The duty point
The flow that satisfies this equation, with its head, is the duty point (also called the operating point). The pump and the system choose it together. No setting on the pump chooses it.
The nameplate of a pump says 15 m³/h, and the flow meter on site says 12. The owner thinks the pump is faulty, the supplier says it is not, and the electricity bill is higher than anyone planned. The nameplate gives only one point of a curve, and the pump almost never works at that point. It works where its own curve crosses the curve of the pipe system. This lesson shows how to read a maker’s curve, find that crossing, and calculate the power, the running hours and the energy that follow from it. #PumpCurves #DutyPoint #FluidMechanics
By the end of this lesson, you will be able to:
A site takes 110 m³ of water a day from a borehole. A multistage submersible pump, 70 m down, sends the water up a 63 mm rising main to a tank on a stand. A second pump, a single-stage booster at ground level under the tank, supplies the buildings at a flow that changes through the day.
Each pump was bought from a catalogue page that shows a curve, and each pipe system has its own curve, built from levels and friction. Neither alone says what the flow will be. The flow, the head, the efficiency and the power are all fixed at the one point where the two curves cross.
If that point is far from where the pump was designed to work, the owner pays twice: in electricity every hour, and in bearings, seals and impellers some years later.
A centrifugal pump at a fixed speed does not have one head and one flow, but a relation between them. If the pipe system lets much water through, the pump gives little head; if it resists, the pump gives more head and less flow. The maker measures this relation on a test stand and prints it as the pump curve: head
Two ends of the curve have names.
The pump curve belongs to the pump and its speed. It does not know anything about the pipe.
A full sheet shows four quantities against the same flow axis.
For calculation, a few points read from the head curve are fitted with a quadratic. The borehole pump of this course has three maker’s points, and one quadratic passes through all of them. The efficiency formulas used here have a typical shape, a peak with a fall on both sides. Use the maker’s own efficiency curve when you have it.
The system curve is the head the pipes need at each flow. The pump curve is the head the pump gives at each flow. Steady running is possible only where the two are equal.
The duty point
The flow that satisfies this equation, with its head, is the duty point (also called the operating point). The pump and the system choose it together. No setting on the pump chooses it.
The crossing is stable. At a flow a little above it, the system needs more head than the pump gives, so the water slows down. A little below it, the pump gives more head than the system needs, so the water speeds up. Either way the flow returns to the crossing, as a ball rolls back to the bottom of a bowl.
When both curves are quadratics, the equation is a quadratic in scipy.optimize.brentq, which needs only a function and two flows that bracket the crossing.
A common mistake is to read the duty flow from the pump curve at the “design head” written on the order. The order does not choose the duty point: the curves cross where the levels and valves of that day put them.
Once
Power at the duty point
The motor rating on a nameplate is shaft power, so compare it with
The number that follows a pumping system through its life is the specific energy, the electrical energy used for each cubic metre:
The flow at which the efficiency peaks is the best efficiency point, or BEP. The impeller blades and the casing are shaped for the water angles and velocities of that one flow. At the BEP the water enters the blades smoothly, leaves them smoothly, and the pressure round the impeller is even.
Away from the BEP the pump still works, but two things get worse together: more of the shaft power becomes heat and turbulence, so each cubic metre costs more energy, and the forces inside the pump grow, so bearings, seals and wear rings live shorter.
A common guide is to keep a pump between about 70 and 120 percent of its BEP flow for continuous running. The maker’s stated range, when given, replaces this guide.
Far to the left, near shut-off, the pump delivers little water but still takes a large share of its power, and that power can only heat the water inside the casing. At true shut-off all of it becomes heat: a pump left running against a closed valve can boil the water it holds. The flow inside the impeller also breaks down and turns back at the inlet and outlet (recirculation), causing noise, vibration and wear. In a single-volute pump such as the booster, the pressure round the impeller becomes uneven at low flow and pushes the shaft sideways. This radial load bends the shaft a little at every turn and loads the bearings and the seal.
Far to the right, near run-out, the inlet velocity is high and the NPSH required rises steeply. If the system cannot supply that margin, vapour bubbles form and collapse on the impeller: cavitation. The shaft power of a radial pump is also highest here, so a motor sized for the middle of the curve can be overloaded. Pumps reach this region when the system resistance is much lower than expected, for example a burst main or a pump that discharges into an empty pipe.
At zero flow.
At 10 m³/h.
