The system curve
System Curves: Static and Friction Head
On this page
A pump is ordered for “12 cubic metres an hour at 70 metres”. On site it delivers 10, the tank takes longer to fill, and the supplier and the owner each say the other is at fault. Often neither the pump nor the pipe is faulty. The head that the pipe system asks for was written down as one number, when in truth it changes with every change of flow. This lesson shows how to draw that head as a curve, the system curve, from the levels and the pipe data. You will build the curve for a borehole installation and see how a valve or a blocked filter changes the curve of a booster system. #FluidMechanics #SystemCurve #PumpSystems
Learning Objectives
By the end of this lesson, you will be able to:
- Separate the head a system needs into static head and friction head
- Calculate a system curve point by point, including borehole drawdown
- Fit the points to a formula with a constant, a linear and a squared term, and state the fitting error
- Predict how a part-closed valve, a blocked filter or a change of level moves the curve
- Explain why a system with high static head behaves differently from a system that is all friction
Real-World System Problem: A borehole that feeds a tank on a stand
A submersible pump sits 70 m down a borehole. With the pump stopped, the water in the borehole stands 42 m below the ground. The pump sends water up the borehole and along the ground through 520 m of uPVC pipe with an inside diameter of 63 mm, to the inlet at the top of a tank, 18 m above the ground at the borehole.
Before any water moves, the pump already faces a lift of
So this system needs 60 m at no flow and much more at full flow. A pump can be chosen, or a poor result explained, only when that whole relation is known.
Fundamental Theory: The head a system asks for
What a system curve is
A pump does not decide the flow alone. The pipe system has its own rule: to pass a given flow, it needs a given head. The system curve is the plot of that head against flow,
The rule comes from the energy equation, written from the water surface at the source (point 1) to the place where the water is delivered (point 2). Solved for the pump head, it reads
Here
Sort the terms into two groups: those that do not depend on the flow, and those that do.
Static head
The static head is the part that is there at zero flow. It has two pieces: the difference of height between the two water surfaces, and any difference of pressure between them, written as a head.
For a pump that lifts water from one open tank to another, the pressure term is zero and the static head is only the lift. For a booster pump that must hold a pressure at the taps, that pressure is part of the static head. A pump that cannot produce the static head moves no water at all.
Static head depends on the levels, not on the route. A pipe that climbs over a hill and comes down again has the same static head as a straight one, once it is full and flowing.
Drawdown: static head that grows with flow
A borehole is a special case. When the pump runs, the water level in the borehole falls below the static water level. The fall is the drawdown
For these lessons the drawdown is taken as proportional to the flow:
with
The drawdown is a lift, not a friction loss, but it changes with flow. It gives the system curve a term in
Friction head
The friction and fitting losses in a pipe of length
where
Why friction is not exactly proportional to the square of flow
The bracket is not quite constant, because the friction factor changes with the Reynolds number. In a smooth pipe such as uPVC,
In a rough pipe at high Reynolds number,
Either use
What changes the curve
Two kinds of change are possible, and they look different on the plot.
A change of resistance changes
A change of level or pressure changes
When a pump delivers less than before, ask which of the two has happened. The cure is different in each case.
High static head against all friction
Compare two systems that both need 30 m at 18 m³/h.
- System A is a closed circulation loop, for example chilled water round a building. The water returns to where it started, so the static head is zero:
. - System B lifts water and holds a pressure:
.
At half the flow, 9 m³/h, system A needs
This difference decides how each system responds. System A is like a bicycle on flat ground against the wind; system B is a bicycle going up a hill.
- In system A, a slower pump saves a great amount of energy, because both the flow and the head fall. System B must still be given most of its head at any flow, so the saving is much smaller.
- In system B, the energy to move one cubic metre can never fall below
, however large the pipe. Design can reduce only the friction. - In system B, the curve is flat. A small loss of pump head, from wear or lower speed, causes a large loss of flow, and below the static head the flow stops.
Application 1: The system curve of the borehole installation
Step 1: The terms that do not need the pipe
Click to reveal the static lift and the drawdown
-
Static lift. From the static water level to the tank inlet:
Both ends are at atmospheric pressure, so there is no pressure term. The static lift is 60 m. ✅
-
Drawdown per unit of flow.
