Every engineering simulation follows the same pattern: write the physics as equations, turn those equations into code, hand them to a numerical solver, and interpret the plots. In this lesson you will learn that pattern by building a battery discharge simulator that predicts the runtime of a lithium cell under a realistic load profile. By the end, you will have a working Python script and a clear understanding of how SciPy’s solve_ivp works. #Simulation #Python #BatteryModeling

What We Are Building

Battery Discharge Simulator

A Python script that models a single lithium-ion cell (3.0 V to 4.2 V range, 3000 mAh capacity). You define a load current profile, and the simulator predicts voltage vs. time, state of charge vs. time, and total runtime before the cell hits its cutoff voltage.

Project specifications:

ParameterValue
Cell ChemistryLithium-ion (single cell)
Nominal Voltage3.7 V
Full Charge Voltage4.2 V
Cutoff Voltage3.0 V
Capacity3000 mAh (3.0 Ah)
Load ProfileVariable (standby + active bursts)
SolverSciPy solve_ivp (RK45)
OutputVoltage vs. time plot, SOC vs. time plot, predicted runtime

The Simulation Workflow



Before we dive into batteries, let’s establish the general pattern that every simulation in this course will follow.

  1. Identify the physics

    What are the governing equations? For a battery, we need the relationship between voltage, state of charge, and current draw.

  2. Write the ODE

    Express the system as a set of first-order ordinary differential equations (ODEs) in the form .

  3. Implement in Python

    Write a function that takes time t and state vector y, and returns the derivative dydt.

  4. Solve with solve_ivp

    Hand your function to SciPy’s solver. Specify initial conditions, time span, and any events (like “stop when voltage hits 3.0 V”).

  5. Plot and interpret

    Visualize the results. Extract engineering quantities (runtime, peak temperature, settling time, etc.).

Setting Up Your Environment



You need Python 3.8 or later with three packages:

Terminal window
pip install numpy scipy matplotlib

Verify the installation:

import numpy as np
import scipy
import matplotlib
print(f"NumPy: {np.__version__}")
print(f"SciPy: {scipy.__version__}")
print(f"Matplotlib: {matplotlib.__version__}")

That is all the software you need for this entire course.

Battery Discharge Physics



The Voltage-SOC Relationship

A lithium-ion cell does not have a constant voltage. As it discharges, the open-circuit voltage (OCV) drops following a characteristic curve that depends on the state of charge (SOC). The SOC is simply the fraction of remaining capacity:

where is the total capacity in ampere-hours and is the discharge current.

As a differential equation:

For the math behind solving ordinary differential equations like this one, see Applied Mathematics: Differential Equations in Real Systems.

This is the ODE we will solve. The current is our input (the load profile), and the SOC is our state variable.

Modeling the Open-Circuit Voltage

Real lithium cells have a voltage curve that is relatively flat in the middle and drops steeply near empty. A common empirical model uses a polynomial fit:

We will use coefficients that approximate a typical 18650 cell:

Voltage vs. SOC (approximate shape)4.2 V3.7 V3.0 V0%50%100%SOC

Internal Resistance

The terminal voltage under load is lower than the OCV due to internal resistance:

For a typical 18650 cell, .

The Load Profile



Instead of a constant current draw, let’s model something realistic: an IoT sensor node that sleeps most of the time and wakes up periodically to take measurements and transmit data.

Current draw over time (repeating pattern)500 mA10 mA0s2s10s12s20sSleep: 10 mA for 8 secondsActive: 500 mA for 2 secondsCycle: 10 secondsAverage: 108 mA

Complete Python Code



Here is the full battery discharge simulator. Save it as battery_simulator.py and run it.

