One idea Beginner 5 min read
Found this useful?

You can check a kitchen scale with a bag of sugar marked 1 kg. If the scale shows 1.02 kg, you know that it reads 0.02 kg high. Calibration is the same check done with care: an instrument is compared with a better one, called the reference, and the differences are written down.

That it reads right?A sticker has no numbers. Nobody can say how large the error was.Not proved
That it was adjusted?Perhaps. Then the error it had before that day is lost.A different act
That it was compared?Only a sheet of readings against a reference proves that.This is calibration

See it

Predict first

A pressure transmitter has run for two years. A technician sees that it reads a little high, turns the zero screw until it agrees with his test gauge, and writes "calibrated, OK". What has been lost?

See it: five readings against a reference

Largest error now
The same error in bar
Against the ±0.5% tolerance

Each dot is the reading of the transmitter minus the reference, at one of five pressures. The span is the full range, here 10 bar, so 1% of span is 0.1 bar. The dashed line is the correction. The drift here is 0.15% of span a year, the rate this transmitter showed in its records.

The idea

Every instrument has an error: its reading minus the true value. Nobody can see the true value, so you apply a known value from a reference, an instrument that is clearly better. The table of differences is the calibration. Nothing on the instrument is changed.

The table has two uses. It tells you whether the instrument was inside its tolerance, the largest error the site accepts. It also gives a correction: the error with the opposite sign, which you add to each reading.

correction = − error = reference value − reading

add the correction to a reading to remove the known error

A calibration is true on the day it is made. After that the error changes slowly, which is called drift. Past calibrations show how fast, and that rate sets the date of the next one. Drift is not always steady: a knock can move the error in one step.

One worked number

The question

A transmitter with a span of 10 bar has a tolerance of ±0.5% of span. Today's calibration finds its largest error: +0.25% of span, at 0 bar. Its records show a drift of 0.15% of span a year, always upward. It is not adjusted. For how long will it stay inside the tolerance?

Show the worked solution, 3 steps
  1. Put the error in bar

    1% of 10 bar is 0.1 bar, so +0.25% of span is 0.025 bar.

  2. Find the room that is left

    Tolerance minus error = 0.50 − 0.25 = 0.25% of span.

  3. Divide by the drift rate

    0.25 ÷ 0.15 = 1.67 years, which is 20 months. The next calibration must come well before that. Check it in the figure: move the slider to 20 months.

The mistake to avoid

Calibration is not adjustment. Calibration is the comparison and its record. Adjustment is a change to the instrument, such as turning the zero screw. Many calibrations end with no adjustment, and they are still worth doing: the record proves the past readings and adds one point to the drift history. If you adjust, record the errors before and after.

A second trap is the check at one point. A transmitter that is right at zero can still be wrong at the top of its range. The lesson on calibration, drift and traceability uses five points, taken with the pressure rising and then falling.

Check yourself

Question 1

A cold room probe is placed in a stirred mixture of ice and water, which is at 0.0 °C. It shows +0.4 °C. Later, in the room, it shows 5.1 °C. What is the best estimate of the room temperature?

Question 2

A calibration finds a largest error of +0.3% of span on a transmitter with a tolerance of ±0.5%. The technician records ten readings and adjusts nothing. Was the visit wasted?

Question 3

A flow meter had errors of +0.10% after one year and +0.20% after two years, with no adjustment. Its tolerance is ±0.5%. If the drift stays the same, how much longer will it stay inside the tolerance?

Where you meet it

  • A cold room thermometerAn ice and water bath gives 0.0 °C, so the probe can be checked on site between calibrations.
  • A pressure transmitter on a pump lineIf the reading supports a contract, the sheet of errors is the proof that the reading could be trusted.
  • An energy or water meter used for billingThe buyer and the seller both rely on a record that leads back to a national standard.
Key points
  • Calibration is a recorded comparison with a better instrument. It changes nothing.
  • The error is the reading minus the reference. The correction is the error with the opposite sign.
  • Record the errors before any adjustment, or the past readings cannot be judged.
  • Errors drift. The history of past calibrations sets the date of the next one.
Found this useful?