From millivolts to acceleration
Sensors, Mounting and Measurement Points
On this page
A motor reads 2.1 mm/s in March and 4.4 mm/s in April, a bearing change is ordered, and the old bearing comes out in perfect condition. The machine had not changed: in April a different person held the sensor on the fan cover, not the bearing housing. A reading is only as good as the sensor, its fixing and its place, and a wrong one costs an unnecessary repair or a missed failure. This lesson shows how the common sensors work, how the mounting and the sensor noise limit what they can report, and how to choose and mark measurement points so that this month can be compared with last month. #VibrationSensors #Accelerometer #ConditionMonitoring
Learning Objectives
By the end of this lesson, you will be able to:
- Convert an accelerometer output in millivolts to acceleration and to velocity
- Compare piezoelectric accelerometers, MEMS accelerometers, velocity sensors and proximity probes, with the honest limits of each
- Choose a mounting method that reaches the highest frequency you need
- Calculate the RMS noise of a sensor from its noise density and bandwidth
- Write a measurement point plan with locations, directions and the fault each direction is most sensitive to
Real-World System Problem: One motor, three different readings
The compressor motor of this course (machine A, 22 kW, 1465 rev/min) is measured once a month by three people in turn. One presses a hand-held probe against the motor frame. One puts a magnet on the painted fan cover, because it is the easiest place to reach. One puts the same magnet on the drive-end bearing housing.
The three readings differ by a factor of two or more, and the machine is not the cause. The fan cover is thin sheet that vibrates on its own, like the skin of a drum. A hand-held probe loses the higher frequencies and changes with how hard it is pressed. Only the bearing housing follows the force that the shaft puts into the bearing.
Condition monitoring compares a machine with itself over time, which is valid only if the sensor, the mounting, the place and the direction stay the same.
Fundamental Theory: From the machine surface to a number
The piezoelectric accelerometer
Most industrial vibration measurements use a piezoelectric accelerometer: a small mass resting on a piezoelectric crystal. When the surface accelerates, the mass resists and squeezes the crystal, which gives a charge in proportion to the force. Force is mass times acceleration, so the signal follows the acceleration of the surface.
The common industrial type is called IEPE: it has a small amplifier inside, powered by a constant current of a few milliamperes that the instrument sends along the same two wires that carry the signal.
The sensor is described by its sensitivity
A piezoelectric accelerometer does not respond at 0 Hz. As typical figures, a general-purpose type is useful from about 1 Hz to 10 kHz or more.
MEMS accelerometers, honestly
A MEMS accelerometer is a silicon chip in which a tiny mass on silicon springs moves between fixed plates, changing a capacitance. It costs a small fraction of a piezoelectric sensor, needs little power and responds down to 0 Hz. Two data sheet figures decide what it can do.
Bandwidth. Common low-cost parts are usable from 0 Hz to between a few hundred hertz and a few kilohertz. A few special wide-band parts reach 10 kHz and more.
Noise density. Every sensor adds random noise, given as a noise density
RMS noise of a sensor
A part with
A MEMS sensor is good for trending the overall level against the machine’s own baseline, and for the low and middle frequencies of 1× and 2×, where changes consistent with unbalance or looseness appear.
It stops at early rolling bearing defects: very small signals at several kilohertz, above the bandwidth and below the noise of most low-cost parts. It also stops early when the chip sits on a circuit board in a plastic box, because the board and the box are springs between the machine and the chip. Bearing diagnosis at high frequency needs an industrial accelerometer on a rigid mounting. A MEMS sensor can show that a machine has changed; it is rarely the tool that shows which part of a bearing is damaged.
Velocity sensors
A moving-coil velocity sensor holds a coil on soft springs inside a magnet. The coil stays nearly still in space while the case moves with the machine, and the voltage is proportional to velocity. It needs no power supply and typically works from about 10 Hz to about 1000 Hz, but its moving parts wear. Many sensors sold today as velocity sensors are piezoelectric accelerometers with an integrator inside.
