 kW6.47 kWat themeterNameplate9.9 kWp(STC)light800 of1000heat: cellsat55°Cdirt,wiring,inverter
From the label to the meter at noon

Verify It in Python



The script holds the course model of the module. It prints the curve at STC, the effect of the two resistances, the table of light and heat, and the hot roof calculation, and it saves a plot of the I-V and P-V curves for three conditions.

iv_curve.py
"""The I-V curve of the example 550 W module: maximum power point, fill factor, heat and light."""
import numpy as np
from scipy.optimize import brentq, minimize_scalar
import matplotlib.pyplot as plt
K_B, Q = 1.380649e-23, 1.602176634e-19
def module_current(v, g=1000.0, t_cell=25.0, ns=72, n=1.1, rs=0.14, rsh=400.0,
isc_stc=13.90, voc_stc=49.90, a_isc=0.0005, b_voc=-0.0027):
"""Current (A) of the example 550 W module at voltage v (V), irradiance g (W/m2)
and cell temperature t_cell (deg C). Single-diode model."""
tk = t_cell + 273.15
vt = ns * n * K_B * tk / Q
iph = isc_stc * (g / 1000.0) * (1 + a_isc * (t_cell - 25.0))
voc_t = voc_stc * (1 + b_voc * (t_cell - 25.0))
i0 = (isc_stc * (1 + a_isc * (t_cell - 25.0)) - voc_t / rsh) / (np.exp(voc_t / vt) - 1)
f = lambda i: iph - i0 * (np.exp((v + i * rs) / vt) - 1) - (v + i * rs) / rsh - i
return brentq(f, -200.0, iph + 1.0)
def curve_points(g=1000.0, t_cell=25.0, **kw):
"""Short-circuit current, open-circuit voltage, maximum power point and fill factor."""
isc = module_current(0.0, g, t_cell, **kw)
voc = brentq(lambda v: module_current(v, g, t_cell, **kw), 1.0, 55.0)
best = minimize_scalar(lambda v: -v * module_current(v, g, t_cell, **kw),
bounds=(0.5 * voc, voc), method="bounded",
options={"xatol": 1e-6})
vmp = best.x
imp = module_current(vmp, g, t_cell, **kw)
return isc, voc, vmp, imp, vmp * imp, vmp * imp / (voc * isc)
def cell_temperature(t_air, g, noct=45.0):
"""Cell temperature (deg C) from the air temperature and irradiance by the NOCT rule."""
return t_air + (noct - 20.0) * g / 800.0
AREA, P_STC, GAMMA = 2.58, 550.0, -0.0035
# ---------- Application 1: the module at standard test conditions ----------
print("Application 1: the example module at STC (1000 W/m2, cell at 25 deg C)")
vt = 72 * 1.1 * K_B * 298.15 / Q
print(f" thermal voltage of one cell {1000 * K_B * 298.15 / Q:.2f} mV, "
f"n Ns Vt for the module {vt:.3f} V")
print(" V (V) I (A) P (W)")
for v in (0, 10, 20, 30, 35, 38, 40, 42, 44, 46, 48, 49.9):
i = max(module_current(v), 0.0)
print(f" {v:5.1f} {i:6.2f} {v * i:6.1f}")
isc, voc, vmp, imp, pmp, ff = curve_points()
print(f" Isc {isc:.2f} A, Voc {voc:.2f} V, Vmp {vmp:.2f} V, Imp {imp:.2f} A, "
f"Pmp {pmp:.1f} W, FF {ff:.3f}")
i0 = (13.90 - 49.90 / 400.0) / (np.exp(49.90 / vt) - 1)
vd = vmp + imp * 0.14
print(f" saturation current {i0:.3e} A; at the maximum power point the junction is at "
f"{vd:.2f} V,")
print(f" diode current {i0 * (np.exp(vd / vt) - 1):.3f} A, shunt current {vd / 400.0:.3f} A, "
f"terminal current {13.90 - i0 * (np.exp(vd / vt) - 1) - vd / 400.0:.2f} A")
print(f" data sheet: FF {41.9 * 13.1 / (49.90 * 13.90):.3f}, Vmp x Imp {41.9 * 13.1:.1f} W, "
f"efficiency {100 * P_STC / (1000 * AREA):.1f} %")
print(f" Vmp/Voc {vmp / voc:.3f}, Imp/Isc {imp / isc:.3f}, "
f"load resistance at the point {vmp / imp:.2f} ohm")
for r in (1.0, 3.19, 10.0):
v = brentq(lambda x: module_current(x) - x / r, 0.0, 60.0)
print(f" a resistor of {r:5.2f} ohm sits at {v:5.2f} V, {v / r:5.2f} A, {v * v / r:5.1f} W")
print(" what the two resistances do (STC):")
for name, kw in (("as built, Rs 0.14, Rsh 400", {}),
