Skip to content
You Start with one site
Amounts in Start with one site
Vibration & Reliability · Concept

Vibration severity

One idea Beginner 5 min read
Found this useful?

A doctor reads a body temperature against a known range, and the range for a baby differs from the range for an adult. A vibration reading works the same way. Vibration severity is the overall velocity of a machine in mm/s RMS, placed in one of four zones, A to D, whose limits depend on the class of machine.

One meter is wrongPossible, so check peak against RMS and the band.Check this first
Different foundationsA machine on springs moves more and is built for it.Higher limits
Different sizesThe standard groups machines by power or shaft height.Limits by class

See it

Predict first

A 45 kW fan reads 3.54 mm/s RMS. Which zone is it in?

See it: one reading, three classes of machine

Reading used
15 to 300 kW, rigid
15 to 300 kW, flexible

The boundaries are examples commonly quoted from ISO 10816-3:2009, which ISO 20816-3:2022 replaced. The standard for your machine class, and the maker's own limits, decide.

The idea

The overall velocity is the RMS of the vibration velocity on a bearing housing, usually over 10 to 1000 Hz. RMS follows the energy of the whole motion and repeats well between readings. For one sine:

vRMS = vpeak ÷ √2

vpeak the largest velocity in the cycle, in mm/s. √2 = 1.414

Why velocity. Most machines run at 600 to 3600 rev/min, so their vibration lies between 10 and 1000 Hz. Across that range, machines in the same condition show similar velocity, while their displacement and acceleration differ widely. The same 3.54 mm/s RMS is 159 µm of travel at 10 Hz and only 1.6 µm at 1,000 Hz. One velocity limit serves them all.

Why per class. ISO 20816 sorts readings into zones: A for a new machine, B for long service, C for a limited time only, D for a level that may damage the machine. A large machine, or one on a flexible foundation (on springs or a light steel frame), moves more in good health, so its boundaries are higher. In zone C, plan the correction; in zone D, tell the person who can stop the machine that day.

One worked number

The question

A 45 kW fan motor vibrates as one sine at running speed with a peak of 5.0 mm/s. Using the example boundaries, which zone is it in on a rigid foundation, and on a flexible one?

Show the worked solution, 3 steps
  1. Convert to RMS

    5.0 ÷ 1.414 = 3.54 mm/s RMS.

  2. Rigid foundation

    Boundaries 1.4, 2.8 and 4.5 mm/s. 3.54 lies between 2.8 and 4.5: zone C.

  3. Flexible foundation

    Boundaries 2.3, 4.5 and 7.1 mm/s. 3.54 lies between 2.3 and 4.5: zone B. The figure opens on this reading.

The mistake to avoid

One table of limits is not right for every machine. The 1.4, 2.8 and 4.5 mm/s often printed on a workshop wall belong to one class: medium machines on rigid foundations. Find the class and foundation of your machine first.

A second trap: a meter set to peak reads 1.414 times higher than one set to RMS. Press the button in the figure: 3.54 mm/s RMS read as 5.0 moves a rigid machine from zone C to D. Write the quantity, peak or RMS, and the band with every reading.

Check yourself

Question 1

A 30 kW pump on a rigid foundation vibrates as one sine with a peak of 3.0 mm/s. Using the example boundaries 1.4, 2.8 and 4.5 mm/s RMS, which zone is it in?

Question 2

A 500 kW compressor on steel springs reads 4.0 mm/s RMS. A colleague calls it zone C from the chart on the workshop wall (1.4, 2.8, 4.5 mm/s). What should you do first?

Question 3

A motor has read 0.9 mm/s RMS for a year. This month it reads 1.3 mm/s, still zone A. What does this say?

Where you meet it

  • A monthly routeA technician reads each motor and pump at marked points and writes the overall velocity and its zone.
  • Acceptance of a new machineA newly installed machine is expected in zone A. Zone B or worse on day one points to fitting or alignment.
  • A fan on springsIts flexible mounting gives it higher boundaries than the same fan bolted to concrete.
  • A bearing in its early stageIts blows carry so little energy that the overall velocity hardly moves. Zones do not find early bearing damage.
Key points
  • Severity is the overall velocity in mm/s RMS, usually over 10 to 1000 Hz.
  • Velocity is used because one limit fits machines across their usual speeds.
  • Zone boundaries depend on the machine class and foundation. The standard and the maker decide.
  • Peak is 1.414 times RMS. Write the quantity and the band with every reading.
Found this useful?

Discussion

    Comments show your name. Be kind, stay on the topic.