What happened, what it cost, what was saved and what to fix first. Every month, or for the week, the quarter or any period you choose. Give it to your board, your auditor or your financier as it is.
Door left open after loading. The room reached 5.1 °C.
Supervisor called at 18:47. Door closed at 19:01.
20 Oct, 02:00
Power cut, 1 hour 10 minutes. The room stayed below 4 °C.
Generator started by your rule.
2 events. 1 call to the supervisor. The power cut needed nobody.
2What it cost
Item
Amount
KShUSD
Stock lost
0 kg
00
Generator fuel, 1 hour 10 minutes
9 L
1,68013
Total for the month
1,68013
3What was saved
The door was open for 19 minutes, not for a night. No stock was lost. The full temperature record for all 31 days is attached for your auditor.
4What to fix first
Decision
Owner
Cost, KShUSD
Protects
Fit an alarm at the door. It sounds after 3 minutes, where the person is.
Store supervisor
8,00062
12 t of stock
Basis of this record
Limit
4 °C, from your quality plan
Price
Diesel at KSh 180USD 1.38 a litre, generator at 8 litres an hour
Measured
Room temperature, door state, power, and the time of every event
Estimated
Generator fuel used
SiliconWit
Monthly record
Example
SiteBorehole and 24,000 litre tank
Period1 to 31 October 2026
Prepared forOwner, manager, auditor
Pump run dry
2 times
stopped by your rule within 1 minute
At risk each time
KSh300,000USD2,308
one pump, and two weeks without water
Water pumped
426 m³
KSh 18.00USD 0.14 of electricity per m³
Water pumped each day, m³
1What happened
When
Event
Response
9 Oct, 02:10
Motor current fell. The pump was running with no water.
Pump stopped by your rule at 02:11.
9 Oct, 03:25
Water level in the borehole recovered. Pump restarted.
No action needed.
22 Oct, 01:50
The pump ran with no water again, on a full fill.
Pump stopped by your rule at 01:51.
3 events. No calls. Your rule stopped the pump both times.
2What it cost
Item
kWh
KShUSD
Electricity for pumping 426 m³
383
7,66859
Total for the month
383
7,66859
3What was saved
Twice the pump began to run with no water. Your rule stopped it within one minute each time. The tank level looked normal on both nights. At risk each time: one pump, about KSh 300,000USD 2,308.
A pump that runs dry does not fail that day. It loses life each time, and stops on the day you need it most.
4What to fix first
Decision
Owner
Cost, KShUSD
Protects
Lower the pump or slow the fill. The borehole empties faster than it refills on a full fill.
Estate manager
To be quoted
KSh 300,000USD 2,308
Basis of this record
Price
KSh 20USD 0.15 per kWh, from the September electricity bill
Measured
Motor current, tank level, energy used, and the time of every event
Estimated
Cost of a pump replacement, from the last invoice
Adjustments
None this month
SiliconWit
Monthly record
Example
SiteApartment block, 48 units
Period1 to 31 October 2026
Prepared forOwner, manager, auditor
Power cuts covered
14 of 14
generator ran 31 hours
Water pumped
610 m³
pump ran 102 hours
Common area electricity
KSh84,200USD648
4,210 kWh
Generator hours each day, hours
1What happened
When
Event
Response
4 Oct, 19:12
Mains failed for 2 hours 40 minutes.
Generator started in 12 seconds.
17 Oct, 02:00
Corridor lighting found on all night, every night.
Timer corrected by the caretaker on 18 Oct.
2 events. No calls at night.
2What it cost
Item
Amount
KShUSD
Common area electricity
4,210 kWh
84,200648
Generator fuel, 31 hours
372 L
66,960515
Total for the month
151,1601,163
3What was saved
Corridor lighting was on all night. It was found on 17 October and corrected the next day: 38 kWh a night. Saving from November: about KSh 22,800USD 175 a month.
Every power cut, every generator hour and every litre pumped is listed with its time, for the service charge meeting.
4What to fix first
Decision
Owner
Cost, KShUSD
Protects
Service the generator. It reaches 250 hours in about six weeks.
Property manager
35,000269
Cover for every power cut
Basis of this record
Price
KSh 20USD 0.15 per kWh. Diesel at KSh 180USD 1.38 a litre, generator at 12 litres an hour
Measured
Incoming supply, generator hours, pump hours, water, common area energy
Estimated
Generator fuel used, and the saving from November
Adjustments
None this month
SiliconWit
Monthly record
Example
SiteProduction line, 22 kW drive motor
Period1 to 31 October 2026
Prepared forOwner, manager, auditor
Stops from failure
0
the line ran 412 hours
At risk
KSh800,000USD6,154
one motor failure and the stopped line
Vibration at its highest
5.5 mm/s
against a limit of 5.0
Vibration each day, mm/sLimit 5.0 mm/s
1What happened
When
Event
Response
3 Oct, 14:20
Vibration passed the limit you set. It had risen for nine weeks.