Each extra m³/h lowers the pumping water level by 0.667 m. ✅
-
Velocity head at the outlet. The water leaves the pipe with velocity
, so the term stays in the energy equation. The water surface in the borehole hardly moves, so . This one velocity head is the same thing as an exit loss with . Count it once, not twice. ✅ -
The curve to calculate.
The 5.8 is
, and the 1 is the outlet velocity head. ✅
Step 2: Friction at each flow
Click to reveal the four friction calculations
-
Worked point, 12 m³/h. The pipe area is
. Swamee-Jain gives
. ✅ -
Losses at 12 m³/h.
Friction takes 9.41 m, and the fittings with the outlet velocity head take 0.40 m. ✅
-
Repeat for the other flows. Each flow has its own Reynolds number and its own friction factor.
(m³/h) (m/s) Friction (m) Fittings and outlet (m) 4 0.356 22,400 0.02517 1.35 0.04 8 0.713 44,700 0.02138 4.57 0.18 12 1.069 67,100 0.01957 9.41 0.40 16 1.426 89,500 0.01842 15.75 0.70 The friction factor falls by 27 percent from the lowest flow to the highest. ✅
-
Test the square law. From 4 to 16 m³/h the flow rises 4 times. The square law predicts 16 times the friction. The table gives
times. ✅
Step 3: Add the parts
Click to reveal the table of the system curve
-
Total head at each flow.
(m³/h) Static lift (m) Drawdown (m) Friction, fittings, outlet (m) (m) 4 60 2.67 1.39 64.06 8 60 5.33 4.75 70.08 12 60 8.00 9.81 77.81 16 60 10.67 16.46 87.13 The system needs 64.06 m at 4 m³/h and 87.13 m at 16 m³/h. ✅
-
Shares at 12 m³/h. Of the 77.81 m, the static lift is 77.1 percent, the drawdown 10.3 percent, and friction with fittings 12.6 percent. This is a system with high static head. ✅
Step 4: Fit a formula to the points
A formula is easier to use than a table. The form
Click to reveal the fitted curve
-
Least squares. The method chooses
, and so that the sum of the squared differences between the formula and the four points is as small as possible. With four points and three coefficients it is one line of code: numpy.polyfit(Q, H, 2). ✅ -
Coefficients.
To four significant figures,
, and . ✅ -
Fitting error. The formula minus the calculated head at the four flows is
, , and m. The largest fitting error is 0.017 m. Checked at 121 flows between 4 and 16 m³/h, the formula is never more than 0.023 m from the point-by-point value. ✅ -
Read the coefficients with care. The fitted
is 59.65, not the 60 m of static lift. The fitted is 0.8948, more than the 0.667 of the drawdown. The reason is that friction rises as , and the fit shares that curve between its linear and squared terms. The formula describes the total head well. Its separate terms are not exactly the separate physical parts. ✅ -
Check a second way. Put
into the formula: m, against 77.81 m in the table. The Python script below prints the same coefficients and errors. ✅
Application 2: The booster system and a half-closed valve
Step 1: Check the curve with the valve open
Click to reveal the check
-
Head at 18 m³/h.
The curve passes through the design point. ✅
-
Share of static head.
percent. This is also a system with high static head. ✅
Step 2: The head the valve adds
Click to reveal the valve term
-
Pipe area.
The area of the 80 mm pipe is 0.005027 m². ✅
-
Resistance of the valve. With
in m³/h, the velocity is , so The valve adds
metres. ✅ -
New system curve. The static head does not change. The resistances add.
The half-closed valve raises
by 7.6 percent. ✅
Step 3: Compare the two curves
Click to reveal the comparison
-
Head at four flows.
