Measurement · Concept

Measurement uncertainty

One idea Intermediate 5 min read
Found this useful?

A builder who says that a wall is 4 m long, give or take 1 cm, has told you more than one who says 4.003 m and nothing else. Every instrument reading needs the same second number. Measurement uncertainty is the stated width of the range in which the true value probably lies.

Yes?4.00 is more than 3.95.Only if the reading is exact
No?The gauge of the client shows 3.9 bar.That gauge has a range too
How sure is 4.00?State the range around the reading, then compare the range with the limit.This is uncertainty

See it

Predict first

A contract requires at least 3.95 bar. The log shows 4.00 bar, and the uncertainty of the measuring chain is 0.08 bar. Does the reading prove that the contract is met?

See it: a reading, its range and a limit

Result (k = 2)
True pressure probably between
Limit of 3.95 bar proved?

The point is the reading and the bar through it is the range in which the true pressure probably lies. The six bars below are the sources of doubt in the chain of the lesson: a pressure transmitter read through a resistor and a converter. The width of the range comes from all six, and mostly from the largest.

The idea

The error of a reading is the reading minus the true value. It is one number with a sign, and it is unknown. The uncertainty is a statement of how large that unknown error could reasonably be. It has no sign, and you can calculate it.

Each source of doubt (the limit of the sensor, its drift, the converter) is first written as a standard uncertainty u: the doubt as one standard deviation. Independent sources rarely reach their worst values together, so they are not added. Their squares are added.

U = k × √(u1² + u2² + …)

U is the expanded uncertainty. k is the coverage factor: with k = 2 the range covers about 95% of cases.

Write the result as 4.00 bar ± 0.08 bar (k = 2). Because the terms are squared, the largest source decides the result, and work on a small one changes nothing.

The rule holds only for independent sources. An error shared by two readings does not combine by squares.

One worked number

The question

A pressure reading has two independent sources of doubt, with standard uncertainties of 0.03 bar and 0.04 bar. The reading is 4.00 bar. State the result with k = 2. Does it prove that the pressure is at least 3.95 bar?

Show the worked solution, 3 steps
  1. Add the squares and take the root

    0.03² + 0.04² = 0.0009 + 0.0016 = 0.0025, and √0.0025 = 0.05 bar. The plain sum, 0.07 bar, would be too large.

  2. Multiply by k

    U = 2 × 0.05 = 0.10 bar. The result is 4.00 bar ± 0.10 bar (k = 2).

  3. Compare the range with the limit

    The range is 3.90 to 4.10 bar. Its lower end is below 3.95 bar, so the limit is not proved. The chain in the figure gives ± 0.08 bar: move the reading up until the whole range is above the limit.

The mistake to avoid

The uncertainty is not the error, and it cannot be subtracted. A result of 4.00 bar ± 0.08 bar does not say that the reading is 0.08 bar wrong. It says that the true value is probably between 3.92 and 4.08 bar. Only a bias that was measured against a reference can be subtracted.

A second trap: a ± with no k cannot be used by the next person, who cannot tell whether it is one standard deviation, two, or a maker's limit.

Check yourself

Question 1

Two independent sources have standard uncertainties of 0.03 bar and 0.04 bar. What is the expanded uncertainty with k = 2?

Question 2

A colleague reads a report that says 4.00 bar ± 0.08 bar (k = 2) and proposes to subtract 0.08 bar from every reading, to be safe. What is wrong with this?

Question 3

A motor took 100 kW before a change and 94 kW after it. Each reading has an uncertainty of ± 3 kW, and the two are independent. What is the uncertainty of the saving of 6 kW?

Where you meet it

  • Energy saving claimsA saving is a difference of two measurements, and it must be larger than its own uncertainty.
  • Contract and quality limitsA pressure, a flow or a product weight proves a limit only when the whole range is beyond it.
  • Cold roomsA reading of 7.8 °C ± 0.5 °C does not show that the room is below a limit of 8 °C.
Key points
  • Every reading is a range. A result is a value, an uncertainty and its k.
  • Independent sources combine by the root of the sum of their squares.
  • The largest source decides the width. Improve that one first.
  • A limit is proved only when the whole range is beyond it.