Specific capacity
Borehole Pumps: Drawdown and Yield
On this page
A borehole pump works well for three years. Then, in a long dry season, it starts to trip, the tank is half empty by evening, and one morning the motor has burned. The usual answer is a larger pump, and the larger pump fails faster. The pump was never the limit: the borehole can give only as much water as the ground lets into it, and the water level above the pump shows how near that limit is. This lesson shows how to read that level, how much margin a pump has, and what a falling water table does to the flow and the energy bill. #Boreholes #Drawdown #PumpSystems
Learning Objectives
By the end of this lesson, you will be able to:
- Define static water level, pumping water level, drawdown, specific capacity and submergence
- Calculate the pumping water level and the submergence of a borehole pump at its duty point
- Explain why a pump larger than the yield of the borehole runs dry, and how dry-run protection prevents the damage
- Solve the new duty point when the static water level falls, with its energy for each cubic metre
- Distinguish a falling water table from a worn pump in the records of flow, level and energy
Real-World System Problem: A submersible pump 70 m down a borehole
A site takes 110 m³ of water a day from one borehole. A multistage submersible pump hangs on the rising main with its inlet 70 m below ground. With the pump stopped, the water stands 42 m below ground. When the pump runs, the level falls by several metres and stays there as long as the pump runs.
None of this can be seen from the surface, where the owner sees only a flow at the tank and a bill. So measurement and calculation must answer the two questions that decide the life of the pump: how much water stands above the pump inlet while it runs, and how that changes with the season.
Fundamental Theory: What the borehole can give
Static level, pumping level and drawdown
Water in the ground fills the pores of sand and the cracks of rock. A layer that holds water and lets it move is an aquifer. A borehole is a hole into that layer, and the water in it rises to a level set by the pressure of the water in the ground.
Three levels describe a borehole. All are measured as depth below ground.
- The static water level is the level with the pump stopped for long enough that the level no longer changes.
- The pumping water level is the level while the pump runs at a steady flow.
- The drawdown
is the difference between them.
Drawdown exists for the same reason that a pipe needs head to carry flow: water moves through the ground toward the borehole only if the level in the borehole is lower than the level in the ground round it, and more flow needs a larger difference. The pump does not pull water from the aquifer. It lowers the level in the borehole, and the ground responds, like a bucket that a slow tap refills faster the emptier it is.
Specific capacity
The simplest measure of a borehole is the flow it gives for each metre of drawdown.
A high specific capacity means the ground gives water easily. A low one means each extra m³/h costs many metres of level.
This course takes the drawdown as proportional to the flow,
Why the linear model fails at high flow
A real borehole gives less than the straight line promises, for three reasons.
- Water speeds up as it passes through the screen or the cracks and turns into the borehole. This loss rises roughly with the square of the flow. A common description of a real borehole is
, where the first term is the loss in the aquifer and the second is the loss at the borehole itself. - When the level falls far, part of the water-bearing layer is left dry. In fractured rock, a crack that carried much of the water may now be above the pumping level. Less of the borehole wall gives water, so the drawdown grows faster still.
- Drawdown grows with pumping time. A level that looks steady after one hour can be metres lower after a day, and lower again after a dry month.
So the linear model is safe near the tested flow and unsafe far above it. The only safe guide to what a borehole can give is the pumping test itself: the flow at which the level was held steady for many hours. That flow, with a margin for the dry season, is the safe yield. Choose the pump for the yield of the borehole, never the other way round.
Submergence and what happens when the pump is too large
The submergence is the depth of water above the pump inlet while the pump runs.
The maker of the pump states a minimum submergence. It keeps enough pressure at the inlet to avoid cavitation and to keep air out.
Now suppose the pump is larger than the borehole can supply. It removes water faster than the ground replaces it, and the level cannot settle, because the drawdown this flow needs is more than the depth of water available. Soon the level reaches the inlet: the pump draws air and water, the flow breaks, and the pump runs dry.
Running dry destroys a submersible pump quickly. Its bearings are lubricated by the water passing through them, and its motor is cooled by the water flowing past on the way to the inlet. With no water, the bearings seize and the motor overheats.
A common mistake is to answer a low flow with a larger pump. If the borehole is the limit, a larger pump reaches the inlet level sooner.
Dry-run protection
Dry-run protection stops the pump before the level reaches the inlet. Two methods are common, and many installations use both.