("Rs doubled to 0.28", {"rs": 0.28}),
("Rsh cut to 40", {"rsh": 40.0}),
("ideal, Rs 0, Rsh very large", {"rs": 0.0, "rsh": 1e9})):
a = curve_points(**kw)
print(f" {name:28s} Isc {a[0]:.2f} A, Voc {a[1]:.2f} V, Pmp {a[4]:.1f} W, FF {a[5]:.3f}")
# ---------- Light and heat ----------
print("Light and heat")
print(" G Tcell Isc Voc Vmp Imp Pmp FF")
for g, t in ((1000, 25), (800, 45), (1000, 60), (200, 25), (1000, 10)):
a = curve_points(g, t)
print(f" {g:5d} {t:5d} {a[0]:5.2f} {a[1]:5.2f} {a[2]:5.2f} {a[3]:5.2f} "
f"{a[4]:5.1f} {a[5]:.3f}")
p25, p60, p200 = curve_points()[4], curve_points(1000, 60)[4], curve_points(200, 25)[4]
print(f" power coefficient of the model, 25 to 60 deg C: "
f"{100 * (p60 / p25 - 1) / 35:.3f} % per deg C (data sheet -0.35)")
print(f" at 200 W/m2 the module gives {100 * p200 / p25:.1f} % of its STC power "
f"from 20 % of the light")
# ---------- Application 2: a hot roof at noon ----------
G, T_AIR, N_MOD = 800.0, 30.0, 18
tc = cell_temperature(T_AIR, G)
p_sheet = P_STC * G / 1000.0 * (1 + GAMMA * (tc - 25.0))
isc, voc, vmp, imp, p_model, ff = curve_points(G, tc)
print("Application 2: a hot roof, 800 W/m2, air at 30 deg C")
print(f" cell temperature {tc:.1f} deg C, {tc - 25:.0f} deg C above STC")
print(f" by the data sheet coefficient: light factor {G / 1000:.2f}, "
f"heat factor {1 + GAMMA * (tc - 25):.3f}, power {p_sheet:.1f} W")
print(f" by the model: Isc {isc:.2f} A, Voc {voc:.2f} V, Vmp {vmp:.2f} V, Imp {imp:.2f} A, "
f"Pmp {p_model:.1f} W, FF {ff:.3f}")
print(f" model against data sheet: {100 * (p_model / p_sheet - 1):+.1f} %")
dc = N_MOD * p_sheet / 1000.0
SOIL, WIRE, INV = 0.97, 0.97, 0.97 # stated example factors
ac = dc * SOIL * WIRE * INV
print(f" array of {N_MOD}: nameplate {N_MOD * P_STC / 1000:.1f} kWp, "
f"{dc:.2f} kW DC by the data sheet, {N_MOD * p_model / 1000:.2f} kW by the model")
print(f" with soiling {SOIL}, wiring and mismatch {WIRE}, inverter {INV}: {ac:.2f} kW AC, "
f"{100 * ac / (N_MOD * P_STC / 1000):.0f} % of nameplate")
print(f" share of the gap: light {N_MOD * P_STC / 1000 * (1 - G / 1000):.2f} kW, "
f"heat {N_MOD * P_STC / 1000 * G / 1000 - dc:.2f} kW, other {dc - ac:.2f} kW")
ac_at = lambda g: (N_MOD * P_STC / 1000.0 * g / 1000.0
* (1 + GAMMA * (cell_temperature(T_AIR, g) - 25.0)) * SOIL * WIRE * INV)
g6 = brentq(lambda g: ac_at(g) - 6.0, 300.0, 1000.0)
print(f" the meter shows 6.00 kW at {g6:.0f} W/m2; at the clear day peak of 916.7 W/m2 "
f"it shows {ac_at(916.7):.2f} kW")
tc5 = cell_temperature(T_AIR, 500.0)
print(f" check at 500 W/m2: cell {tc5:.1f} deg C, data sheet "
f"{P_STC * 0.5 * (1 + GAMMA * (tc5 - 25)):.1f} W, model {curve_points(500.0, tc5)[4]:.1f} W")
print(f" check at STC: the rule gives {P_STC * 1.0 * (1 + GAMMA * 0):.1f} W")
# ---------- Plot ----------
fig, ax = plt.subplots(2, 1, figsize=(8, 8), sharex=True)
for g, t, name in ((1000, 25, "1000 W/m2, 25 C (STC)"), (800, 55, "800 W/m2, 55 C (hot roof)"),
(200, 25, "200 W/m2, 25 C")):
voc = curve_points(g, t)[1]
vs = np.linspace(0.0, voc, 200)
cur = np.array([module_current(v, g, t) for v in vs])
a = curve_points(g, t)
ax[0].plot(vs, cur, label=name)
ax[0].plot(a[2], a[3], "ko")
ax[1].plot(vs, vs * cur, label=name)
ax[1].plot(a[2], a[4], "ko")
ax[0].set_ylabel("current (A)")
ax[0].set_title("I-V curves of the example module, maximum power points marked")
ax[0].legend()
ax[1].set_xlabel("voltage (V)")
ax[1].set_ylabel("power (W)")
ax[1].set_title("P-V curves")
fig.tight_layout()
fig.savefig("iv_curve.png", dpi=120)
print("Saved iv_curve.png")