Maintenance manager notified at 14:21.
19 Oct, 06:00
Bearing replaced at the planned stop. Two hours.
Closed by the maintenance manager.
20 Oct
Vibration back to its normal level.
No action needed.
3 events. 1 call to the maintenance manager. No stop during production.
2What it cost
Item
Amount
KShUSD
Bearing and labour
1 bearing
18,000138
Total for the month
18,000138
3What was saved
The bearing was replaced at a planned stop, on a day you chose. A failure during production stops the line and often damages the motor. At risk: about KSh 800,000USD 6,154.
Load and temperature stayed normal for all nine weeks. Only the vibration showed it.
4What to fix first
Decision
Owner
Cost, KShUSD
Protects
Check the alignment of the drive. A bearing rarely fails alone.
Maintenance manager
To be quoted
KSh 800,000USD 6,154
Basis of this record
Limit
5.0 mm/s, set by you from the normal level of this motor
Measured
Vibration, motor load, bearing temperature, running hours
Estimated
Cost of a failure, from your last breakdown
Adjustments
None this month
SiliconWit
Monthly record
Example
SitePlant air compressor, 37 kW, 7.5 bar
Period1 to 31 October 2026
Prepared forOwner, manager, auditor
Lost to leaks this month
KSh48,000USD369
2,400 kWh, before the repairs
Saved from now on
KSh90,000USD692
a month, after twelve leaks were fixed
Running with the plant closed
12%
of the time, down from 41%
Energy used with the plant closed, kWhTarget, plant closed
1What happened
When
Event
Response
3 Oct, 02:00
The plant was closed, yet the compressor ran loaded 41% of the night. That is air escaping through leaks.
Maintenance lead told at 08:00 on Monday.
17 Oct, 11:30
Twelve leaks tagged and fixed during the Saturday shutdown. Night running fell to 12%.
Closed by the maintenance lead.
24 Oct, 10:15
Pressure fell to 5.8 bar. The dryer drain had stuck open.
Your rule opened the standby drain; lead called at 10:16.
3 events. 2 calls to the maintenance lead.
2What it cost
Item
kWh
KShUSD
Leaks, 1 to 16 October
2,400
48,000369
Leak repairs, 12 fittings
9,00069
Total for the month
57,000438
3What was saved
Air that leaks out is paid for at the motor. The twelve repairs cut night running from 41% to 12% of the time: 150 kWh a night. Saved from now on: KSh 90,000USD 692 a month.
Over a year that is about KSh 1,095,000USD 8,423.
4What to fix first
Decision
Owner
Cost, KShUSD
Protects
Walk the lines for leaks every quarter. Leaks come back as fittings age.
Maintenance lead
15,000115
KSh 3,000USD 23 a day
Lower the set pressure from 7.5 to 7.0 bar. No machine needs more than 6.5 bar.
Maintenance lead
00
about 4% of compressor energy
Basis of this record
Price
KSh 20USD 0.15 per kWh, from the September bill
Measured
Compressor current, line pressure, run and load hours
Estimated
Leak energy, from the load in the 14 hours a night the plant is closed. Daytime leaks are not counted
Adjustments
Night shift on the 9th excluded
SiliconWit
Monthly record
Example
SiteSteam boiler, 2 tonnes an hour, oil-fired
Period1 to 31 October 2026
Prepared forOwner, manager, auditor
Fuel lost to a failed trap
KSh15,444USD119
140 litres, over 9 days
Boiler trips avoided
1
low water caught before the trip
Condensate returned
84%
target 85%
Condensate returned each day, %Target
1What happened
When
Event
Response
5 Oct, 07:20
Condensate return fell from 85% to 76%. A steam trap on the press line was blowing through.
Maintenance told at 07:30, with the line named.
14 Oct, 15:40
The trap was replaced. Return came back to 84%.
Closed by the maintenance lead.
21 Oct, 05:40
Feed tank level fell to 18%. The duty feed pump had lost its prime.
Your rule started the standby pump. The boiler kept running.
3 events. 2 calls to maintenance. The standby pump needed nobody.
2What it cost
Item
Amount
KShUSD
Steam lost through the trap, 9 days
140 L
15,444119
Steam trap
1
14,000108
Total for the month
29,444226
3What was saved
A trap that blows steam wastes fuel every hour until someone finds it. Left all month, this one would have cost KSh 51,480USD 396. The low feed tank was caught before the boiler tripped and stopped the press line. Kept from waste: KSh 36,036USD 277, and one lost shift.
