Baseline
On this page
A taxi burns more fuel in a week with more trips. To judge a new set of tyres, you do not compare this week's fuel with last week's. You compare it with what the car would have burned on this week's trips. That second number is a baseline: what a site would have used under the same conditions, if nothing had been changed.
See it
A flour mill fits efficient motors in December. In January it uses 16,100 kWh. In January of the year before it used 15,350 kWh. Did the motors save energy?
Each round point is one month of last year. The line through them is the baseline: 4,000 kWh a month when nothing is milled, plus 55 kWh for each tonne. The square is a month after the change. The gap from the line down to the square is the estimated saving. The line is dotted where there are no data.
The idea
A driver is a measured quantity that makes the energy change: tonnes produced, the weather, the number of working days. A baseline is a formula, fitted to a period before the change, that gives the energy for any value of the driver.
With one driver the formula is a straight line. The base load b0 is the energy used when nothing is produced. The slope b1 is the extra energy for each unit of the driver.
x is the driver in the month after the change, here the tonnes produced
The baseline has limits. Last year's points are typically 271 kWh away from the line, so a gap of that size proves nothing. The line is also tested only between 120 t and 300 t, the range of its data.
One worked number
The baseline of a flour mill, fitted to last year, is 4,000 kWh a month plus 55 kWh for each tonne. After new motors are fitted, the mill makes 260 t in a month and the meter reads 16,100 kWh. What is the estimated saving?
Show the worked solution, 3 steps
- Find what the old mill would have used
55 kWh × 260 = 14,300 kWh. Add the base load: 14,300 + 4,000 = 18,300 kWh.
- Take the meter reading away
18,300 − 16,100 = 2,200 kWh. This is the estimated saving.
- Write it as a share and check it
2,200 ÷ 18,300 = 0.120, which is 12.0%. The figure opens on this month.
The mistake to avoid
A second trap is in the words. A meter measures what was used. Nobody can measure what was not used, so call the result an estimated saving and say which baseline it came from.
Check yourself
A bottling plant has a baseline of 2,000 kWh a week plus 0.5 kWh for each crate. After a change it fills 10,000 crates in a week and uses 6,300 kWh. What is the estimated saving?
The electricity bill for March is 8% lower than for March last year. A manager reports that the new lighting saved 8%. What is missing from this claim?
The mill's baseline was fitted to months between 120 t and 300 t. A new contract brings a month of 450 t. Can the same line give the estimated saving for that month?
Where you meet it
- A factoryEnergy is fitted against units produced, so a busy month and a quiet month can be judged by the same rule.
- An office building or a cold roomEnergy is fitted against how hot the days were and how many were working days.
- A borehole pumpEnergy is fitted against the water pumped. A gap that grows above the line is an early sign of wear.
- A baseline is what the site would have used under the same conditions, with no change made.
- It is a formula fitted to past data: a base load plus an amount for each unit of the driver.
- Estimated saving = baseline − meter reading. It is never measured directly.
- The baseline holds only inside the range of its data, and a gap must be larger than the ordinary scatter.
Discussion
No comments yet. Questions, results from your own build, a better way to explain it: all welcome.
My notes on this page
Kept on this device only. Nothing is sent anywhere.
Tip: select words in the lesson, or tap a figure or an equation, to put a note right there.
Notes on earlier wording
The lesson has changed and these words are no longer in it. Your notes are kept, with the words you chose.