Expected output

Application 1: the example module at STC (1000 W/m2, cell at 25 deg C)
thermal voltage of one cell 25.69 mV, n Ns Vt for the module 2.035 V
V (V) I (A) P (W)
0.0 13.90 0.0
10.0 13.87 138.7
20.0 13.85 276.9
30.0 13.82 414.5
35.0 13.78 482.4
38.0 13.70 520.5
40.0 13.53 541.0
42.0 13.09 549.9
44.0 12.05 530.1
46.0 9.80 451.0
48.0 5.74 275.5
49.9 0.00 0.0
Isc 13.90 A, Voc 49.90 V, Vmp 41.89 V, Imp 13.13 A, Pmp 549.9 W, FF 0.793
saturation current 3.083e-10 A; at the maximum power point the junction is at 43.72 V,
diode current 0.662 A, shunt current 0.109 A, terminal current 13.13 A
data sheet: FF 0.791, Vmp x Imp 548.9 W, efficiency 21.3 %
Vmp/Voc 0.839, Imp/Isc 0.945, load resistance at the point 3.19 ohm
a resistor of 1.00 ohm sits at 13.86 V, 13.86 A, 192.1 W
a resistor of 3.19 ohm sits at 41.88 V, 13.13 A, 549.9 W
a resistor of 10.00 ohm sits at 48.34 V, 4.83 A, 233.7 W
what the two resistances do (STC):
as built, Rs 0.14, Rsh 400 Isc 13.90 A, Voc 49.90 V, Pmp 549.9 W, FF 0.793
Rs doubled to 0.28 Isc 13.89 A, Voc 49.90 V, Pmp 525.9 W, FF 0.759
Rsh cut to 40 Isc 13.85 A, Voc 49.90 V, Pmp 512.6 W, FF 0.742
ideal, Rs 0, Rsh very large Isc 13.90 A, Voc 49.90 V, Pmp 578.6 W, FF 0.834
Light and heat
G Tcell Isc Voc Vmp Imp Pmp FF
1000 25 13.90 49.90 41.89 13.13 549.9 0.793
800 45 11.23 46.72 38.92 10.53 409.7 0.781
1000 60 14.14 45.18 36.96 13.20 487.8 0.764
200 25 2.78 46.56 39.99 2.55 102.1 0.789
1000 10 13.79 51.92 44.03 13.09 576.2 0.805
power coefficient of the model, 25 to 60 deg C: -0.323 % per deg C (data sheet -0.35)
at 200 W/m2 the module gives 18.6 % of its STC power from 20 % of the light
Application 2: a hot roof, 800 W/m2, air at 30 deg C
cell temperature 55.0 deg C, 30 deg C above STC
by the data sheet coefficient: light factor 0.80, heat factor 0.895, power 393.8 W
by the model: Isc 11.28 A, Voc 45.35 V, Vmp 37.51 V, Imp 10.54 A, Pmp 395.3 W, FF 0.773
model against data sheet: +0.4 %
array of 18: nameplate 9.9 kWp, 7.09 kW DC by the data sheet, 7.12 kW by the model
with soiling 0.97, wiring and mismatch 0.97, inverter 0.97: 6.47 kW AC, 65 % of nameplate
share of the gap: light 1.98 kW, heat 0.83 kW, other 0.62 kW
the meter shows 6.00 kW at 736 W/m2; at the clear day peak of 916.7 W/m2 it shows 7.31 kW
check at 500 W/m2: cell 45.6 deg C, data sheet 255.1 W, model 251.1 W
check at STC: the rule gives 550.0 W
Saved iv_curve.png