(m³/h) (m/s) Valve adds (m) valve open (m) valve half closed (m) 6 0.332 0.07 22.89 22.96 12 0.663 0.27 25.56 25.83 18 0.995 0.61 30.00 30.61 24 1.326 1.08 36.23 37.30 The two curves start together at 22 m and separate as the flow rises. ✅
-
Check a second way. At 18 m³/h the velocity head is
m. Twelve velocity heads are m, the same as the 0.61 m in the table. ✅ -
A blocked filter for comparison. A filter that is nearly blocked can reach a coefficient of 200 or more. With
on the same pipe, the added head at 18 m³/h is m, and the system would need 40.1 m. ✅
Verify It in Python
The script calculates the borehole system curve point by point, fits the three coefficients, and reports the fitting error. It then adds the valve to the booster curve. It saves one plot with both systems.
"""System curves: the borehole rising main and the booster distribution pipe."""import numpy as npimport matplotlib.pyplot as plt
G, NU = 9.81, 1.004e-6 # m/s2, m2/s (water at 20 degC)
# ---------- Borehole installation ----------STATIC_LIFT = 42.0 + 18.0 # m, static water level to tank inletDRAWDOWN = 8.0 / 12.0 # m per m3/h (tested: 8.0 m at 12 m3/h)D, LENGTH, EPS = 0.063, 520.0, 0.0015e-3K_FITTINGS = 2.0 + 4 * 0.9 + 0.2 # non-return valve, 4 bends, gate valve
def swamee_jain(re, rel): return 0.25 / np.log10(rel / 3.7 + 5.74 / re**0.9) ** 2
def borehole_head(q_m3h): """Return Re, f, drawdown, friction, fittings, exit velocity head, total head.""" v = (q_m3h / 3600.0) / (np.pi * D**2 / 4.0) re = v * D / NU f = swamee_jain(re, EPS / D) hv = v**2 / (2.0 * G) s = DRAWDOWN * q_m3h hf = f * LENGTH / D * hv hm = K_FITTINGS * hv return re, f, s, hf, hm, hv, STATIC_LIFT + s + hf + hm + hv
flows = np.array([4.0, 8.0, 12.0, 16.0])heads = np.array([borehole_head(q)[-1] for q in flows])print("Borehole system curve, point by point")print(" Q Re f drawdown friction fittings exit H")for q in flows: re, f, s, hf, hm, hv, h = borehole_head(q) print(f" {q:4.0f} {re:6.0f} {f:.5f} {s:7.2f} {hf:8.2f} {hm:8.3f} " f"{hv:.3f} {h:6.2f}")
k, b, a = np.polyfit(flows, heads, 2)fit = a + b * flows + k * flows**2print(f"Fit H = a + b Q + k Q^2: a = {a:.4g}, b = {b:.4g}, k = {k:.4g}")print(" fitting error at the four flows (m):", ", ".join(f"{e:+.3f}" for e in fit - heads))print(f" largest fitting error = {np.abs(fit - heads).max():.3f} m")qq = np.linspace(4.0, 16.0, 121)exact = np.array([borehole_head(q)[-1] for q in qq])print(f" largest error anywhere from 4 to 16 m3/h = " f"{np.abs(a + b * qq + k * qq**2 - exact).max():.3f} m")hf4, hf16 = borehole_head(4.0)[3], borehole_head(16.0)[3]print(f" friction rises by a factor {hf16 / hf4:.2f} for 4 times the flow, " f"exponent {np.log(hf16 / hf4) / np.log(4.0):.2f}")h12 = borehole_head(12.0)print(f" at 12 m3/h: static lift {100 * STATIC_LIFT / h12[-1]:.1f} %, " f"drawdown {100 * h12[2] / h12[-1]:.1f} %, " f"friction and fittings {100 * (h12[3] + h12[4] + h12[5]) / h12[-1]:.1f} %")
