Lesson 5 of 10 22 min read
Found this useful?

The nameplate of a pump says 15 m³/h, and the flow meter on site says 12. The owner thinks the pump is faulty, the supplier says it is not, and the electricity bill is higher than anyone planned. The nameplate gives only one point of a curve, and the pump almost never works at that point. It works where its own curve crosses the curve of the pipe system. This lesson shows how to read a maker’s curve, find that crossing, and calculate the power, the running hours and the energy that follow from it. #PumpCurves #DutyPoint #FluidMechanics

Learning Objectives

By the end of this lesson, you will be able to:

  1. Read the four curves on a maker’s sheet: head, efficiency, power and NPSH required
  2. Solve for the duty point of a pump on a system curve, by formula and numerically
  3. Calculate hydraulic power, shaft power, electrical input and energy per cubic metre at the duty point
  4. Explain the best efficiency point and what happens to a pump that runs far to the left or right of it
  5. Judge how much head a throttling valve throws away at a given flow

Real-World System Problem: A borehole pump and a booster pump



A site takes 110 m³ of water a day from a borehole. A multistage submersible pump, 70 m down, sends the water up a 63 mm rising main to a tank on a stand. A second pump, a single-stage booster at ground level under the tank, supplies the buildings at a flow that changes through the day.

Each pump was bought from a catalogue page that shows a curve, and each pipe system has its own curve, built from levels and friction. Neither alone says what the flow will be. The flow, the head, the efficiency and the power are all fixed at the one point where the two curves cross.

If that point is far from where the pump was designed to work, the owner pays twice: in electricity every hour, and in bearings, seals and impellers some years later.

BoosterTankBoreholepumprising mainsystem curve 1groundsystem curve 2to buildings
Two pumps, two system curves

Fundamental Theory: Two curves and their crossing



What a pump curve says

A centrifugal pump at a fixed speed does not have one head and one flow, but a relation between them. If the pipe system lets much water through, the pump gives little head; if it resists, the pump gives more head and less flow. The maker measures this relation on a test stand and prints it as the pump curve: head in metres against flow in m³/h.

Two ends of the curve have names.

  • Shut-off: zero flow, with the discharge closed. The head here is the shut-off head, the most the pump can produce at that speed.
  • Run-out: the far right end, the largest flow the maker allows. The head is low and the pump should not work beyond this point.

The pump curve belongs to the pump and its speed. It does not know anything about the pipe.

The four curves on a maker’s sheet

A full sheet shows four quantities against the same flow axis.

head Hefficiency(peak at the BEP)shaft powerNPSH requiredQshut-offBEPrun-out
What a maker's curve sheet shows
  • Head falls as flow rises.
  • Efficiency starts at zero at shut-off (no water is delivered), rises to a peak, and falls again.
  • Shaft power is what the motor must give to the pump shaft. For the radial pumps of this course it rises with flow.
  • NPSH required is the pressure margin the pump needs at its inlet to avoid cavitation. It rises quickly at high flow. A later lesson on NPSH and cavitation uses it.

For calculation, a few points read from the head curve are fitted with a quadratic. The borehole pump of this course has three maker’s points, and one quadratic passes through all of them. The efficiency formulas used here have a typical shape, a peak with a fall on both sides. Use the maker’s own efficiency curve when you have it.

The duty point

The system curve is the head the pipes need at each flow. The pump curve is the head the pump gives at each flow. Steady running is possible only where the two are equal.

The duty point

The flow that satisfies this equation, with its head, is the duty point (also called the operating point). The pump and the system choose it together. No setting on the pump chooses it.

Hpump curvesystem●curvestatic headQduty flow
The duty point is the crossing

The crossing is stable. At a flow a little above it, the system needs more head than the pump gives, so the water slows down. A little below it, the pump gives more head than the system needs, so the water speeds up. Either way the flow returns to the crossing, as a ball rolls back to the bottom of a bowl.