Proximity probes
A proximity probe (eddy current probe) is fixed in the bearing housing and measures, without contact, the gap to the shaft: the shaft’s displacement relative to the housing, in µm. It is the usual sensor for large machines with sleeve bearings, such as turbines, where the shaft moves inside the bearing clearance while the heavy housing hardly moves. The machines of this course have rolling bearings and are measured on the housing with accelerometers.
Mounting: a spring between the machine and the sensor
A sensor on its mounting is a mass on a spring: the sensor is the mass, and the spring is whatever joins it to the machine (a steel stud, adhesive, a magnet, or a hand). Together they have a natural frequency, the mounting resonance
For a mounting with little damping, the reading at a frequency
At one fifth of the mounting resonance the reading is 4 percent high, at one third 12.5 percent high, and at one half 33 percent high. A common working rule is to trust a mounting up to about one third of its resonance.
A stiffer joint gives a higher resonance and a wider usable range. The methods rank as follows.
| Mounting | Typical usable upper frequency | Use |
|---|---|---|
| Stud in a flat, tapped spot face | 10 kHz or more | Permanent sensors, bearing work |
| Adhesive (thin, hard layer or glued pad) | About 5 to 10 kHz | Where drilling is not allowed |
| Flat magnet on a flat, clean pad | About 3 to 7 kHz | Route measurements on prepared points |
| Two-pole magnet on a curved surface | About 2 to 3 kHz | Route measurements on round housings |
| Hand-held probe | About 0.5 to 1 kHz | A quick look only, not for trending |
These figures are typical only. They depend on the mass of the sensor, the flatness and cleanliness of the surface, the thickness of the glue and the strength of the magnet, and the sensor maker’s data for each mounting decides. Paint, rust, dirt or a rocking magnet soften the spring and lower the limit.
Place a magnet by touching one edge to the surface and rolling it down onto the point. A magnet that snaps onto steel gives the sensor a hard shock that can damage it, and it can trap a finger.
Where to measure
The force from the rotor reaches the stationary parts through the bearings, so the sensor goes on the bearing housing, on solid metal with a short, direct path to the bearing. Covers, fan cowls, cooling fins and terminal boxes vibrate on their own and are not acceptable points.
Within the housing, prefer the load zone, the part of the bearing that carries the load: at the bottom on a horizontal machine loaded mainly by its rotor’s weight, and on the side towards the other pulley on a belt drive. The bottom can rarely be reached, so choose the nearest solid point to the load zone that can be reached safely.
Measure in three directions at a bearing where you can.
Horizontal and vertical are the two radial directions. A horizontal machine is usually less stiff horizontally, so a rotating force such as unbalance often shows most in the horizontal reading. Misalignment across a coupling pushes along the shaft and often shows most axially. These are tendencies used as evidence, not proof of a fault.
The same point every time
A change of a few centimetres or a change of direction can alter a reading by more than a developing fault does. Four rules protect the trend.
- Mark the point. A glued steel pad or a tapped hole is best, because it also fixes the direction and gives a clean surface. A painted ring is the minimum. Write the point’s name on the machine and in the record.
- Use the same sensor and the same mounting each time.
- Measure at the same speed and load, and record both with every reading, because vibration changes with both.
- Measure in the same direction. A tilted sensor mixes two directions into one number.
Cable, temperature and earthing
Cable routing. The signal is a few millivolts. A swinging cable pulls on the sensor and adds false low-frequency signal, so clamp it close to the sensor and fix it along its length. Keep it away from motor supply cables and variable speed drive outputs, which radiate strong electrical noise, and never where a moving part can catch it. Use the screened cable the sensor maker specifies.
Temperature limits. A bearing housing can be hot. General-purpose IEPE accelerometers are typically rated to about 120 °C because of the amplifier inside, and many MEMS parts to 85 °C (typical; the data sheet decides). Magnets weaken and adhesives soften when hot, so the mounting has its own limit.
Ground loops. If the sensor case touches the machine frame and the cable screen is also earthed at the instrument, the system is earthed at two places, rarely at the same voltage. A small current flows in the screen and adds a signal at the supply frequency (50 Hz) and its multiples: a serious trap, because 100 Hz is also a real electrical signature of a motor. The cure is designed in before fitting: a sensor with an isolated base or an isolating mounting pad, and a screen earthed at one end only. Any connection to earth, to a panel or to live equipment is work for a qualified electrician.
