Performance ratio
Performance Ratio and Losses
On this page
An owner sees that September gave half of January’s energy. Was September cloudy, or did something break? The energy figure cannot answer, because it mixes how much light arrived with how well the system used it. A second owner sees a good month and relaxes, while dust has already taken a tenth of the output. Both need one number that removes the weather from the reading. This lesson builds that number, the performance ratio, and the chain of losses that explains its value. #PerformanceRatio #SolarLosses #EnergyYield
Learning Objectives
By the end of this lesson, you will be able to:
- Name the losses between the light on the array and the energy at the inverter output, in the order in which they occur
- Calculate the performance ratio, the specific yield and the capacity factor of a system from its records
- Build a loss table of stated factors and multiply it to an expected performance ratio and a yearly energy
- Explain why the performance ratio is a fairer measure of health than energy alone, and what a temperature-corrected value adds
- Read a year of monthly performance ratios and point to the months that need a reason
Real-World System Problem: One array, twelve different months
The site of this course has 18 modules of 550 W on a workshop roof near the equator: 9.9 kWp of nameplate power. Nameplate power is defined at standard test conditions (STC: 1,000 W/m², cells at 25 °C), and a hot roof never meets them. So “how much should this array give?” has no answer in kilowatts alone, only for a given amount of light after a known list of losses.
The site keeps two daily records: the plane-of-array insolation
Fundamental Theory: From reference energy to real energy
The reference energy
Imagine an array with no losses: every module gives exactly its nameplate power at 1,000 W/m² and in proportion at any other irradiance. An insolation of 1 kWh/m² is one peak sun hour, in which the perfect array gives
with
The performance ratio
The performance ratio is the real energy divided by the reference energy.
The performance ratio collects every loss between the light and the output into one number: 0.78 means that 22 percent of the reference energy did not arrive. Because the insolation is in the denominator, a cloudy month and a sunny month of a healthy system give nearly the same value. That is the whole use of the ratio, as litres per 100 km judges a car’s engine whatever the length of the trip.
Two rules keep it honest. The insolation must be measured in the plane of the array, not on a horizontal surface or from a long-term table. And the energy and the insolation must cover exactly the same period.
Specific yield and capacity factor
Two other figures appear in reports, and both are easy to confuse with the performance ratio.
The specific yield is the energy for each kilowatt of nameplate power:
It allows arrays of different size to be compared. Dividing the specific yield by the insolation gives the performance ratio:
The capacity factor is the energy divided by what the array would give at nameplate power for every hour of the period, day and night:
Solar capacity factors are low, often below 20 percent, because the sun is down half the time. Some reports divide by the inverter rating instead of the array nameplate, so always say which is used; this course uses the array.
The specific yield and the capacity factor both rise in a sunny year and fall in a cloudy one: they describe the site and the system together. Only the performance ratio separates the system from the site.
| Figure | Formula | Changes with the weather? | What it is for |
|---|---|---|---|
| Energy | Yes | The bill | |
| Specific yield | Yes | Comparing arrays of different size | |
| Capacity factor | Yes | Comparing with other power sources | |
| Performance ratio | Only a little | The health of the system |
The loss chain
The losses occur in a fixed order from the glass to the meter, each taking a share of what the stage before passed on, like a pipe that leaks a little at every joint.
Reflection and weak light. Light at a flat angle reflects from the glass, and a module converts weak light a little less well than strong light, as the I-V curve showed.
Temperature. Cells in the sun are 20 to 30 °C above the air, and the power falls by the coefficient
Module below its label, and ageing. A module may leave the factory slightly above or below its label; silicon modules lose a little output in their first weeks in the light, then a small amount each year. The maker’s data sheet and warranty give the figures.
Soiling. Dust, pollen and bird droppings block light. The loss grows day by day in dry weather and returns to near zero when it rains.
Mismatch and wiring. Modules in a string are never identical, and the weakest limits the current. Cables and connectors lose power as heat in proportion to the square of the current.
Inverter. Its efficiency depends on the load, a few percent below 1 over most of the range.
Clipping. When the array can give more than the inverter rating, the inverter holds its limit and the surplus is not produced.
Availability. Hours when the system is stopped (a fault, a repair, a grid failure with nowhere to send the power) count fully as loss. A hybrid system does the same when the battery is full, the load small and export not allowed: the inverter moves the array away from its maximum power point, and a healthy array shows a lower performance ratio.