The formula gives the maker’s 88 m. ✅
At 15 m³/h.
The formula gives the maker’s 62 m, so it passes through all three points. ✅
Set the pump head equal to the system head.
Collect the terms on one side:
The duty flow is the positive root of this quadratic. ✅
Solve.
The duty flow is 12.14 m³/h, inside the range of the system curve. ✅
Head at the duty point. From the pump curve:
The system curve gives the same:
Pump efficiency.
The pump runs at 61.4 percent, at 110 percent of its BEP flow. ✅
Convert the flow.
The flow is 3.37 litres per second. ✅
Hydraulic power.
The water receives 2.58 kW. ✅
Shaft power.
The pump shaft takes 4.20 kW. ✅
Electrical input. There is no drive, so only the motor efficiency applies.
The supply gives 5.12 kW. ✅
Is the 5.5 kW motor adequate? The rating is shaft power. The pump needs 4.20 kW, which is 76 percent of 5.5 kW. Over the whole range from 4 to 16 m³/h, the largest shaft power is 4.77 kW, at 16 m³/h. The motor is adequate at the duty point and is not overloaded anywhere in the range. ✅
Specific energy.
Each cubic metre costs 0.422 kWh of electricity. ✅
Running hours.
The pump must run for 9.06 hours to deliver the daily demand. ✅
Daily energy and cost.
The borehole pump uses 46.39 kWh a day. ✅
Yearly energy and cost.
The pump costs about
Check a second way. The wire-to-water efficiency is
Equal heads.
With every valve open the pump settles at 23.34 m³/h. ✅
Head and efficiency there.
The natural duty point is 23.34 m³/h at 35.46 m, at 130 percent of the BEP flow. ✅
Power.
The pump takes 3.96 kW from the supply at its natural duty point. ✅
What the pump gives and what the system needs.
At 18 m³/h the pump gives 8.1 m more than the system needs. ✅
Where the surplus goes. To hold 18 m³/h at full speed, a valve must take the 8.1 m. That is 21 percent of the pump head, turned into heat and noise in the valve. In hydraulic power it is
Power at 18 m³/h, throttled. The efficiency is at its peak, 0.68.
The other way. A slower pump has a lower curve. At the right speed the curve passes through 18 m³/h at 30.0 m with the valve open, and nothing is thrown away. That is the subject of the next lesson. ✅
Points on the pump curve at full speed.
| Pump head (m) | System needs (m) | kWh/m³ | ||||
|---|---|---|---|---|---|---|
| 6 | 41.57 | 22.89 | 0.507 | 1.34 | 1.52 | 0.253 |
| 18 | 38.11 | 30.00 | 0.680 | 2.74 | 3.12 | 0.173 |
| 24 | 35.09 | 36.23 | 0.637 | 3.60 | 4.09 | 0.170 |
The electrical input is 1.52 kW at 6 m³/h and 4.09 kW at 24 m³/h. ✅
The low end. At 6 m³/h the pump is at one third of its BEP flow. It gives 41.57 m, the system needs 22.89 m, and the valve takes 18.68 m, which is 45 percent of the pump head. Each cubic metre costs 0.253 kWh, about one and a half times the cost at 18 m³/h. ✅
The high end. At 24 m³/h the pump gives 35.09 m but the system curve asks for 36.23 m. The pump is 1.14 m short. On this system curve it cannot reach 24 m³/h at full speed: it stops at the natural duty point, 23.34 m³/h. The row for 24 m³/h describes the pump only if the system resistance is a little lower than the curve says. ✅
Check with the script. The Python script solves the natural duty point with a root finder and prints the same table. ✅
The script checks the fitted pump curve against the maker’s points, solves both duty points with a root finder, and prints the powers, the energy and the cost. It saves one plot with both pumps.