- Level sensing. A probe, or a level transmitter, hangs in the borehole above the pump. When the water falls below a set level, the controller stops the pump.
- Motor underload detection. A pump that has lost its water does little work, so its motor takes less power. The controller watches the motor and stops it when the load falls below a set value. Power is a clearer signal than current for a small motor, because the current of a lightly loaded motor falls only a little.
In both cases the controller waits a set time before it restarts, so that the borehole can recover; without the delay the pump would start and stop many times an hour, which damages the motor. The choice of device, its setting and its wiring belong to a licensed electrician and the pump supplier.
A pump that trips on low level every afternoon takes more than the borehole gives.
Seasons and the duty point
The static water level is not fixed. It falls through a dry season and recovers after rain.
For the pump, a lower static level is a higher lift. Every point of the system curve rises by the same amount, and the shape of the curve does not change.
The duty point moves up the pump curve and to the left: less flow at more head. The pump must run longer for the same daily volume, and each cubic metre is lifted higher, so each costs more energy. The submergence shrinks too, because the level has fallen while the inlet has not moved.
Reading the change in records
A fall of flow has several possible causes, and they need different cures. Three records taken together separate them: the flow, the pumping water level and the energy for each cubic metre.
When the water table falls, the level is lower with the pump stopped and with it running. When the pump wears, the flow falls while the static level is unchanged, and the pumping level even rises a little, because less flow means less drawdown.
Application 1: Specific capacity and submergence
Step 1: Specific capacity
Click to reveal the specific capacity
-
From the pumping test.
The borehole gives 1.5 m³/h for each metre of drawdown. ✅
-
The inverse.
Each extra m³/h lowers the level by 0.667 m, the same value used in the system curve. ✅
Step 2: Level and submergence at the duty point
Click to reveal the pumping water level
-
Drawdown at 12.14 m³/h.
The drawdown is 8.09 m, a little more than in the test because the flow is a little higher. ✅
-
Pumping water level.
While the pump runs, the water stands 50.1 m below ground. ✅
-
Submergence.
There are 19.9 m of water above the inlet. With the pump stopped there are
m. ✅ -
Check a second way. A level transmitter at the inlet depth would read the pressure of 19.91 m of water:
At 10.2 m of water for each bar, 1.95 bar is 19.9 m, which agrees. ✅
Step 3: How far the linear model reaches
Click to reveal the flow that empties the borehole
-
Drawdown that reaches the inlet. The level is at the inlet when the drawdown equals the submergence at rest, 28 m. ✅
-
Flow on the linear model.
The straight line says the level reaches the inlet at 42 m³/h. ✅
-
Can this be trusted? No. The test reached 8.0 m of drawdown, and 28 m is three and a half times as far. Over that range the loss at the borehole grows with the square of the flow, and parts of the water-bearing rock are left above the water. The real level reaches the inlet at a flow well below 42 m³/h. How far below cannot be calculated from one test point. ✅
-
What is safe. The tested flow is 12 m³/h. The duty flow of 12.14 m³/h is 1 percent above it, at the edge of what the test supports. Any plan to take more water needs a new test at the higher flow. ✅
Application 2: The static level falls by 9 m
Step 1: The new duty point
Click to reveal the crossing with the raised system curve
-
Raise the system curve. The lift from the static level to the tank is 9 m more. Only the constant changes:
The drawdown and friction terms stay as they were. ✅
-
Set the pump head equal to the system head.
The duty flow is the positive root. ✅
-
Solve.
The flow has fallen from 12.14 to 10.83 m³/h. ✅
-
Head.
The system curve gives the same:
m. The head has risen by 6.28 m, less than the 9 m fall of level, because the lower flow needs less drawdown and less friction. ✅
Step 2: Power and energy
Click to reveal the electrical input and the energy for each cubic metre
-
Pump efficiency.
The pump is now almost exactly at its best efficiency point. ✅
-
Hydraulic power. With
: The water receives 2.485 kW. ✅
-
Shaft power and electrical input.
The supply gives 4.889 kW, which is 4.5 percent less than the design 5.120 kW. ✅
-
Energy for each cubic metre.
Each cubic metre now costs 0.4514 kWh, 7.0 percent more than the design 0.4217. ✅
-
Running hours.
The pump runs 1.10 hours longer each day than the design 9.06 hours. ✅
-
Yearly energy, if the level stayed low all year.