"""
Battery Discharge Simulator
Models a lithium-ion cell under a variable load profile.
Predicts voltage, SOC, and runtime.
"""
import numpy as np
from scipy.integrate import solve_ivp
import matplotlib.pyplot as plt
# -------------------------------------------------------
# Cell parameters
# -------------------------------------------------------
CAPACITY_AH = 3.0 # Cell capacity in Ah
R_INTERNAL = 0.05 # Internal resistance in ohms
V_CUTOFF = 3.0 # Cutoff voltage in V
# OCV polynomial coefficients (fit to a typical 18650 curve)
# V_ocv(SOC) = a0 + a1*SOC + a2*SOC^2 + a3*SOC^3
OCV_COEFFS = [3.0, 0.55, 0.95, -0.30]
def ocv_from_soc(soc):
"""Open-circuit voltage as a function of state of charge."""
a = OCV_COEFFS
soc_clipped = np.clip(soc, 0.0, 1.0)
return a[0] + a[1]*soc_clipped + a[2]*soc_clipped**2 + a[3]*soc_clipped**3
def terminal_voltage(soc, current_a):
"""Terminal voltage under load (OCV minus resistive drop)."""
return ocv_from_soc(soc) - current_a * R_INTERNAL
# -------------------------------------------------------
# Load profile
# -------------------------------------------------------
SLEEP_CURRENT_A = 0.010 # 10 mA during sleep
ACTIVE_CURRENT_A = 0.500 # 500 mA during active burst
ACTIVE_DURATION_S = 2.0 # Active burst lasts 2 seconds
CYCLE_PERIOD_S = 10.0 # One full sleep+active cycle
def load_current(t):
"""
Returns the load current in amperes at time t (seconds).
Repeating pattern: active burst for ACTIVE_DURATION_S,
then sleep for the remainder of the cycle.
"""
phase = t % CYCLE_PERIOD_S
if phase < ACTIVE_DURATION_S:
return ACTIVE_CURRENT_A
else:
return SLEEP_CURRENT_A
# -------------------------------------------------------
# ODE: dSOC/dt = -I(t) / (Q * 3600)
# Note: Q is in Ah, t is in seconds, so we divide by 3600
# -------------------------------------------------------
def battery_ode(t, y):
"""State equation for battery discharge."""
soc = y[0]
current = load_current(t)
dsoc_dt = -current / (CAPACITY_AH * 3600.0)
return [dsoc_dt]
# -------------------------------------------------------
# Event: stop when terminal voltage hits cutoff
# -------------------------------------------------------
def voltage_cutoff_event(t, y):
"""Returns zero when terminal voltage reaches V_CUTOFF."""
soc = y[0]
current = load_current(t)
v_term = terminal_voltage(soc, current)
return v_term - V_CUTOFF
voltage_cutoff_event.terminal = True
voltage_cutoff_event.direction = -1
# -------------------------------------------------------
# Run the simulation
# -------------------------------------------------------
def run_simulation():
"""Simulate battery discharge and plot results."""
soc_initial = 1.0 # Start fully charged
t_max = 200000.0 # Maximum simulation time (seconds)
print("=" * 55)
print(" BATTERY DISCHARGE SIMULATOR")
print("=" * 55)
print(f" Cell capacity: {CAPACITY_AH:.1f} Ah ({CAPACITY_AH*1000:.0f} mAh)")
print(f" Internal resistance: {R_INTERNAL*1000:.0f} mohm")
print(f" Cutoff voltage: {V_CUTOFF:.1f} V")
print(f" Sleep current: {SLEEP_CURRENT_A*1000:.0f} mA")
print(f" Active current: {ACTIVE_CURRENT_A*1000:.0f} mA")
print(f" Duty cycle: {ACTIVE_DURATION_S/CYCLE_PERIOD_S*100:.0f}%")
avg_current = (ACTIVE_CURRENT_A * ACTIVE_DURATION_S +
SLEEP_CURRENT_A * (CYCLE_PERIOD_S - ACTIVE_DURATION_S)) / CYCLE_PERIOD_S
print(f" Average current: {avg_current*1000:.0f} mA")
print("-" * 55)
# Solve the ODE
sol = solve_ivp(
battery_ode,
t_span=[0, t_max],
y0=[soc_initial],
events=voltage_cutoff_event,
max_step=1.0, # Sample at least every 1 second
dense_output=True
)
# Generate smooth time vector for plotting
t_end = sol.t[-1]
t_plot = np.linspace(0, t_end, 2000)
soc_plot = sol.sol(t_plot)[0]
# Compute voltage at each time point
v_plot = np.array([terminal_voltage(s, load_current(t))
for s, t in zip(soc_plot, t_plot)])
# Compute current at each time point (for reference)
i_plot = np.array([load_current(t) for t in t_plot])
# Convert time to hours for plotting
t_hours = t_plot / 3600.0
# Print results
runtime_hours = t_end / 3600.0
final_soc = soc_plot[-1]
print(f" Predicted runtime: {runtime_hours:.1f} hours")
print(f" Final SOC: {final_soc*100:.1f}%")
print(f" Final voltage: {v_plot[-1]:.2f} V")
# Simple estimate for comparison
simple_hours = CAPACITY_AH / avg_current
print(f" Simple estimate: {simple_hours:.1f} hours (capacity / avg current)")
print(f" Difference: {abs(runtime_hours - simple_hours):.1f} hours")
print("=" * 55)
# -------------------------------------------------------
# Plot results
# -------------------------------------------------------
fig, axes = plt.subplots(3, 1, figsize=(10, 8), sharex=True)
fig.suptitle("Battery Discharge Simulation", fontsize=14, fontweight="bold")
# Plot 1: Terminal voltage
axes[0].plot(t_hours, v_plot, color="tab:blue", linewidth=1.5)
axes[0].axhline(y=V_CUTOFF, color="red", linestyle="--", alpha=0.7,
label=f"Cutoff ({V_CUTOFF} V)")
axes[0].set_ylabel("Terminal Voltage (V)")
axes[0].set_ylim([2.8, 4.4])
axes[0].legend(loc="upper right")
axes[0].grid(True, alpha=0.3)
# Plot 2: State of charge
axes[1].plot(t_hours, soc_plot * 100, color="tab:green", linewidth=1.5)
axes[1].set_ylabel("State of Charge (%)")
axes[1].set_ylim([-5, 105])
axes[1].grid(True, alpha=0.3)
# Plot 3: Load current
# Downsample for current plot (it's a square wave)
t_current = np.linspace(0, min(t_end, 60), 1000) # Show first 60 seconds
i_current = np.array([load_current(t) * 1000 for t in t_current])
axes[2].plot(t_current, i_current, color="tab:orange", linewidth=1.0)
axes[2].set_ylabel("Load Current (mA)")
axes[2].set_xlabel("Time (seconds, first 60 s shown)")
axes[2].set_ylim([-50, 600])
axes[2].grid(True, alpha=0.3)
plt.tight_layout()
plt.savefig("battery_discharge.png", dpi=150, bbox_inches="tight")
plt.show()
print("\nPlot saved as battery_discharge.png")
if __name__ == "__main__":
run_simulation()