# ---------- Booster distribution ----------H_STATIC, K_SYS = 22.0, 0.0247 # H = 22 + 0.0247 Q^2D_DIST, K_VALVE = 0.080, 12.0area = np.pi * D_DIST**2 / 4.0k_valve = K_VALVE / (2.0 * G * (area * 3600.0) ** 2) # m per (m3/h)^2print("Booster system curve")print(f" head at 18 m3/h = {H_STATIC + K_SYS * 18.0**2:.2f} m")print(f" valve K = {K_VALVE:.0f} on 80 mm pipe: k_valve = {k_valve:.4g} m per (m3/h)^2")print(f" new curve: H = {H_STATIC:.0f} + {K_SYS + k_valve:.4g} Q^2")for q in (6.0, 12.0, 18.0, 24.0): v = (q / 3600.0) / area print(f" Q = {q:4.0f}: V = {v:.3f} m/s, valve adds {k_valve * q**2:.3f} m, " f"H open = {H_STATIC + K_SYS * q**2:.2f} m, " f"H half closed = {H_STATIC + (K_SYS + k_valve) * q**2:.2f} m")k_filter = 200.0 / (2.0 * G * (area * 3600.0) ** 2)print(f" blocked filter K = 200: adds {k_filter * 18.0**2:.2f} m at 18 m3/h")
# ---------- Plot ----------fig, ax = plt.subplots(1, 2, figsize=(10, 4.5))q_all = np.linspace(0.5, 18.0, 100)ax[0].plot(q_all, [borehole_head(q)[-1] for q in q_all], label="point by point")ax[0].plot(q_all, a + b * q_all + k * q_all**2, "--", label="fitted curve")ax[0].plot(q_all, STATIC_LIFT + DRAWDOWN * q_all, ":", label="static lift and drawdown")ax[0].plot(flows, heads, "o", color="black")ax[0].set_xlabel("flow (m3/h)")ax[0].set_ylabel("head (m)")ax[0].set_title("Borehole system curve")ax[0].legend()q_b = np.linspace(0.0, 26.0, 100)ax[1].plot(q_b, H_STATIC + K_SYS * q_b**2, label="valve open")ax[1].plot(q_b, H_STATIC + (K_SYS + k_valve) * q_b**2, "--", label="valve half closed, K = 12")ax[1].plot(q_b, H_STATIC + (K_SYS + k_filter) * q_b**2, ":", label="blocked filter, K = 200")ax[1].set_xlabel("flow (m3/h)")ax[1].set_ylabel("head (m)")ax[1].set_title("Booster system curve")ax[1].legend()fig.tight_layout()fig.savefig("system_curves.png", dpi=120)print("Saved system_curves.png")Expected output
Borehole system curve, point by point Q Re f drawdown friction fittings exit H 4 22366 0.02517 2.67 1.35 0.038 0.006 64.06 8 44733 0.02138 5.33 4.57 0.150 0.026 70.08 12 67099 0.01957 8.00 9.41 0.338 0.058 77.81 16 89465 0.01842 10.67 15.75 0.601 0.104 87.13Fit H = a + b Q + k Q^2: a = 59.65, b = 0.8948, k = 0.05143 fitting error at the four flows (m): -0.006, +0.017, -0.017, +0.006 largest fitting error = 0.017 m largest error anywhere from 4 to 16 m3/h = 0.023 m friction rises by a factor 11.71 for 4 times the flow, exponent 1.77 at 12 m3/h: static lift 77.1 %, drawdown 10.3 %, friction and fittings 12.6 %Booster system curve head at 18 m3/h = 30.00 m valve K = 12 on 80 mm pipe: k_valve = 0.001868 m per (m3/h)^2 new curve: H = 22 + 0.02657 Q^2 Q = 6: V = 0.332 m/s, valve adds 0.067 m, H open = 22.89 m, H half closed = 22.96 m Q = 12: V = 0.663 m/s, valve adds 0.269 m, H open = 25.56 m, H half closed = 25.83 m Q = 18: V = 0.995 m/s, valve adds 0.605 m, H open = 30.00 m, H half closed = 30.61 m Q = 24: V = 1.326 m/s, valve adds 1.076 m, H open = 36.23 m, H half closed = 37.30 m blocked filter K = 200: adds 10.09 m at 18 m3/hSaved system_curves.pngIn the left plot the fitted curve lies on the calculated points between 4 and 16 m³/h and leaves them slightly below 4 m³/h, which is why the formula carries a range. In the right plot the valve curve is hard to tell from the open curve, and the blocked filter curve is far above both.
Common Mistakes
- Writing the duty of a pump as one flow and one head without the curve behind it. The system needs a different head at every flow.
- Measuring the static lift of a borehole from the ground, or from the pump inlet. The lift starts at the water level, and when the pump runs, at the pumping water level.