Application 1: From millivolts to velocity, and what a low-cost sensor would see
Step 1: Acceleration
Click to reveal the acceleration
-
Divide the voltage by the sensitivity.
The component is 0.35 g RMS. ✅
-
Convert to SI units.
The acceleration is 3.43 m/s² RMS. ✅
-
Peak value. For a sine the peak is
g, which is 49.5 mV, about 1 percent of the sensor’s range of 5000 mV. ✅
Step 2: Velocity
Click to reveal the velocity
-
The factor at 100 Hz.
This factor links acceleration and velocity at 100 Hz. ✅
-
Divide the acceleration by it. Work in mm/s², so that the answer is in mm/s.
The velocity is 5.46 mm/s RMS (5.465 to four figures). ✅
-
Check a second way. The Python script makes the 35 mV RMS voltage as samples, converts each sample to acceleration and integrates the samples in time with the trapezium rule, without the formula. It returns 5.464 mm/s RMS. ✅
Step 3: Noise of the two MEMS parts
Click to reveal the noise comparison
-
Part 1, 300 µg/√Hz over 1000 Hz.
The broadband noise of part 1 is 9.49 mg RMS. ✅
-
Part 2, 25 µg/√Hz over 1000 Hz.
The broadband noise of part 2 is 0.79 mg RMS. ✅
-
Against the 100 Hz component. The component is 0.35 g, which is 350 mg RMS.
Even the noisier part sees this component 37 times above its noise. ✅
-
Against the 5 mg bearing signal.
With part 1 the bearing signal is about half of the noise and is lost. With part 2 it is about 6 times the noise. ✅
-
Check with generated noise. The script generates random noise of each density and measures its RMS value: 9.50 mg and 0.79 mg, in agreement with the formula. ✅
Application 2: A measurement point plan for machine A and pump B
Step 1: Name the points
Click to reveal the point names
-
Number along the drive train. Start at the free end of the driver and count towards the driven machine. The name is the machine letter, the bearing number and the direction: A2H is machine A, bearing 2, horizontal. ✅
-
Count the points. Machine A has 3 points and pump B has 4 points, as the drawing below shows. ✅
Step 2: Directions and what each is most sensitive to
Click to reveal the plan
-
Machine A.
Point Bearing housing Direction Most sensitive to A1H Motor NDE Horizontal Unbalance A1V Motor NDE Vertical Looseness, weak base A2H Motor DE Horizontal Unbalance, bearing condition A2V Motor DE Vertical Looseness, bearing condition A2A Motor DE Axial Misalignment A3H Compressor DE Horizontal Unbalance, compressor forces A3V Compressor DE Vertical Looseness, weak base A3A Compressor DE Axial Misalignment Machine A has 8 readings. ✅
-
Pump B.
Point Bearing housing Direction Most sensitive to B1H Motor NDE Horizontal Unbalance B1V Motor NDE Vertical Looseness, weak base B2H Motor DE Horizontal Unbalance, bearing condition B2V Motor DE Vertical Looseness, bearing condition B2A Motor DE Axial Misalignment B3H Pump DE Horizontal Unbalance, vane pass (290 Hz) B3V Pump DE Vertical Looseness, bearing condition B3A Pump DE Axial Misalignment B4H Pump outer end Horizontal Unbalance, vane pass (290 Hz) B4V Pump outer end Vertical Looseness, bearing condition Pump B has 10 readings. ✅
-
Read the last column correctly. It says where a fault usually shows most strongly. A high axial reading is consistent with misalignment, and also with a bent shaft or a bearing set crooked in its housing. ✅
Step 3: Count, time and frequency range
Click to reveal the checks
-
Count from the rule. There are 7 bearings, each with 2 radial readings, and 4 bearings beside a coupling, each with 1 axial reading.
The rule gives 18 readings. ✅
-
Check by the tables. The tables hold
rows. The two counts agree, so no point is missing and none is repeated. ✅ -
Time for the route.