That is 1,193 kWh more than the design 16,932 kWh, or about 14,300 currency units a year at the example price. ✅
-
Check a second way. The water gains
, which is 0.2295 kWh/m³. The pump and motor together have an efficiency of . Then kWh/m³, the same as step 4. ✅
Step 3: Submergence and the records
Click to reveal what the instruments show
-
Pumping water level.
The pumping level is 8.13 m lower than the design 50.09 m. ✅
-
Submergence.
The water above the inlet has fallen from 19.91 m to 11.78 m. ✅
-
The records of a falling water table.
Record Design Level 9 m lower Change Flow (m³/h) 12.14 10.83 10.8 percent lower Electrical input (kW) 5.120 4.889 4.5 percent lower Energy (kWh/m³) 0.4217 0.4514 7.0 percent higher Running time (h a day) 9.06 10.16 1.10 h longer Level transmitter at 70 m, pump stopped (m of water) 28.0 19.0 9.0 lower Level transmitter at 70 m, pump running (m of water) 19.9 11.8 8.1 lower The flow is lower, the energy for each cubic metre is higher, and the level reading is lower with the pump stopped and with it running. ✅
-
The records of a worn pump. Suppose instead that the static level is still 42 m and the pump has lost 8 percent of its head at every flow. Solving
against the original system curve gives 11.19 m³/h. The pumping water level is m, so the transmitter reads 20.5 m while running, a little more than the design 19.9 m, and still 28.0 m at rest. ✅ -
The difference. In both cases the flow falls and the energy for each cubic metre rises. Only the level separates them. A lower level at rest means the water table. An unchanged level at rest with a lower flow means the pump or the pipe. ✅
Verify It in Python
The script solves the design duty point and the dry-season duty point with a root finder, prints the levels and the energy figures, and adds the worn pump for comparison. It saves one plot of the pump curve with both system curves.
"""Borehole drawdown, submergence and the duty point when the water table falls."""import numpy as npfrom scipy.optimize import brentqimport matplotlib.pyplot as plt
RHO, G = 998.0, 9.81 # water at 20 degCPRICE, DAILY = 12.00, 110.0 # currency units per kWh, m3 per daySTATIC, INLET = 42.0, 70.0 # m below groundC = 8.0 / 12.0 # drawdown, m per m3/h (linear model)ETA_MOTOR = 0.82
def pump(q, wear=1.0): # head factor 1.0 for a new pump return wear * (110.0 - 0.2 * q - 0.2 * q**2)
def system(q, fall=0.0): # valid from 4 to 16 m3/h return 59.65 + fall + 0.8948 * q + 0.05143 * q**2
def eta(q): # typical shape, 4 to 16 m3/h return 0.62 - 0.0045 * (q - 11.0) ** 2
def duty(fall=0.0, wear=1.0): """Solve the duty point and return a dictionary of results.""" q = brentq(lambda x: pump(x, wear) - system(x, fall), 4.0, 16.0) h = pump(q, wear) p_h = RHO * G * (q / 3600.0) * h / 1000.0 p_in = p_h / eta(q) / ETA_MOTOR level = STATIC + fall + C * q return dict(q=q, h=h, eta=eta(q), p_h=p_h, p_shaft=p_h / eta(q), p_in=p_in, sec=p_in / q, hours=DAILY / q, year=p_in / q * DAILY * 365, level=level, subm=INLET - level)
def show(name, d): print(name) print(f" Q = {d['q']:.2f} m3/h, H = {d['h']:.2f} m, pump efficiency {d['eta']:.4f}") print(f" hydraulic {d['p_h']:.3f} kW, shaft {d['p_shaft']:.3f} kW, " f"electrical input {d['p_in']:.3f} kW") print(f" {d['sec']:.4f} kWh/m3, {d['hours']:.2f} h a day, {d['year']:.0f} kWh a year") print(f" drawdown {C * d['q']:.2f} m, pumping water level {d['level']:.2f} m " f"below ground, submergence {d['subm']:.2f} m")
print("Application 1: borehole A")print(f" specific capacity = {12.0 / 8.0:.2f} m3/h per metre of drawdown")print(f" flow that would bring the level to the inlet (linear model) = " f"{(INLET - STATIC) / C:.0f} m3/h")design = duty()show("Design duty point", design)