Common Mistakes



  • Multiplying by to get the power. These two values never occur together. The power is , lower by the fill factor.
  • Expecting nameplate power on a roof. Nameplate is at 1,000 W/m² and a cell at 25 °C. At 800 W/m² and 55 °C the example module gives 394 W, not 550 W.
  • Putting the air temperature into the power coefficient. The coefficient applies to the cell temperature, which in full sun is 25 to 30 °C above the air.
  • Believing that heat is good for a solar module because hot places are sunny. Light raises the power and heat lowers it. The best output comes on a cold, bright day.
  • Thinking that half the light gives half the voltage. Light moves the current. The voltage falls only a few percent, which is why a module can show nearly full voltage in poor light and still deliver almost no power.
  • Judging a module by a voltage reading at open circuit. A module with a high series resistance or a poor shunt resistance can show a normal and a poor maximum power.

Summary



  • A solar cell behaves as a source of current, proportional to the light, with a diode across it. The single-diode equation adds a series and a shunt resistance and describes the whole I-V curve.
  • The curve runs from at zero voltage to at zero current. The maximum power point lies at the knee, and the load decides where on the curve the module works.
  • The fill factor measures how square the curve is. The example module has 549.9 W and a fill factor of 0.793 at STC.
  • Light moves the current in proportion and the voltage only a little. Heat moves the voltage: the power falls by about 0.35 percent for each °C of cell temperature above 25 °C.
  • The cell temperature is . At 800 W/m² and air at 30 °C it is 55 °C.
  • On that roof one module gives 393.8 W by the data sheet rule and 395.3 W by the model. The array of 9.9 kWp gives 7.09 kW at the modules and about 6.47 kW at the meter.

Exercises



1. A module label gives V, A, V and A. Find the maximum power and the fill factor.

Answer

W. .

2. A module has NOCT = 45 °C. The air is at 35 °C and the plane-of-array irradiance is 900 W/m². Find the cell temperature.

Answer

°C.

3. A module of 400 W has a power coefficient of % per °C. Find its power at 900 W/m² with the cells at 63.1 °C.

Answer

W.

4. The example module has V at STC and a voltage coefficient of % per °C. Find its open-circuit voltage at full light with the cells at 65 °C. Then say in which direction the value moves on a cold morning.

Answer

V. On a cold morning the cells are below 25 °C and the open-circuit voltage is above 49.90 V. The highest voltage of a module occurs when it is cold.

5. Use module_current() to find the maximum power of the example module at 600 W/m² with the cells at 50 °C. Compare with the data sheet rule.

Answer

The model gives V, A and W. The rule gives W. The model is 0.7 percent lower, because the rule ignores the loss of voltage in weaker light.