4What to fix first
Decision
Owner
Cost, KShUSD
Protects
Test every steam trap each quarter. One failed trap cost more than a year of testing.
Maintenance lead
12,00092
KSh 51,480USD 396 a month
Service the duty feed pump. It lost its prime; the next time the standby may also fail.
Boiler operator
35,000269
a boiler trip and a lost shift
Basis of this record
Price
Furnace oil at KSh 110USD 0.85 a litre
Measured
Condensate return, feed tank level, pump current, fuel flow
Estimated
Steam lost, as 3% of fuel while the trap was open
SiliconWit
Monthly record
Example
SiteServer room, two cooling units and a UPS
Period1 to 31 October 2026
Prepared forOwner, manager, auditor
Time above 27 °C
14 min
one event, 9 Oct
Downtime
0 min
servers never slowed
Held below 27 °C
99.97%
of 31 days, recorded throughout
Highest room temperature each day, °CAlarm
1What happened
When
Event
Response
9 Oct, 02:14
Cooling unit 1 stopped. The room reached 29.4 °C.
Your rule started unit 2 at 02:16. On-call engineer called.
10 Oct, 10:30
Unit 1 compressor contactor replaced. Both units ready again.
Closed by the facilities lead.
26 Oct, 09:00
UPS battery test: 11 minutes of backup. 15 are needed.
Replacement ordered by the facilities lead.
3 events. 1 night call. The standby unit started by itself.
2What it cost
Item
Amount
KShUSD
Unit 1 contactor
1
9,50073
Downtime
0 min
00
Total for the month
9,50073
3What was saved
The standby unit was running two minutes after the first one stopped. Without it, a full room like this passes 35 °C in about forty minutes, and the servers slow down or shut off. No downtime this month.
4What to fix first
Decision
Owner
Cost, KShUSD
Protects
Replace the UPS batteries. They give 11 minutes; the generator needs 15 to take the load.
Facilities lead
180,0001,385
the servers through a power cut
Swap the duty unit every week. A unit that never runs is not known to work.
Facilities lead
00
both units ready
Basis of this record
Limit
27 °C, from the equipment makers
Measured
Room temperature, each unit running or stopped, UPS state and battery test
Estimated
Time to 35 °C without cooling
SiliconWit
Monthly record
Example
SiteFlower greenhouse, one hectare
Period1 to 31 October 2026
Prepared forOwner, manager, auditor
Nights above the limit
6
5 handled by your rule, nobody called
Stems lost
0
the longest night above the limit was 40 minutes
Inside the growing range
99.6%
of 31 days and nights
Highest humidity each night, %Limit 90%
1What happened
When
Event
Response
7 Oct, 02:10
Humidity passed 90%. Vents opened and fans ran.
Back in range at 02:40. Nobody was called.
18 Oct, 03:30
Humidity stayed above the limit. One fan did not start.
Farm manager called at 03:45. Fan reset at 04:10.
6 nights above the limit. 1 call to the farm manager.
2What it cost
Item
kWh
KShUSD
Fans and vents, six nights
38
7605.85
Total for the month
38
7605.85
3What was saved
Six nights passed the limit. Your rule handled five with nobody called. On the sixth, a person was called within 15 minutes, not in the morning. At risk on one bad night: about KSh 700,000USD 5,385 of stems.
4What to fix first
Decision
Owner
Cost, KShUSD
Protects
Replace the starter on the bay 3 fan. It failed to start once this month.
Farm manager
4,50035
One bad night
Basis of this record
Limit
90% humidity at night, from your agronomist
Price
KSh 20USD 0.15 per kWh
Measured
Temperature, humidity, vent position, fan state
Estimated
Value of the stems at risk, from your own figure
SiliconWit
Monthly record
Example
SiteDrip irrigation, 4 hectares, borehole fed
Period1 to 31 October 2026
Prepared forOwner, manager, auditor
Water lost
18 m³
one burst, closed in 6 minutes
Water not pumped
310 m³
watered by soil moisture, not the clock
Water used against the plan
91%
the crop got what it needed
Water used each day, m³Plan
1What happened
When
Event
Response
8 Oct, 05:20
Zone 3 flow was 40% above normal. A lateral had burst.
Your rule closed zone 3 at 05:26. Farm manager told.
8 Oct, 09:10
The lateral was repaired. Zone 3 went back on its schedule.
Closed by the farm manager.
19 Oct, 16:00
Rain, 22 mm. Two watering cycles skipped.
Your rule. No action needed.