Factors multiply
Each loss is written as a factor, the share of the energy that passes: a soiling loss of 3 percent is a factor of 0.97. Because each stage acts on what the stage before passed on, the factors multiply:
Performance ratio from a loss table
Each
The common mistake is to add the losses. Eight losses that sum to 24 percent leave more than 76 percent, because each later loss takes its share from an amount already smaller. The difference is small for small losses and grows with them.
A loss table is a statement of expectation: every line is an assumption or a data sheet value until it is measured. When the measured performance ratio is below the table, something in the chain is worse than assumed, and the table says where to look.
The temperature factor over a day
The temperature factor of a moment is
For a clear day whose irradiance follows a smooth curve,
Temperature-corrected performance ratio
The ordinary performance ratio still contains the weather in one way: a hot month gives a lower value than a cool month for the same healthy system. To compare months or sites fairly, the temperature loss can be removed by multiplying the reference energy of each interval by its temperature factor:
An example shows the effect. A hot month has
What a good value looks like
Yearly performance ratios of well-built systems are commonly reported between about 0.75 and 0.85, hot sites in the lower part and cool sites in the upper part, for the reason just shown. These figures are common experience, not a limit from any standard. A value is judged against the loss table and the history of its own system, not against another site.
Application 1: A loss table for the site
Step 1: Temperature factor
Click to reveal the calculation
-
Energy-weighted cell temperature.
✅
-
Temperature factor.
Heat alone takes 8.6 percent of the reference energy at this site. ✅
Step 2: The table
Click to reveal the calculation
-
Reference energy of a year.
kWh/m². ✅
-
Multiply stage by stage.
Stage Factor Running product Energy after (kWh) Lost here (kWh) Temperature 0.914 0.9140 18,165 1,709 Reflection and weak light 0.97 0.8866 17,620 545 Module below label, first ageing 0.98 0.8688 17,268 352 Soiling 0.97 0.8428 16,750 518 Wiring and mismatch 0.97 0.8175 16,247 502 Inverter 0.97 0.7930 15,760 487 Clipping 0.995 0.7890 15,681 79 Availability 0.99 0.7811 15,524 157 ✅
-
Performance ratio.
✅
-
Read the column of losses. Temperature takes 1,709 kWh, more than the next three losses together. The same factor of 0.97 takes 545 kWh near the top of the table and 487 kWh lower down, because it acts on a smaller amount. ✅
Step 3: Yearly energy, specific yield and capacity factor
Click to reveal the calculation
-
Yearly energy.
That is 42.5 kWh on a mean day, and 4,350 kWh a year below the reference energy. ✅
-
Specific yield.
✅
-
Capacity factor.
The array gives 17.9 percent of what its nameplate would give if it ran at full power all year. ✅
Step 4: Check the table
Click to reveal the check
-
Against a sum of losses. The eight losses add to
percent. The true loss is percent. Adding would understate the energy by 2.2 percent of the reference, which is about 440 kWh a year. ✅ -
Against the specific yield.
. The same performance ratio comes back. ✅ -
Against the noon reading. At noon with 800 W/m² and air at 30 °C, the same array showed 6.47 kW from a reference of
kW: a ratio of 0.817 at that moment, with a heat factor of 0.895 and three factors of 0.97. The yearly table has a milder heat factor (0.914, because mornings and evenings are cooler) and four more losses that one clean noon reading did not count, so a lower yearly value is expected. ✅ -
Against the earlier estimate. The round performance ratio of 0.75 used when the resource was studied gave 14,906 kWh a year. The table gives 15,524 kWh, 4 percent more: the round value was on the careful side. ✅
-
Without soiling. Dividing the soiling factor out gives
. This is what the table expects from a clean array, for example on the day after rain. ✅
Application 2: One year of records, month by month
Step 1: Monthly values
Click to reveal the calculation
-
Sum each month, then divide. For each month, add the daily insolation and the daily energy, then apply
. Month Days (kWh/m²) (kWh) Rain days Jan 0 to 30 187.8 1,432.9 0.771 1 Feb 31 to 58 173.2 1,218.7 0.711 0 Mar 59 to 89 178.7 1,313.7 0.743 8 Apr 90 to 119 151.5 1,203.8 0.803 16 May 120 to 150 143.0 1,128.4 0.797 9 Jun 151 to 180 163.1 1,242.7 0.769 0 Jul 181 to 211 155.1 1,156.3 0.753 2 Aug 212 to 242 151.2 1,156.2 0.772 0 Sep 243 to 272 158.5 718.0 0.458 1 Oct 273 to 303 150.3 1,175.1 0.789 10 Nov 304 to 333 144.8 1,143.9 0.798 15 Dec 334 to 364 176.0 1,379.5 0.792 7 ✅
-
One month by hand. April:
. ✅ -
Energy against performance ratio. January has the most energy of the year and a performance ratio of 0.771. April has 16 percent less energy and the best performance ratio, 0.803. January had more light. April had the cleaner array. ✅
Step 2: The year
Click to reveal the calculation
-
Sums. The year has
kWh/m² (a mean of 5.297 a day) and kWh. ✅ -
Performance ratio.