References



  • G. M. Masters, Renewable and Efficient Electric Power Systems, 2nd edition, Wiley, 2013.
  • R. A. Messenger and A. Abtahi, Photovoltaic Systems Engineering, 4th edition, CRC Press, 2017.
  • J. A. Duffie and W. A. Beckman, Solar Engineering of Thermal Processes, 4th edition, Wiley, 2013.
  • IEC 61215, Terrestrial photovoltaic (PV) modules: Design qualification and type approval (named here as the standard under which modules are tested).


© 2021-2026 SiliconWit®. All rights reserved.
Predict first

A module shows 49.90 V at its open terminals in full light of 1,000 W/m². A cloud cuts the light to one fifth, 200 W/m², and the cells stay at the same temperature. What happens to the voltage at the open terminals?

See it: light moves the current, heat moves the voltage

Maximum power Pmp
Voltage at maximum power Vmp
Current at maximum power Imp
Short-circuit current Isc
Open-circuit voltage Voc
Fill factor FF

The curves are the course model of the example 550 W module, the same single-diode equation that module_current() solves. At the start the figure shows the hot roof of this lesson: 800 W/m² with the cells at 55 °C. The faint dashed curve is the same module at standard test conditions, 1,000 W/m² and 25 °C, where the label values are measured. Move the irradiance and watch the flat part of the current rise and fall while the voltage end hardly moves. Move the cell temperature and watch the voltage end slide while the current hardly moves. The temperature here is the temperature of the cells, not of the air: in full sun the cells are 25 to 30 °C hotter than the air. The model is a fit to the data sheet points of an example module. For real equipment the maker's data sheet decides.

Check yourself

Three questions. Each wrong choice is a mistake people really make, so read the note after you answer.

1. A module label gives an open-circuit voltage of 40.0 V, a short-circuit current of 10.0 A and a fill factor of 0.78. What is its maximum power?

2. The light stays at 800 W/m² and the cells of the example module warm from 45 °C to 55 °C. What happens on the curve?

3. The air is at 30 °C and the irradiance is 1,000 W/m². The NOCT of the module is 45 °C. Which cell temperature belongs in the figure?

pump: the lightrelief valve: the diodeoutlet: the terminals Shut the outlet: pressure rises until the valve takes all the flow.
1 Ω: 192 W3.19 Ω: 550 W10 Ω: 234 W currentvoltage
Watch it build: two resistances, two places on the curve
IV Isc 13.9 A Voc 49.9 V as built549.9 WFF 0.793 Rs doubled:the knee leans,Voc stays Rs 0.28 Ω525.9 WFF 0.759 Rsh cut to 40 Ω:the flat part slopes Rsh 40 Ω512.6 WFF 0.742 ideal578.6 W5 % more FF low, Voc and Iscon the label: look atRs or Rsh
  1. The example module at STC: 549.9 W at its maximum power point, fill factor 0.793.
  2. Series resistance doubled to 0.28 Ω: the knee leans to lower voltage, 525.9 W, fill factor 0.759.
  3. Shunt resistance cut to 40 Ω: the flat part slopes down, 512.6 W, fill factor 0.742.
  4. The ideal cell gives 578.6 W. A fill factor that fell with Voc and Isc unchanged points to Rs or Rsh.
light 800 W/m² test: 1000 W/m² cells at 55 °C test: 25 °C outside air at 30 °C roof sheet label: 550 W on the roof: about 394 W
A module on the roof at noon against the test conditions
Iph D Rsh Rs + − I V Iph: current made by the light D: the junction, acting as a diode Rs: fingers, ribbons and silicon in the path Rsh: small leakage paths across the junction
The single-diode model of a cell
0 10 20 30 41.9 Voc 49.9 0 5 10 13.9 voltage V current I, A maximum power point 41.9 V, 13.1 A: 549.9 W Isc 13.9 A current stays near Isc, then falls fast near open circuit
The I-V curve of the example module at STC
Nameplate (STC) 9.9 kWp −1.98 light 800 of 1000 7.92 kW −0.83 heat: cells at 55 °C 7.09 kW at the modules −0.62 dirt, wiring, inverter 6.47 kW at the meter the gap of 3.43 kW: light 1.98, heat 0.83, the rest 0.62