Skip to content
You Start with one site
Amounts in Start with one site
Electrical Power · Concept

Motor slip

One idea Intermediate 5 min read
Found this useful?

A water wheel in a stream always turns a little slower than the water that drives it. If the wheel moved as fast as the water, the water would not push on it at all. The rotor of an induction motor also turns a little slower than the magnetic field that drives it, and that difference, as a share of the field speed, is the slip.

Lost to friction?Friction is small. A new motor with perfect bearings still shows the gap.Not the reason
A worn motor?The gap is printed on the nameplate of every new motor.Not a fault
The motor needs it?Only a field that passes the rotor bars can drive a current in them.This is slip

See it

Predict first

The field of a motor turns at 1,500 rev/min. Its nameplate gives 1,465 rev/min at full load. Someone measures the running motor at 1,482 rev/min. How heavily is it loaded?

See it: the rotor falls behind the field

Rotor speed
Slip
Power at the shaft

The field always turns at 1,500 rev/min, because the supply frequency sets it. The rotor follows, and the harder the load pulls on the shaft, the further behind it falls. The figure uses the simple rule that the gap is in proportion to the load, which holds between no load and a little above full load.

The idea

The windings of the motor make a magnetic field that rotates. Its speed is the synchronous speed, ns, fixed by the supply frequency and the number of poles. On a 50 Hz supply a 4 pole motor has a field at 1,500 rev/min.

The rotor has no connection to the supply. The field must pass across the rotor bars to drive a current in them, and that current in the field makes the force that turns the shaft. A rotor at exactly the speed of the field would have no current and no torque (turning force). So the rotor runs a little slower.

s = (ns − n) ÷ ns

s is the slip, ns is the synchronous speed and n is the speed of the rotor. Multiply by 100 for percent

A heavier load slows the rotor slightly. The slip rises, the rotor current rises, and the torque rises until it equals the load. In normal running the torque is nearly in proportion to the slip, so the load is about the slip now divided by the slip at full load.

One worked number

The question

A 22 kW motor has a field at 1,500 rev/min and a nameplate speed of 1,465 rev/min. What is its slip at full load? It is measured at 1,482 rev/min. What power does it deliver?

Show the worked solution, 3 steps
  1. Slip at full load

    The rotor is 1,500 − 1,465 = 35 rev/min behind. s = 35 ÷ 1,500 = 0.0233, which is 2.33%. The figure opens on this case.

  2. The gap now, against the gap at full load

    At 1,482 rev/min the rotor is 18 rev/min behind. 18 ÷ 35 = 0.514, so the load is about 51%.

  3. Turn the share into power

    0.514 × 22 kW = 11.3 kW. Check it in the figure: set the load to 51% and read the rotor speed.

The mistake to avoid

Slip is not a loss of speed that a better motor would remove. It is how the motor makes torque. A motor that reads close to 1,500 rev/min is not in perfect health. It is doing almost no work. Read the gap, not the speed.

The estimate is rough: an error of 2 rev/min in the reading is 6% of full load. The supply frequency matters too: at 49.9 Hz the field turns at 1,497 rev/min, not 1,500, and the same 1,482 rev/min means about 43% load. Read the frequency with the speed. The lesson on induction motors, slip and the nameplate shows why the current is a poorer guide.

Check yourself

Question 1

On a 60 Hz supply, a 4 pole motor has a field at 1,800 rev/min and a nameplate speed of 1,760 rev/min. It is measured at 1,775 rev/min. About how heavily is it loaded?

Question 2

A new motor with a field at 1,500 rev/min and a nameplate speed of 1,465 rev/min is measured at 1,497 rev/min. A colleague says it is faulty because it does not run at its nameplate speed. What do you answer?

Question 3

Suppose the rotor of an induction motor could be made to turn at exactly the speed of the field. What torque would the motor give?

Where you meet it

  • A compressor or pump motor in a factoryOne speed reading, taken without contact and with the guards in place, shows which motors are much larger than their load.
  • A replacement motor of a higher efficiency classIt slips less, so it runs a few rev/min faster, and a pump or fan on it takes slightly more power.
  • A variable speed driveThe drive changes the frequency, which moves the speed of the field. The rotor still slips behind it.
Key points
  • The field turns at the synchronous speed. The rotor always turns a little slower.
  • Slip = (field speed − rotor speed) ÷ field speed.
  • Without slip there is no rotor current and no torque.
  • The slip grows with the load, so the gap now divided by the gap at full load estimates the load.
Practice

Found this useful?

Discussion