The two machines take about a quarter of an hour. ✅
-
Highest frequency for overall velocity and the pump. Overall velocity is commonly measured to 1000 Hz, and three multiples of the vane pass frequency reach
Hz. A two-pole magnet, typically usable to 2 or 3 kHz, covers both. ✅ -
Highest frequency for bearing work. Bearing defects are searched for near a resonance at several kilohertz, 3200 Hz in this course’s example. That is above the typical limit of a two-pole magnet. The points the plan marks for bearing condition, A2 and B2 to B4, therefore need a glued pad for a flat magnet or a stud, and the maker’s data for the chosen mounting must show a limit above the band used. ✅
Verify It in Python
The script repeats Application 1, integrates the sampled signal as a second check, computes and generates the sensor noise, and prints the reading error below a mounting resonance. Its plot shows how a lower mounting resonance cuts the usable range (the resonance values are examples, not measurements) and how sensor noise grows with bandwidth.
"""Accelerometer output to acceleration and velocity, sensor noise, and the mounting resonance."""import numpy as npimport matplotlib.pyplot as plt
G = 9.81 # m/s^2 in one g
# ---------- Part 1: from millivolts to velocity ----------SENS = 100.0 # mV per gE_RMS = 35.0 # mV RMS, measuredF = 100.0 # Hz
a_g = E_RMS / SENSa_si = a_g * Gv_rms = a_si * 1000.0 / (2.0 * np.pi * F)x_pp = 2.0 * np.sqrt(2.0) * v_rms / (2.0 * np.pi * F) * 1000.0print("Accelerometer, 100 mV/g, 35 mV RMS at 100 Hz")print(f" acceleration: {a_g:.3f} g RMS = {a_si:.4f} m/s^2 RMS, peak {a_g * np.sqrt(2.0):.3f} g")print(f" velocity: {v_rms:.3f} mm/s RMS")print(f" displacement: {x_pp:.2f} um peak-to-peak")
# Second way: make the voltage as samples, convert, and integrate in timefs = 51_200.0t = np.arange(int(fs * 2.0)) / fs # 2 s, 200 whole cyclesvolts_mv = E_RMS * np.sqrt(2.0) * np.sin(2.0 * np.pi * F * t)acc = volts_mv / SENS * G * 1000.0 # mm/s^2vel = np.cumsum((acc[1:] + acc[:-1]) / 2.0) / fs # trapezium rule, mm/svel = vel - vel.mean() # remove the constant of integrationprint(f" integrated from samples: {np.sqrt(np.mean(vel ** 2)):.3f} mm/s RMS")
# ---------- Part 2: sensor noise over a bandwidth ----------SIGNAL_MG = 5.0 # mg RMS, a small bearing signal (assumed)print("RMS noise = noise density x sqrt(bandwidth)")rng = np.random.default_rng(5)cases = (("part 1", 300.0, 1000.0), ("part 2", 25.0, 1000.0), ("part 2, wide band", 25.0, 5000.0))for name, density, band in cases: noise_mg = density * np.sqrt(band) / 1000.0 # ug -> mg fs_n = 2.0 * band # white noise that fills 0 to band sample = rng.normal(0.0, density * np.sqrt(fs_n / 2.0) / 1000.0, 200_000) print(f" {name}: {density:.0f} ug/rtHz over {band:.0f} Hz -> {noise_mg:.2f} mg RMS " f"(generated: {np.sqrt(np.mean(sample ** 2)):.2f}), " f"signal/noise for {SIGNAL_MG:.0f} mg: {SIGNAL_MG / noise_mg:.2f}")big = a_g * 1000.0 / (300.0 * np.sqrt(1000.0) / 1000.0)print(f" the 0.35 g component against part 1: signal/noise {big:.1f}")print(f" part 1 in one 0.25 Hz spectrum line: {300.0 * np.sqrt(0.25):.0f} ug RMS")
# ---------- Part 3: how the mounting resonance limits the frequency ----------print("Reading / true value below a mounting resonance (no damping)")for ratio in (0.2, 1.0 / 3.0, 0.5): print(f" f / f_mount = {ratio:.2f}: {1.0 / (1.0 - ratio ** 2):.3f}")
# ---------- Part 4: the point plan count ----------readings = 7 * 2 + 4 * 1print(f"Point plan: {readings} readings, {readings * 45 / 60:.1f} min at 45 s each")
# ---------- Plot ----------fig, ax = plt.subplots(2, 1, figsize=(8, 7))f = np.logspace(1, 4.3, 600)examples = (("example: stud, 30 kHz", 30_000.0), ("example: flat magnet, 12 kHz", 12_000.0), ("example: two-pole magnet, 6 kHz", 6_000.0), ("example: hand probe, 1.5 kHz", 1_500.0))for label, f_mount in examples: r = f / f_mount zeta = 0.05 # a little damping, to keep the peak finite gain = 1.0 / np.sqrt((1.0 - r ** 2) ** 2 + (2.0 * zeta * r) ** 2) ax[0].loglog(f, gain, label=label)ax[0].axhline(1.125, linewidth=0.8, linestyle="--")ax[0].set_ylim(0.3, 20.0)ax[0].set_xlabel("frequency (Hz)")ax[0].set_ylabel("reading / true value")ax[0].set_title("A weaker mounting lowers the resonance (example values)")ax[0].legend(fontsize=8)band = np.logspace(1, 4, 100)for density in (300.0, 100.0, 25.0): ax[1].loglog(band, density * np.sqrt(band) / 1000.0, label=f"{density:.0f} ug/rtHz")ax[1].axhline(SIGNAL_MG, linewidth=0.8, linestyle="--")ax[1].set_xlabel("bandwidth (Hz)")ax[1].set_ylabel("RMS noise (mg)")ax[1].set_title("Sensor noise against bandwidth, with a 5 mg signal (dashed)")ax[1].legend()fig.tight_layout()fig.savefig("sensor_conversion_noise_mounting.png", dpi=120)print("Saved sensor_conversion_noise_mounting.png")Expected output
Accelerometer, 100 mV/g, 35 mV RMS at 100 Hz acceleration: 0.350 g RMS = 3.4335 m/s^2 RMS, peak 0.495 g velocity: 5.465 mm/s RMS displacement: 24.60 um peak-to-peak integrated from samples: 5.464 mm/s RMSRMS noise = noise density x sqrt(bandwidth) part 1: 300 ug/rtHz over 1000 Hz -> 9.49 mg RMS (generated: 9.50), signal/noise for 5 mg: 0.53 part 2: 25 ug/rtHz over 1000 Hz -> 0.79 mg RMS (generated: 0.79), signal/noise for 5 mg: 6.32 part 2, wide band: 25 ug/rtHz over 5000 Hz -> 1.77 mg RMS (generated: 1.77), signal/noise for 5 mg: 2.83 the 0.35 g component against part 1: signal/noise 36.9 part 1 in one 0.25 Hz spectrum line: 150 ug RMSReading / true value below a mounting resonance (no damping) f / f_mount = 0.20: 1.042 f / f_mount = 0.33: 1.125 f / f_mount = 0.50: 1.333Point plan: 18 readings, 13.5 min at 45 s eachSaved sensor_conversion_noise_mounting.pngCommon Mistakes
- Measuring on a fan cover, a cooling fin or a terminal box because it is easy to reach. Only solid metal with a direct path to the bearing carries the bearing’s vibration.
- Believing the frequency range printed on the sensor while using a magnet or a hand-held probe. The mounting sets the limit, and it is usually far lower.
- Expecting a low-cost MEMS sensor to diagnose a bearing. Check its bandwidth and compute its noise from the noise density before you promise that.
- Reading 50 Hz and 100 Hz lines as machine faults without first asking whether a ground loop or a nearby power cable put them there.
- Treating the “most sensitive” direction as a diagnosis. A high axial reading is consistent with misalignment and with other faults too.
Summary
- A piezoelectric accelerometer gives a voltage in proportion to acceleration. Divide the millivolts by the sensitivity in mV/g to get g, multiply by 9.81 for m/s², and divide by
for the velocity of one component. - A MEMS accelerometer is a good, low-cost tool for trending and for low and middle frequencies. Its bandwidth, its noise (
) and its mounting stop it short of high-frequency bearing work. - The mounting is a spring. Stud mounting reaches the highest frequency, then adhesive, flat magnet, two-pole magnet and hand-held probe, and the maker’s data gives the real limits.