Running the Simulator



Save the code above and run it:

Terminal window
python battery_simulator.py

You should see output like this:

BATTERY DISCHARGE SIMULATORCell capacity:3.0 Ah (3000 mAh)Internal resistance: 50 mohmCutoff voltage:3.0 VSleep current:10 mAActive current:500 mADuty cycle:20%Average current:108 mAPredicted runtime:26.8 hoursFinal SOC:3.2%Final voltage:3.00 VSimple estimate:27.8 hours (capacity / avg current)Difference:1.0 hours

The simulation predicts about 26.8 hours of runtime, while the naive calculation (capacity divided by average current) gives 27.8 hours. The difference comes from the fact that the simulation accounts for internal resistance losses and the nonlinear voltage curve, which causes the cutoff to trigger before the cell is completely empty.

Understandingsolve_ivp



The core of every simulation in this course is SciPy’s solve_ivp function. Let’s break down how we used it.

The function you pass to solve_ivp must have this signature:

def battery_ode(t, y):
soc = y[0] # Unpack state variables
current = load_current(t) # External input
dsoc_dt = -current / (CAPACITY_AH * 3600.0)
return [dsoc_dt] # Return derivatives

The solver calls this function repeatedly at different time points. Each call returns the rate of change of the state variables. The solver uses these rates to step forward in time.

Key rules:

  • t is a scalar (the current time)
  • y is a 1D array of state variables
  • Return a list or array of the same length as y
  • The function must be deterministic (same inputs produce same outputs)

Experiments to Try



Now that you have a working simulator, change some parameters and see what happens.

