Vibration severity
On this page
A doctor reads a body temperature against a known range, and the range for a baby differs from the range for an adult. A vibration reading works the same way. Vibration severity is the overall velocity of a machine in mm/s RMS, placed in one of four zones, A to D, whose limits depend on the class of machine.
See it
A 45 kW fan reads 3.54 mm/s RMS. Which zone is it in?
The boundaries are examples commonly quoted from ISO 10816-3:2009, which ISO 20816-3:2022 replaced. The standard for your machine class, and the maker's own limits, decide.
The idea
The overall velocity is the RMS of the vibration velocity on a bearing housing, usually over 10 to 1000 Hz. RMS follows the energy of the whole motion and repeats well between readings. For one sine:
vpeak the largest velocity in the cycle, in mm/s. √2 = 1.414
Why velocity. Most machines run at 600 to 3600 rev/min, so their vibration lies between 10 and 1000 Hz. Across that range, machines in the same condition show similar velocity, while their displacement and acceleration differ widely. The same 3.54 mm/s RMS is 159 µm of travel at 10 Hz and only 1.6 µm at 1,000 Hz. One velocity limit serves them all.
Why per class. ISO 20816 sorts readings into zones: A for a new machine, B for long service, C for a limited time only, D for a level that may damage the machine. A large machine, or one on a flexible foundation (on springs or a light steel frame), moves more in good health, so its boundaries are higher. In zone C, plan the correction; in zone D, tell the person who can stop the machine that day.
One worked number
A 45 kW fan motor vibrates as one sine at running speed with a peak of 5.0 mm/s. Using the example boundaries, which zone is it in on a rigid foundation, and on a flexible one?
Show the worked solution, 3 steps
- Convert to RMS
5.0 ÷ 1.414 = 3.54 mm/s RMS.
- Rigid foundation
Boundaries 1.4, 2.8 and 4.5 mm/s. 3.54 lies between 2.8 and 4.5: zone C.
- Flexible foundation
Boundaries 2.3, 4.5 and 7.1 mm/s. 3.54 lies between 2.3 and 4.5: zone B. The figure opens on this reading.
The mistake to avoid
A second trap: a meter set to peak reads 1.414 times higher than one set to RMS. Press the button in the figure: 3.54 mm/s RMS read as 5.0 moves a rigid machine from zone C to D. Write the quantity, peak or RMS, and the band with every reading.
Check yourself
A 30 kW pump on a rigid foundation vibrates as one sine with a peak of 3.0 mm/s. Using the example boundaries 1.4, 2.8 and 4.5 mm/s RMS, which zone is it in?
A 500 kW compressor on steel springs reads 4.0 mm/s RMS. A colleague calls it zone C from the chart on the workshop wall (1.4, 2.8, 4.5 mm/s). What should you do first?
A motor has read 0.9 mm/s RMS for a year. This month it reads 1.3 mm/s, still zone A. What does this say?
Where you meet it
- A monthly routeA technician reads each motor and pump at marked points and writes the overall velocity and its zone.
- Acceptance of a new machineA newly installed machine is expected in zone A. Zone B or worse on day one points to fitting or alignment.
- A fan on springsIts flexible mounting gives it higher boundaries than the same fan bolted to concrete.
- A bearing in its early stageIts blows carry so little energy that the overall velocity hardly moves. Zones do not find early bearing damage.
- Severity is the overall velocity in mm/s RMS, usually over 10 to 1000 Hz.
- Velocity is used because one limit fits machines across their usual speeds.
- Zone boundaries depend on the machine class and foundation. The standard and the maker decide.
- Peak is 1.414 times RMS. Write the quantity and the band with every reading.
Discussion
No comments yet. Questions, results from your own build, a better way to explain it: all welcome.
My notes on this page
Kept on this device only. Nothing is sent anywhere.
Tip: select words in the lesson, or tap a figure or an equation, to put a note right there.
Notes on earlier wording
The lesson has changed and these words are no longer in it. Your notes are kept, with the words you chose.