- Measure on the bearing housing, near the load zone, in the horizontal, vertical and axial directions, with the guards in place.
- Mark and name every point, and keep the sensor, mounting, direction, speed and load the same, so that a change in the reading is a change in the machine.
Exercises
1. An accelerometer of 100 mV/g on pump B shows 12 mV RMS at the running frequency of 48.33 Hz. Find the acceleration in g and in m/s² RMS, and the velocity in mm/s RMS.
Answer
2. A MEMS sensor has a noise density of 150 µg/√Hz and is used over a bandwidth of 400 Hz. Find its RMS noise. The 1× component of machine A is 0.0188 g peak. Find the ratio of this component (as RMS) to the noise.
Answer
Noise
3. A sensor on a two-pole magnet has a mounting resonance of 6000 Hz, with little damping. Find the error of the reading at 870 Hz and at 3200 Hz. Find the highest frequency at which the reading is no more than 12.5 percent high.
Answer
At 870 Hz:
4. A condenser fan is driven by a belt. The motor has two bearings and the fan shaft has two bearings. The rule is horizontal and vertical readings at every bearing and one axial reading at the pulley-end bearing of each shaft. Find the number of readings. State where the load zone of the pulley-end bearings lies, and which reading you would add because of it.
Answer
References
- R. B. Randall, Vibration-based Condition Monitoring: Industrial, Automotive and Aerospace Applications, 2nd edition, Wiley, 2021.
- C. Scheffer and P. Girdhar, Practical Machinery Vibration Analysis and Predictive Maintenance, Elsevier, 2004.
- ISO 13373-1:2002, Condition monitoring and diagnostics of machines: Vibration condition monitoring, Part 1: General procedures.
- ISO 5348:2021, Mechanical vibration and shock: Mechanical mounting of accelerometers.
An accelerometer rated to 15 kHz sits on a magnet. The magnet mounting has its own resonance at 9 kHz. You read a component at 4.5 kHz. How good is the reading?
- The surface accelerates. The mass presses on the crystal, which gives a charge in proportion to m × a.
- An amplifier inside (IEPE) takes a constant current; the same two wires carry the signal back.
- The sensitivity sets the scale: 100 mV per g, about 50 g before the 5 V swing is used up.
- A reading of 35 mV RMS is 35 ÷ 100 = 0.35 g, which is 3.43 m/s² RMS.
- At 100 Hz the instrument integrates: 3434 ÷ (2π × 100) = 5.46 mm/s RMS.
The sensor is the mass and the joint is the spring. The surface moves the same amount at every frequency; the block moves by the reading the instrument would show. Each mounting button sets an example resonance, three times the middle of the usable range in the lesson's table: real values depend on the sensor, the surface and the magnet or glue, and the maker's data decides. A little damping is added so the curve stays finite at resonance. The bobbing is slowed down to about one cycle a second so that it can be seen.
Check yourself
Three questions. Each wrong choice is a mistake people really make, so read the note after you answer.
1. A low-frequency accelerometer of 500 mV/g on a slow fan shows one component at 25 Hz with 20 mV RMS. What is its velocity?
2. A MEMS part has a noise density of 100 µg/√Hz. You use it over a band of 4000 Hz to look for an early bearing signal of about 3 mg RMS. Can it see the signal in a broadband reading?
3. A permanent sensor is fitted on a motor with its cable screen earthed at the panel. The next spectra show a new line at 100 Hz and smaller lines at 50 Hz and 150 Hz. The motor itself has not changed. What is the first thing to suspect?
Discussion
No comments yet. Questions, results from your own build, a better way to explain it: all welcome.
My notes on this page
Kept on this device only. Nothing is sent anywhere.
Tip: select words in the lesson, or tap a figure or an equation, to put a note right there.
Notes on earlier wording
The lesson has changed and these words are no longer in it. Your notes are kept, with the words you chose.