"""Duty points: borehole pump on its system curve, and the booster pump."""import numpy as npfrom scipy.optimize import brentqimport matplotlib.pyplot as plt
RHO, G = 998.0, 9.81 # water at 20 degCPRICE, DAILY = 12.00, 110.0 # currency units per kWh, m3 per day
def power(q_m3h, head, eta_pump, eta_motor): """Return hydraulic, shaft and electrical input power in kW.""" p_h = RHO * G * (q_m3h / 3600.0) * head / 1000.0 p_shaft = p_h / eta_pump return p_h, p_shaft, p_shaft / eta_motor
# ---------- Borehole pump (fixed speed, 2900 rev/min) ----------def pump_c(q): return 110.0 - 0.2 * q - 0.2 * q**2
def system_c(q): # valid from 4 to 16 m3/h return 59.65 + 0.8948 * q + 0.05143 * q**2
def eta_c(q): # typical shape, 4 to 16 m3/h return 0.62 - 0.0045 * (q - 11.0) ** 2
ETA_MOTOR_C, RATING_C = 0.82, 5.5
print("Maker's points against the fitted pump curve")for q, h in ((0.0, 110.0), (10.0, 88.0), (15.0, 62.0)): print(f" Q = {q:4.0f}: maker {h:6.1f} m, formula {pump_c(q):6.2f} m, " f"difference {pump_c(q) - h:+.2f} m")
q_d = brentq(lambda q: pump_c(q) - system_c(q), 4.0, 16.0)h_d = pump_c(q_d)p_h, p_s, p_in = power(q_d, h_d, eta_c(q_d), ETA_MOTOR_C)sec = p_in / q_dhours = DAILY / q_dprint("Application 1: borehole duty point")print(f" Q = {q_d:.2f} m3/h, H = {h_d:.2f} m (system curve gives {system_c(q_d):.2f} m)")print(f" pump efficiency = {eta_c(q_d):.4f}")print(f" hydraulic {p_h:.3f} kW, shaft {p_s:.3f} kW, electrical input {p_in:.3f} kW")print(f" shaft power is {100 * p_s / RATING_C:.0f} % of the {RATING_C} kW rating")qq = np.linspace(4.0, 16.0, 241)p_all = np.array([power(q, pump_c(q), eta_c(q), ETA_MOTOR_C)[1] for q in qq])print(f" largest shaft power from 4 to 16 m3/h = {p_all.max():.2f} kW " f"at {qq[p_all.argmax()]:.0f} m3/h")print(f" wire-to-water efficiency = {eta_c(q_d) * ETA_MOTOR_C:.3f}")print(f" specific energy = {sec:.4f} kWh/m3")print(f" running time for {DAILY:.0f} m3 = {hours:.2f} h a day")print(f" energy = {sec * DAILY:.2f} kWh a day, {sec * DAILY * 365:.0f} kWh a year")print(f" cost = {sec * DAILY * PRICE:.0f} a day, {sec * DAILY * 365 * PRICE:.0f} a year")a, b, c = 0.2 + 0.05143, 0.2 + 0.8948, 59.65 - 110.0print(f" check by the quadratic formula: Q = " f"{(-b + np.sqrt(b * b - 4 * a * c)) / (2 * a):.2f} m3/h")
# ---------- Booster pump (fixed speed, no drive) ----------def pump_e(q): return 42.0 - 0.012 * q**2
def system_e(q): return 22.0 + 0.0247 * q**2
def eta_e(q): return 0.68 - 0.0012 * (q - 18.0) ** 2
ETA_MOTOR_E = 0.88q_n = brentq(lambda q: pump_e(q) - system_e(q), 1.0, 40.0)p_h, p_s, p_in = power(q_n, pump_e(q_n), eta_e(q_n), ETA_MOTOR_E)print("Application 2: booster at full speed")print(f" natural duty point: Q = {q_n:.2f} m3/h, H = {pump_e(q_n):.2f} m, " f"efficiency {eta_e(q_n):.4f}, shaft {p_s:.3f} kW, input {p_in:.3f} kW")for q in (6.0, 18.0, 24.0): p_h, p_s, p_in = power(q, pump_e(q), eta_e(q), ETA_MOTOR_E) print(f" Q = {q:4.0f}: pump {pump_e(q):.2f} m, system {system_e(q):.2f} m, " f"surplus {pump_e(q) - system_e(q):+.2f} m, efficiency {eta_e(q):.4f}, " f"shaft {p_s:.3f} kW, input {p_in:.3f} kW, {p_in / q:.3f} kWh/m3")p_valve = RHO * G * (18.0 / 3600.0) * (pump_e(18.0) - system_e(18.0)) / 1000.0print(f" at 18 m3/h the valve destroys {p_valve:.3f} kW of hydraulic power, " f"{100 * (pump_e(18.0) - system_e(18.0)) / pump_e(18.0):.1f} % of the pump head")