✅
-
Specific yield and capacity factor.
kWh/kWp and . ✅ -
Against the design. This particular year had 5.297 peak sun hours against the design 5.5: 3.7 percent less light. The energy is 8.1 percent below the 15,524 kWh of the table, so less light explains less than half; the rest is the performance ratio, 0.746 against 0.781. ✅
Step 3: The months where the performance ratio falls
Click to reveal the reading
-
The wet months. April, May, October, November and December are between 0.789 and 0.803. Rain fell on 7 to 16 days of each. These values are close to the 0.805 that the table expects from a clean array. ✅
-
The dry months. January (0.771), June (0.769), July (0.753) and August (0.772) had two rain days or fewer. They are 2 to 5 hundredths below the wet months, and the difference appears when the rain stops. That is the pattern of soiling. ✅
-
February. At 0.711 it is the lowest month with a working array, after no rain in February and one day in January. At the table value of 0.781 it would have given 1,340 kWh; it gave 1,219 kWh, 121 kWh less. March recovers to 0.743 as the rain begins on day 75. ✅
-
September. At 0.458 it is far outside anything dust can do. The daily record shows the break: days 243 to 249 have a performance ratio of 0.731, days 250 to 271 have 0.361, almost exactly half, and half of this array is one of its two strings. At the table value the month would have given 1,226 kWh; it gave 718 kWh. ✅
-
Check: the year without the fault. Without days 250 to 271 the performance ratio of the year is 0.770. The fault of 22 days lowered the yearly value from 0.770 to 0.746. The remaining gap from 0.770 to the table value of 0.781 is about the size of the extra soiling of the dry months. ✅
-
Check: the average trap. The mean of the twelve monthly values is 0.746 and the mean of the 365 daily values is 0.748. They are close to the true 0.746 here because the months have similar light; with unequal months the gap grows, and only the ratio of the sums is correct. ✅
Verify It in Python
The script builds the loss table of Application 1 and the monthly table of Application 2, and saves a plot of monthly energy and monthly performance ratio.