3 events. 1 call to the farm manager.
2What it cost
Item
Amount
KShUSD
Water lost in the burst
18 m³
1,0808.31
Lateral repair
2,50019
Total for the month
3,58028
3What was saved
The burst was closed in 6 minutes, not found at the evening walk. Watering by soil moisture skipped what the rain and the cool days gave: 310 m³ not pumped. Pumping saved: KSh 18,600USD 143.
4What to fix first
Decision
Owner
Cost, KShUSD
Protects
Replace the zone 3 laterals. They are the oldest on the farm; this is the second burst.
Farm manager
45,000346
a zone left dry, or flooded
Flush the filters every week. A blocked filter shows as a slow fall in flow.
Irrigation hand
00
even watering
Basis of this record
Price
Water at KSh 60USD 0.46 per m³ pumped, from the borehole's energy
Measured
Flow in each zone, soil moisture, rain, pump state
Estimated
Water lost in the burst, and water not pumped against the clock schedule
SiliconWit
Monthly record
Example
SiteDiesel tank, 30,000 litres
Period1 to 31 October 2026
Prepared forOwner, manager, auditor
Lost this month
KSh10,800USD83
60 litres, two events
Loss avoided
KSh136,800USD1,052
leak found on the first night, not at month end
Stock against records
99.7%
18,400 litres issued
Stock difference each day, litres
1What happened
When
Event
Response
11 Oct, 23:40
Level fell 40 litres with nothing issued and the pump off.
Depot manager notified at 23:41.
12 Oct, 08:15
A coupling was leaking. Repaired.
Closed by the depot manager.
24 Oct, 10:05
Delivery of 12,000 litres. The level rose by 11,980 litres.
Noted for the supplier.
3 events. 1 call to the depot manager.
2What it cost
Item
Litres
KShUSD
Leak at the coupling, one night
40
7,20055
Delivery short by 20 litres
20
3,60028
Total for the month
60
10,80083
3What was saved
The drop was on record within one minute. Found at month end it would have run for 20 nights: 800 litres, KSh 144,000USD 1,108. Loss avoided: KSh 136,800USD 1,052.
A level that falls while the pump is off has a cause that can be found. The record does not say who. It says when.
4What to fix first
Decision
Owner
Cost, KShUSD
Protects
Replace both delivery couplings. One has leaked. The other is the same age.
Depot manager
9,00069
KSh 7,200USD 55 a night
Basis of this record
Price
Diesel at KSh 180USD 1.38 a litre
Measured
Tank level and temperature, pump state, every issue and delivery
Estimated
Loss avoided, from the rate of the leak
Adjustments
Level corrected for temperature
SiliconWit
Monthly record
Example
SiteRooftop solar plant, 100 kWp
Period1 to 31 October 2026
Prepared forOwner, manager, auditor
Lost this month
KSh3,400USD26
170 kWh, two events
Loss avoided
KSh23,400USD180
fault repaired in 2 days, not 20
Output against expected
98.6%
11,920 of 12,090 kWh
Energy produced each day, kWhExpected 390 kWh
1What happened
When
Event
Response
12 Oct, 10:40
String 4 stopped producing. Output fell by one sixth.
Site manager notified at 10:41.
14 Oct, 11:15
Fuse replaced. Output returned to normal.
Closed by the site manager.
21 Oct, 13:05
Grid outage, 38 minutes. The plant restarted without a visit.
No action needed.
3 events. 1 call to the site manager.
2What it cost
Item
kWh
KShUSD
String 4 fault, 2 days
130
2,60020
Grid outage, 38 minutes
40
8006.15
Total for the month
170
3,40026
3What was saved
The fault was on record within one minute and repaired in two days. Left until the end of the month it would have run for 20 days: 1,300 kWh, KSh 26,000USD 200. Loss avoided: KSh 23,400USD 180.
Left for a full year, the same fault costs about KSh 474,500USD 3,650.
4What to fix first
Decision
Owner
Cost, KShUSD
Protects
Replace the String 4 fuse holder. A fuse that fails once often fails again.
Site manager
1,50012
KSh 1,300USD 10 a day
Clean the panels. Output on clear days is 3% below August.
Site manager
6,00046
KSh 7,254USD 56 a month
Basis of this record
Expected output
100 kWp × 5 sun hours × 0.78 performance ratio × 31 days
Price
KSh 20USD 0.15 per kWh, from the September electricity bill
Measured
Energy produced, and the time of every event
Estimated
Energy lost in each event, and the loss avoided
Adjustments
None this month
A different record: for learners
Learning engineering with us?
Your record is not a site's month. It is one page that shows the courses and builds you finished, checked, with a QR link an employer can open.