dry = duty(fall=9.0)show("Application 2: static level 9 m lower", dry)a, b, c = 0.2 + 0.05143, 0.2 + 0.8948, 59.65 + 9.0 - 110.0print(f" check by the quadratic formula: Q = " f"{(-b + np.sqrt(b * b - 4 * a * c)) / (2 * a):.2f} m3/h")print(f" ideal energy {RHO * G * dry['h'] / 3.6e6:.4f} kWh/m3 divided by " f"{dry['eta'] * ETA_MOTOR:.4f} = " f"{RHO * G * dry['h'] / 3.6e6 / (dry['eta'] * ETA_MOTOR):.4f} kWh/m3")print(" change from the design figures:")print(f" flow {100 * (dry['q'] / design['q'] - 1):+.1f} %, " f"input power {100 * (dry['p_in'] / design['p_in'] - 1):+.1f} %, " f"kWh/m3 {100 * (dry['sec'] / design['sec'] - 1):+.1f} %")print(f" hours {dry['hours'] - design['hours']:+.2f} h a day, " f"energy {dry['year'] - design['year']:+.0f} kWh a year, " f"cost {(dry['year'] - design['year']) * PRICE:+.0f} a year")print(f" submergence {design['subm']:.2f} m becomes {dry['subm']:.2f} m")
worn = duty(wear=0.92)print("For comparison: worn pump (8 % less head), static level unchanged")print(f" Q = {worn['q']:.2f} m3/h, pumping water level {worn['level']:.2f} m, " f"submergence {worn['subm']:.2f} m")
# ---------- Plot ----------qq = np.linspace(4.0, 16.0, 100)fig, ax = plt.subplots(figsize=(7, 4.5))ax.plot(qq, pump(qq), label="pump curve")ax.plot(qq, system(qq), label="system curve, wet season")ax.plot(qq, system(qq, 9.0), "--", label="system curve, level 9 m lower")ax.plot([design["q"], dry["q"]], [design["h"], dry["h"]], "o", color="black", label="duty points")ax.set_xlabel("flow (m3/h)")ax.set_ylabel("head (m)")ax.legend()fig.tight_layout()fig.savefig("borehole_drawdown.png", dpi=120)print("Saved borehole_drawdown.png")Expected output
Application 1: borehole A specific capacity = 1.50 m3/h per metre of drawdown flow that would bring the level to the inlet (linear model) = 42 m3/hDesign duty point Q = 12.14 m3/h, H = 78.09 m, pump efficiency 0.6141 hydraulic 2.578 kW, shaft 4.198 kW, electrical input 5.120 kW 0.4217 kWh/m3, 9.06 h a day, 16932 kWh a year drawdown 8.09 m, pumping water level 50.09 m below ground, submergence 19.91 mApplication 2: static level 9 m lower Q = 10.83 m3/h, H = 84.37 m, pump efficiency 0.6199 hydraulic 2.485 kW, shaft 4.009 kW, electrical input 4.889 kW 0.4514 kWh/m3, 10.16 h a day, 18125 kWh a year drawdown 7.22 m, pumping water level 58.22 m below ground, submergence 11.78 m check by the quadratic formula: Q = 10.83 m3/h ideal energy 0.2295 kWh/m3 divided by 0.5083 = 0.4514 kWh/m3 change from the design figures: flow -10.8 %, input power -4.5 %, kWh/m3 +7.0 % hours +1.10 h a day, energy +1193 kWh a year, cost +14313 a year submergence 19.91 m becomes 11.78 mFor comparison: worn pump (8 % less head), static level unchanged Q = 11.19 m3/h, pumping water level 49.46 m, submergence 20.54 mSaved borehole_drawdown.pngIn the plot, the dashed system curve of the dry season lies 9 m above the other at every flow.
Common Mistakes
- Fitting a larger pump because the flow is low. If the borehole is the limit, the larger pump lowers the level to the inlet and runs dry.
- Measuring the static level a few minutes after the pump stops. The level needs time to recover, so a reading taken too soon is too deep.
- Judging the running cost from the input power in kW. In the dry season the kW falls while the energy for each cubic metre rises.
- Blaming the pump for a lower flow without checking the level. A worn pump and a falling water table both reduce the flow, and only the level separates them.
- Treating the dry-run trip as a nuisance and removing it. The trip is the only thing between a low water level and a burned motor.