"""Performance ratio of the 9.9 kWp site: a loss table, then one year of records by month."""import numpy as npimport matplotlib.pyplot as plt
def year_of_yield(seed=11, kwp=9.9): """One year of daily records for the 9.9 kWp array: day number, plane-of-array insolation (kWh/m2), array energy at the inverter output (kWh). True model: base performance ratio 0.80; soiling loses 0.25 % a day since the last rain or wash, up to 12 %; rain on random days in two wet seasons; a string fault from day 250 to day 271 removes half the array; noise 2 %.""" rng = np.random.default_rng(seed) d = np.arange(365) wet = ((d >= 75) & (d < 150)) | ((d >= 285) & (d < 345)) h = 5.6 + 0.6 * np.cos(2 * np.pi * (d - 40) / 365) - 0.9 * wet + rng.normal(0, 0.7, 365) h = np.clip(h, 1.5, 7.5) rain = rng.random(365) < np.where(wet, 0.45, 0.03) soil = np.zeros(365); s = 0.0 for i in range(365): s = 0.0 if rain[i] else min(s + 0.0025, 0.12) soil[i] = s pr = 0.80 * (1 - soil) * (1 + rng.normal(0, 0.02, 365)) pr[250:272] *= 0.5 e = kwp * h * pr return d, h.round(2), e.round(1), rain
KWP, GAMMA, NOCT = 9.9, -0.0035, 45.0
# ---------- Application 1: the loss table ----------H_MEAN, T_AIR, G_WEIGHTED = 5.5, 28.0, 687.5t_cell = T_AIR + (NOCT - 20.0) * G_WEIGHTED / 800.0f_temp = round(1 + GAMMA * (t_cell - 25.0), 3)factors = (("temperature", f_temp), ("reflection and weak light", 0.97), ("module below label, first ageing", 0.98), ("soiling", 0.97), ("wiring and mismatch", 0.97), ("inverter", 0.97), ("clipping", 0.995), ("availability", 0.99))e_ref = KWP * H_MEAN * 365print("Application 1: the loss table")print(f" energy-weighted cell temperature {t_cell:.1f} deg C, temperature factor {f_temp:.3f}")print(f" reference energy {e_ref:,.0f} kWh a year ({H_MEAN * 365:,.1f} kWh/m2)")print(" stage factor product energy lost here")run, energy = 1.0, e_reffor name, f in factors: run *= f print(f" {name:34s} {f:5.3f} {run:6.4f} {energy * f:6,.0f} {energy * (1 - f):5,.0f}") energy *= fpr_table = runprint(f" performance ratio {pr_table:.3f}; yearly energy {energy:,.0f} kWh; " f"lost {e_ref - energy:,.0f} kWh")print(f" specific yield {energy / KWP:,.0f} kWh/kWp; capacity factor " f"{100 * energy / (KWP * 8760):.1f} %; mean day {energy / 365:.1f} kWh")print(f" adding the losses gives {100 * sum(1 - f for _, f in factors):.1f} %, " f"the true loss is {100 * (1 - pr_table):.1f} %")print(f" without soiling the table gives {pr_table / 0.97:.3f}; " f"at a performance ratio of 0.75 the year is {KWP * H_MEAN * 365 * 0.75:,.0f} kWh")print(f" temperature-corrected example: 0.760 at 52 deg C gives " f"{0.760 / (1 + GAMMA * 27):.3f}, 0.790 at 44 deg C gives {0.790 / (1 + GAMMA * 19):.3f}")
# ---------- Application 2: one year of records ----------d, h, e, rain = year_of_yield()names = ("Jan", "Feb", "Mar", "Apr", "May", "Jun", "Jul", "Aug", "Sep", "Oct", "Nov", "Dec")length = (31, 28, 31, 30, 31, 30, 31, 31, 30, 31, 30, 31)print("Application 2: one year of records")print(" month days H (kWh/m2) E (kWh) PR rain days")start, pr_month, e_month = 0, [], []for name, n in zip(names, length): sl = slice(start, start + n) pr_m = e[sl].sum() / (KWP * h[sl].sum()) pr_month.append(pr_m); e_month.append(e[sl].sum()) print(f" {name} {start:3d} to {start + n - 1:3d} {h[sl].sum():6.1f} " f"{e[sl].sum():7.1f} {pr_m:.3f} {rain[sl].sum():3d}") start += npr_year = e.sum() / (KWP * h.sum())print(f" year: insolation {h.sum():,.1f} kWh/m2 (mean {h.mean():.3f} a day), " f"energy {e.sum():,.0f} kWh, PR {pr_year:.3f}")print(f" specific yield {e.sum() / KWP:,.0f} kWh/kWp, capacity factor " f"{100 * e.sum() / (KWP * 8760):.1f} %, rain days {rain.sum()}")print(f" light against the design mean: {100 * (h.sum() / (H_MEAN * 365) - 1):+.1f} %; " f"energy against the table: {100 * (e.sum() / energy - 1):+.1f} %")print(f" mean of the 12 monthly values {np.mean(pr_month):.3f}, " f"mean of the 365 daily values {np.mean(e / (KWP * h)):.3f}")healthy = np.ones(365, bool); healthy[250:272] = Falseprint(f" September, days 243 to 249: PR {e[243:250].sum() / (KWP * h[243:250].sum()):.3f}; " f"days 250 to 271: PR {e[250:272].sum() / (KWP * h[250:272].sum()):.3f}")print(f" year without days 250 to 271: PR " f"{e[healthy].sum() / (KWP * h[healthy].sum()):.3f}")print(f" February at the table value would give {KWP * h[31:59].sum() * pr_table:,.0f} kWh; " f"September would give {KWP * h[243:273].sum() * pr_table:,.0f} kWh")
# ---------- Plot ----------fig, ax = plt.subplots(2, 1, figsize=(8, 7), sharex=True)ax[0].bar(names, e_month, color="tab:orange")ax[0].set_ylabel("energy (kWh)")ax[0].set_title("Monthly energy and monthly performance ratio of the 9.9 kWp array")ax[1].bar(names, pr_month, color="tab:blue")ax[1].axhline(pr_table, color="k", ls="--", label=f"loss table {pr_table:.3f}")ax[1].axhline(pr_year, color="r", ls=":", label=f"year {pr_year:.3f}")ax[1].set_ylabel("performance ratio")ax[1].set_ylim(0.3, 0.9)ax[1].legend(loc="lower left")fig.tight_layout()fig.savefig("performance_ratio.png", dpi=120)print("Saved performance_ratio.png")Expected output
Application 1: the loss table energy-weighted cell temperature 49.5 deg C, temperature factor 0.914 reference energy 19,874 kWh a year (2,007.5 kWh/m2) stage factor product energy lost here temperature 0.914 0.9140 18,165 1,709 reflection and weak light 0.970 0.8866 17,620 545 module below label, first ageing 0.980 0.8688 17,268 352 soiling 0.970 0.8428 16,750 518 wiring and mismatch 0.970 0.8175 16,247 502 inverter 0.970 0.7930 15,760 487 clipping 0.995 0.7890 15,681 79 availability 0.990 0.7811 15,524 157 performance ratio 0.781; yearly energy 15,524 kWh; lost 4,350 kWh specific yield 1,568 kWh/kWp; capacity factor 17.9 %; mean day 42.5 kWh adding the losses gives 24.1 %, the true loss is 21.9 % without soiling the table gives 0.805; at a performance ratio of 0.75 the year is 14,906 kWh temperature-corrected example: 0.760 at 52 deg C gives 0.839, 0.790 at 44 deg C gives 0.846Application 2: one year of records month days H (kWh/m2) E (kWh) PR rain days Jan 0 to 30 187.8 1432.9 0.771 1 Feb 31 to 58 173.2 1218.7 0.711 0 Mar 59 to 89 178.7 1313.7 0.743 8 Apr 90 to 119 151.5 1203.8 0.803 16 May 120 to 150 143.0 1128.4 0.797 9 Jun 151 to 180 163.1 1242.7 0.769 0 Jul 181 to 211 155.1 1156.3 0.753 2 Aug 212 to 242 151.2 1156.2 0.772 0 Sep 243 to 272 158.5 718.0 0.458 1 Oct 273 to 303 150.3 1175.1 0.789 10 Nov 304 to 333 144.8 1143.9 0.798 15 Dec 334 to 364 176.0 1379.5 0.792 7 year: insolation 1,933.3 kWh/m2 (mean 5.297 a day), energy 14,269 kWh, PR 0.746 specific yield 1,441 kWh/kWp, capacity factor 16.5 %, rain days 69 light against the design mean: -3.7 %; energy against the table: -8.1 % mean of the 12 monthly values 0.746, mean of the 365 daily values 0.748 September, days 243 to 249: PR 0.731; days 250 to 271: PR 0.361 year without days 250 to 271: PR 0.770 February at the table value would give 1,340 kWh; September would give 1,226 kWhSaved performance_ratio.pngCommon Mistakes
- Judging a month by its energy. A cloudy month of a healthy system and a sunny month of a faulty one can give the same kilowatt hours. Divide by the reference energy first.
- Using horizontal or long-term insolation in the performance ratio. The light must be measured in the plane of the array and in the same period as the energy.
- Adding the losses of a table. The factors multiply. For the table of this lesson a sum gives a loss of 24.1 percent where the true loss is 21.9 percent.
- Averaging monthly or daily performance ratios to get the yearly value. Divide the energy of the year by the reference energy of the year.
- Treating the values of a loss table as facts. Each line is an assumption until a data sheet or a measurement replaces it.
- Calling a low performance ratio in a hot month a fault. Heat lowers the value of a healthy system. Compare with the same month of an earlier year, or use a temperature-corrected value.