- Adding an exit loss of one velocity head and also keeping the outlet velocity head in the energy equation. They are the same head, so count it once.
- Using a resistance
worked out for in m³/s with flows in m³/h, or the reverse. The two values differ by a factor of . - Using a fitted formula outside the flows it was fitted to, or reading its constant term as the exact static head.
- Expecting a part-closed valve to change a system with high static head and low velocity very much. Calculate the velocity head first.
Summary
- The system curve is the head a pipe system needs at each flow. It has a static part, present at zero flow, and a friction part that grows roughly with the square of the flow.
- In a borehole the lift starts at the pumping water level, so drawdown adds a term that grows with the flow.
- Friction in a smooth pipe grows a little more slowly than the square of the flow, because the friction factor falls as the Reynolds number rises.
- For the borehole installation,
between 4 and 16 m³/h, within 0.023 m of the point-by-point calculation. - More resistance makes the curve steeper from the same starting head. A change of level or pressure moves the whole curve up or down.
- A system with high static head needs most of its head at any flow, which limits what a slower pump or a larger pipe can save.
Exercises
1. A system has the curve
Answer
2. A pump lifts water from an open sump to an open tank whose surface is 12 m higher. At 20 m³/h, gauges show that the pump adds a head of 20 m. Assume the square law. Find
Answer
Friction head at 20 m³/h is
3. Use the fitted borehole curve of Application 1 to find the head at 10 m³/h and at 14 m³/h.
Answer
At 10 m³/h:
4. The static water level of the borehole falls by 5 m in a dry season, and the drawdown per unit of flow does not change. Write the new fitted curve and find the head at 12 m³/h.
Answer
Only the constant changes:
5. The valve on the 80 mm distribution pipe of Application 2 is closed further, to
Answer
6. A filter on the 80 mm pipe had a pressure difference of 20 kPa across it at 15 m³/h when clean. Months later the difference is 65 kPa at the same flow. Take
Answer
References
- F. M. White, Fluid Mechanics, 8th edition, McGraw-Hill, 2016.
- Y. A. Çengel and J. M. Cimbala, Fluid Mechanics: Fundamentals and Applications, 4th edition, McGraw-Hill, 2018.
- I. J. Karassik, J. P. Messina, P. Cooper and C. C. Heald, Pump Handbook, 4th edition, McGraw-Hill, 2008.
- Crane Co., Flow of Fluids Through Valves, Fittings and Pipe, Technical Paper No. 410.
A booster system needs 30 m of head at 18 m³/h. Of that, 22 m is the height of the buildings and the pressure the taps need. The flow falls to 9 m³/h, half. About how much head does the system need now?
The curve of the borehole installation, calculated point by point as in Application 1: the static lift of 60 m, the drawdown of 0.667 m for each m³/h, and the friction and fittings of the 63 mm rising main. A fall of the water table lifts every point by the same amount. An added resistance, such as a valve or a dirty filter with loss coefficient K on the same pipe, adds K velocity heads: almost nothing at low flow, a lot at high flow.
Check yourself
Three questions. Each wrong choice is a mistake people really make, so read the note after you answer.
1. A site measures its system curve again after a year. At 4 m³/h the head needed is the same as before. At 16 m³/h it is 10 m higher. What is the most likely cause?
2. A pump lifts water from an open sump to an open tank 10 m higher. At 15 m³/h it adds 19 m of head. Take friction as proportional to the square of the flow. What head does the system need at 30 m³/h?
3. A borehole has a static lift of 60 m from the static water level to the tank inlet. A pumping test gave a drawdown of 8 m at 12 m³/h, taken as proportional to the flow. Leaving friction out, what lift does the pump face at 6 m³/h?
- Static head is there at zero flow: 42 + 18 = 60 m, the same at every flow.
- The borehole level falls as the pump runs: 8 m more lift at 12 m³/h.
- Friction grows with the square of flow: 9.8 m more at 12 m³/h, 77.8 m in all.
- f falls as flow rises, so four times the flow gives 11.7 times the friction, not 16.
Discussion
No comments yet. Questions, results from your own build, a better way to explain it: all welcome.