# ---------- Plot ----------fig, ax = plt.subplots(1, 2, figsize=(10, 4.5))q1 = np.linspace(4.0, 16.0, 100)ax[0].plot(q1, pump_c(q1), label="pump curve")ax[0].plot(q1, system_c(q1), label="system curve")ax[0].plot(q_d, h_d, "o", color="black", label="duty point")ax[0].set_title("Borehole pump")q2 = np.linspace(0.0, 28.0, 100)ax[1].plot(q2, pump_e(q2), label="pump curve")ax[1].plot(q2, system_e(q2), label="system curve")ax[1].plot(q_n, pump_e(q_n), "o", color="black", label="natural duty point")ax[1].plot([18.0, 18.0], [system_e(18.0), pump_e(18.0)], "k:", label="head lost in the valve")ax[1].set_title("Booster pump")for axis in ax: axis.set_xlabel("flow (m3/h)") axis.set_ylabel("head (m)") axis.legend()fig.tight_layout()fig.savefig("duty_point.png", dpi=120)print("Saved duty_point.png")Expected output
Maker's points against the fitted pump curve Q = 0: maker 110.0 m, formula 110.00 m, difference +0.00 m Q = 10: maker 88.0 m, formula 88.00 m, difference +0.00 m Q = 15: maker 62.0 m, formula 62.00 m, difference +0.00 mApplication 1: borehole duty point Q = 12.14 m3/h, H = 78.09 m (system curve gives 78.09 m) pump efficiency = 0.6141 hydraulic 2.578 kW, shaft 4.198 kW, electrical input 5.120 kW shaft power is 76 % of the 5.5 kW rating largest shaft power from 4 to 16 m3/h = 4.77 kW at 16 m3/h wire-to-water efficiency = 0.504 specific energy = 0.4217 kWh/m3 running time for 110 m3 = 9.06 h a day energy = 46.39 kWh a day, 16932 kWh a year cost = 557 a day, 203186 a year check by the quadratic formula: Q = 12.14 m3/hApplication 2: booster at full speed natural duty point: Q = 23.34 m3/h, H = 35.46 m, efficiency 0.6457, shaft 3.486 kW, input 3.962 kW Q = 6: pump 41.57 m, system 22.89 m, surplus +18.68 m, efficiency 0.5072, shaft 1.337 kW, input 1.520 kW, 0.253 kWh/m3 Q = 18: pump 38.11 m, system 30.00 m, surplus +8.11 m, efficiency 0.6800, shaft 2.744 kW, input 3.118 kW, 0.173 kWh/m3 Q = 24: pump 35.09 m, system 36.23 m, surplus -1.14 m, efficiency 0.6368, shaft 3.596 kW, input 4.087 kW, 0.170 kWh/m3 at 18 m3/h the valve destroys 0.397 kW of hydraulic power, 21.3 % of the pump headSaved duty_point.pngThe script carries all digits, so its yearly cost is
1. A pump has the curve
2. The borehole pump of Application 1 is tested at 10 m³/h. Find its head, its efficiency, and the hydraulic, shaft and electrical power at that flow.
3. The demand of the site rises to 150 m³ a day and the duty point of Application 1 does not change. Find the running hours, the daily energy and the daily cost.
Hours:
4. The booster of Application 2 is held at 15 m³/h by a valve, at full speed. Find the pump head, the head the valve takes, the pump efficiency and the electrical input.
Pump head
5. In Application 2 the booster is held at 18 m³/h by one valve. Write the head that the valve takes as
The valve takes 8.11 m at 18 m³/h, so
6. After some years the borehole pump is worn and gives 92 percent of its original head at every flow. The system curve is unchanged. Find the new duty point and the new running hours for 110 m³ a day.
Solve
A borehole pump delivers 12.14 m³/h into a tank. In a dry season the water level in the borehole falls by 9 m. The pump, its speed and the pipe are the same. What happens to the flow?
Three questions. Each wrong choice is a mistake people really make, so read the note after you answer.
1. A valve on the borehole rising main is partly closed. It takes 10 m of head at 12 m³/h. The electrical input falls from 5.12 kW to 4.91 kW. The site still needs 110 m³ a day. What happens to the energy used each day?
2. At its duty point the borehole pump gives 2.58 kW to the water, takes 4.20 kW at its shaft and 5.12 kW from the supply. The motor nameplate says 5.5 kW. How heavily is the motor loaded?
3. The order for the booster pump says "18 m³/h at 30 m". The pump is installed and started with every valve open. Its curve is H = 42 − 0.012 Q² and the system needs 22 + 0.0247 Q². Where does it run?