Summary
- The reference energy
is what a perfect array would give from the light that arrived. The performance ratio is the real energy divided by it. - The performance ratio removes the weather from the reading. Energy, specific yield and capacity factor do not.
- The losses between the light and the meter are written as factors, and the factors multiply. For the site, eight stated factors give a performance ratio of 0.781, a yearly energy of 15,524 kWh at 5.5 peak sun hours, a specific yield of 1,568 kWh/kWp and a capacity factor of 17.9 percent.
- Temperature is the largest loss at a warm site: a factor of 0.914 for the year. A temperature-corrected performance ratio removes it for fair comparison.
- The generated year of the site has a performance ratio of 0.746. The wet months are near 0.80, the dry months fall to 0.711 with dust, and the month with a string fault falls to 0.458.
Exercises
1. An array of 5.0 kWp receives 150 kWh/m² in its plane in one month and gives 580 kWh at the inverter output. Find the performance ratio.
Answer
2. An array of 6.6 kWp gives 9,900 kWh in a year. Find the specific yield and the capacity factor on the array nameplate.
Answer
3. A loss table has the factors 0.90 (temperature), 0.97, 0.96, 0.98 and 0.965. Find the performance ratio, and the yearly energy of an array of 20 kWp with 1,800 kWh/m² a year. What would a sum of the losses have given?
Answer
4. Site A has 12 kWp, received 1,950 kWh/m² and gave 17,500 kWh. Site B has 12 kWp, received 1,700 kWh/m² and gave 16,400 kWh. Which site gave more energy, and which system is in better health?
Answer
Site A gave more energy. Its performance ratio is
5. A month has a performance ratio of 0.740 and an energy-weighted cell temperature of 58 °C. The power coefficient is
Answer
The temperature factor is
6. Use year_of_yield() to find the performance ratio of days 0 to 74 (before the first wet season) and of days 75 to 149 (the first wet season). Explain the difference.
Answer
Days 0 to 74:
References
- G. M. Masters, Renewable and Efficient Electric Power Systems, 2nd edition, Wiley, 2013.
- R. A. Messenger and A. Abtahi, Photovoltaic Systems Engineering, 4th edition, CRC Press, 2017.
- IEC 61724-1, Photovoltaic system performance, Part 1: Monitoring (named here as the standard that defines the performance ratio and how its inputs are measured).
The same 9.9 kWp array gave 1,433 kWh in January and 1,204 kWh in April. The irradiance sensor in the plane of the array measured 187.8 kWh/m² in January and 151.5 kWh/m² in April. In which month did the system itself work better?
The rows are the loss table of Application 1 for the 9.9 kWp array, with the example factors of the lesson. The temperature factor uses the energy-weighted irradiance of 687.5 W/m², NOCT 45 °C and −0.35 percent per °C. Move the air temperature: heat is the largest loss, and the owner cannot remove it. Move the soiling: it is the only large loss the owner controls week by week.
Check yourself
Three questions. Each wrong choice is a mistake people really make, so read the note after you answer.
1. An array of 6 kWp gave 702 kWh in a 30-day month. A sensor in the plane of the array measured 150 kWh/m² in the month. The nearest weather station reports 130 kWh/m² on a horizontal surface. What is the performance ratio of the month?
2. A system has five losses in its chain, and each one is 5 percent. What performance ratio does the loss table give?
3. A hot month has a performance ratio of 0.74 with an energy-weighted cell temperature of 55 °C. A cool month has 0.78 at 43 °C. The power coefficient is −0.35 percent per °C. What do you conclude about the system?
- A perfect array gives its nameplate for each peak sun hour: 9.9 kWp × 5.5 h = 54.5 kWh.
- The performance ratio divides the real energy E by that reference energy.
- Real 42.5 of 54.5 kWh is 0.78. A cloudy day gives 33.9 of 43.4: still 0.78.
- Measure H in the plane of the array, and take E and H over exactly the same period.
Discussion
No comments yet. Questions, results from your own build, a better way to explain it: all welcome.
My notes on this page
Kept on this device only. Nothing is sent anywhere.
Tip: select words in the lesson, or tap a figure or an equation, to put a note right there.
Notes on earlier wording
The lesson has changed and these words are no longer in it. Your notes are kept, with the words you chose.