Increase Active Current

Change ACTIVE_CURRENT_A to 1.0 (1 A bursts). How much does the runtime drop? Notice that the voltage sags more during active periods because of the higher resistive drop across R_INTERNAL.

Change Duty Cycle

Try ACTIVE_DURATION_S = 1.0 and CYCLE_PERIOD_S = 30.0 (3.3% duty cycle, typical of a real IoT sensor). The runtime should increase dramatically.

Larger Cell

Set CAPACITY_AH = 10.0 to simulate a larger battery pack. The shape of the voltage curve stays the same, but the time axis stretches.

Higher Internal Resistance

Set R_INTERNAL = 0.2 to simulate an aged cell. Watch how the terminal voltage drops faster during active bursts.

Key Takeaways



  1. Every simulation follows the same pattern

    Write the ODE, implement it as a Python function, call solve_ivp, and plot. This pattern works for batteries, circuits, mechanical systems, and control loops.

  2. solve_ivp handles the hard math for you

    You do not need to implement Runge-Kutta or worry about step sizes. The solver adapts its step size automatically to maintain accuracy.

  3. Events give you engineering answers

    Instead of simulating for a fixed time and then searching for the cutoff point, the event mechanism finds the exact moment when a threshold is crossed.

  4. Simple estimates are a useful sanity check

    The naive “capacity / average current” estimate was within 4% of the simulation result. Always compare your simulation to back-of-envelope calculations.

  5. Models are only as good as their inputs

    Our polynomial voltage curve is an approximation. A real battery model would use measured data from the specific cell you are using. The structure of the simulation stays the same; only the coefficients change.

Next Lesson



In the next lesson, we apply this same workflow to electrical circuits. You will simulate RC and RLC circuits, verify time constants, and generate Bode plots that match what you would measure on a real oscilloscope.

Simulating Electrical Circuits →



Comments

Loading comments...
© 2021-2026 SiliconWit®. All rights reserved.
Watch it build: the battery model
1.0 SOC I dSOC/dt = −I ÷ Q 0.05 Ω −0.025 V 4.2 V 3.0 V 0 SOC 1 OCV average 108 mA
  1. The state is one number: the state of charge, 1.0 when the cell is full.
  2. The rule: the SOC falls at I ÷ Q. With Q in seconds, 3.0 Ah is 10,800 A s.
  3. A fitted curve turns the SOC into a voltage: 3.0 V when empty, 4.2 V when full.
  4. The cell's own 0.05 Ω takes 0.025 V off the terminals during a 0.5 A burst.
  5. The input: 500 mA for 2 s in every 10 s, 10 mA between, 108 mA on average.
Predict first

A 3,000 mAh cell feeds a sensor node that draws 108 mA on average: short bursts of 500 mA, and 10 mA between them. The node stops when the cell voltage falls to 3.0 V. Dividing gives 3,000 / 108 = 27.8 hours. What will a simulation that follows every burst predict?

See it: a step that is too long reads the load wrong

Average current the simulation uses
Runtime it predicts
Difference from the 1 s answer

This simulation uses the simplest method. At the start of each step it reads the load current (a point), and it removes that current from the cell for the whole step (the shaded area). The dark line is the real load. The runtime is calculated to the 3.0 V cutoff with the cell of the lesson. Try 2.5 s, 5 s and 10 s.

Check yourself

Three questions. Each wrong choice is a mistake people really make, so read the note after you answer.

1. The node is changed to transmit with more power: bursts of 1 A in place of 0.5 A. The cell is the same (internal resistance 0.05 Ω, cutoff 3.0 V). About how much charge is still in the cell when the node stops?

2. A student writes the rule as dsoc_dt = -current / CAPACITY_AH, with the capacity 3.0 Ah, the average current 0.108 A and the time in seconds. The program runs without an error. What does it report?

3. A data logger draws 200 mA for 1 second at the start of every minute, and 1 mA for the other 59 seconds. A simulation uses a fixed step of 60 seconds and reads the current at the start of each step. What average current does it use?

level state: the level now rule: how fast it falls step: new level, repeat
cutoff 3.0 V at rest in a burst: −0.025 V stops here 4.2% still inside 12% 8% 4% 0% charge left in the cell
Found this useful?