Summary
- A borehole has a static water level at rest and a lower pumping water level when the pump runs. The difference is the drawdown, and the flow for each metre of drawdown is the specific capacity.
- The borehole of this course has a specific capacity of 1.5 m³/h per metre. At the duty point of 12.14 m³/h the pumping level is 50.1 m below ground, with 19.9 m of water above the inlet.
- The linear drawdown model holds near the tested flow only. Drawdown grows faster at high flow, so the tested yield is the only safe guide, and a pump larger than the yield runs dry unless dry-run protection stops it.
- When the static level falls by 9 m, the duty point moves to 10.83 m³/h at 84.37 m. The energy rises from 0.4217 to 0.4514 kWh/m³, the pump runs 10.16 hours a day, and the submergence falls to 11.8 m.
- A falling water table shows as a lower level at rest. A worn pump shows as a lower flow with the level at rest unchanged.
Exercises
1. A borehole is tested at 9 m³/h and the level settles 6.0 m below the static level. Find the specific capacity and, on the linear model, the drawdown at 15 m³/h.
Answer
2. A vented level transmitter hangs 70 m below ground. With the pump running it reads 150 kPa. The static water level is 42 m below ground. Find the pumping water level and the drawdown.
Answer
3. The static level of the borehole in Application 2 falls by 15 m instead of 9 m. Find the duty point, the energy for each cubic metre, the running hours for 110 m³ and the submergence.
Answer
The system constant becomes 74.65, so
4. A step test on the same borehole gives a better description of the drawdown:
Answer
At 12 m³/h:
5. The maker of the pump in Application 2 asks for a submergence of at least 5 m. Using the linear drawdown model, find how far the static level can fall below 42 m before the submergence at the duty point is 5 m. Give the flow and the running hours at that limit.
Answer
For a fall
References
- F. G. Driscoll, Groundwater and Wells, 2nd edition, Johnson Division, 1986.
- G. P. Kruseman and N. A. de Ridder, Analysis and Evaluation of Pumping Test Data, 2nd edition, ILRI Publication 47, 1990.
- D. K. Todd and L. W. Mays, Groundwater Hydrology, 3rd edition, Wiley, 2005.
- I. J. Karassik, J. P. Messina, P. Cooper and C. C. Heald, Pump Handbook, 4th edition, McGraw-Hill, 2008.
In a long dry season the water in a borehole stands 9 m lower than before. The pump, the pipe and the tank are the same, and the pump's electrical input falls by about 4.5 percent. What happens to the energy used for each cubic metre?
The borehole of the lesson: static level 42 m, pump inlet 70 m, drawdown 0.667 m for each m³/h from the pumping test. A dry-run probe is set 3 m above the inlet. The level settles at the static level plus the drawdown; if that is below the probe, the pump stops, the borehole recovers, and the controller restarts the pump after a delay. The time is drawn faster than a real borehole, and the straight-line drawdown is optimistic far above the tested 12 m³/h: a real borehole reaches the probe at a lower flow.
Check yourself
Three questions. Each wrong choice is a mistake people really make, so read the note after you answer.
1. A pumping test gave a drawdown of 5 m at 10 m³/h. The static water level is 30 m below ground. Taking the drawdown as proportional to the flow, where does the water stand while a pump takes 14 m³/h?
2. In the dry season a borehole pump trips on its low-level probe every afternoon, and the tank is half empty by evening. What is the right response?
3. Compared with last year, a borehole delivers 8 percent less water and uses more energy for each cubic metre. The level transmitter reads the same at rest, and 0.6 m more water above it while the pump runs. What is the most likely cause?
- A borehole into the aquifer. At rest the water stands 42 m below ground.
- With the pump giving 12 m³/h it stands at 50 m: a drawdown of 8 m.
- The lower level in the borehole drives water in from the ground round it.
- Specific capacity: 12 m³/h for 8 m, 1.5 m³/h for each metre.
- In the linear model s = 0.667 Q: 12 m of drawdown at 18 m³/h.
Discussion
No comments yet. Questions, results from your own build, a better way to explain it: all welcome.
My notes on this page
Kept on this device only. Nothing is sent anywhere.
Tip: select words in the lesson, or tap a figure or an equation, to put a note right there.
Notes on earlier wording
The lesson has changed and these words are no longer in it. Your notes are kept, with the words you chose.