When both curves are quadratics, the equation is a quadratic in and can be solved by the usual formula. When one of them is a table or a more complex function, a root finder does the same work. The Python script uses scipy.optimize.brentq, which needs only a function and two flows that bracket the crossing.

A common mistake is to read the duty flow from the pump curve at the “design head” written on the order. The order does not choose the duty point: the curves cross where the levels and valves of that day put them.

From the duty point to power and energy

Once and are known, the power follows in three steps.

Power at the duty point

is the hydraulic power given to the water, with in m³/s, and . is the power at the pump shaft. is the electrical power taken from the supply. Use only when a variable speed drive is fitted. Without a drive it is 1.

The motor rating on a nameplate is shaft power, so compare it with and not with .

The number that follows a pumping system through its life is the specific energy, the electrical energy used for each cubic metre:

The best efficiency point

The flow at which the efficiency peaks is the best efficiency point, or BEP. The impeller blades and the casing are shaped for the water angles and velocities of that one flow. At the BEP the water enters the blades smoothly, leaves them smoothly, and the pressure round the impeller is even.

Away from the BEP the pump still works, but two things get worse together: more of the shaft power becomes heat and turbulence, so each cubic metre costs more energy, and the forces inside the pump grow, so bearings, seals and wear rings live shorter.

A common guide is to keep a pump between about 70 and 120 percent of its BEP flow for continuous running. The maker’s stated range, when given, replaces this guide.

Running far to the left and far to the right

Hfar leftfar rightheating,good_cavitation,recirculation, regionoverloadradial loadnear BEPQlow flowBEPrun-out
Three regions of one pump curve

Far to the left, near shut-off, the pump delivers little water but still takes a large share of its power, and that power can only heat the water inside the casing. At true shut-off all of it becomes heat: a pump left running against a closed valve can boil the water it holds. The flow inside the impeller also breaks down and turns back at the inlet and outlet (recirculation), causing noise, vibration and wear. In a single-volute pump such as the booster, the pressure round the impeller becomes uneven at low flow and pushes the shaft sideways. This radial load bends the shaft a little at every turn and loads the bearings and the seal.

Far to the right, near run-out, the inlet velocity is high and the NPSH required rises steeply. If the system cannot supply that margin, vapour bubbles form and collapse on the impeller: cavitation. The shaft power of a radial pump is also highest here, so a motor sized for the middle of the curve can be overloaded. Pumps reach this region when the system resistance is much lower than expected, for example a burst main or a pump that discharges into an empty pipe.

Application 1: The duty point of the borehole pump



Step 1: Confirm the pump curve

Click to reveal the check of the fit
  1. At zero flow. m, the shut-off head. ✅

  2. At 10 m³/h.

    The formula gives the maker’s 88 m. ✅

  3. At 15 m³/h.

    The formula gives the maker’s 62 m, so it passes through all three points. ✅

Step 2: Solve for the duty point

Click to reveal the crossing of the two curves
  1. Set the pump head equal to the system head.

    Collect the terms on one side:

    The duty flow is the positive root of this quadratic. ✅

  2. Solve.

    The duty flow is 12.14 m³/h, inside the range of the system curve. ✅

  3. Head at the duty point. From the pump curve:

    The system curve gives the same: m. The duty point is 12.14 m³/h at 78.09 m. ✅

  4. Pump efficiency.

    The pump runs at 61.4 percent, at 110 percent of its BEP flow. ✅

Step 3: Power and the motor

Click to reveal the three powers
  1. Convert the flow.

    The flow is 3.37 litres per second. ✅

  2. Hydraulic power.

    The water receives 2.58 kW. ✅

  3. Shaft power.

    The pump shaft takes 4.20 kW. ✅

  4. Electrical input. There is no drive, so only the motor efficiency applies.

    The supply gives 5.12 kW. ✅

  5. Is the 5.5 kW motor adequate? The rating is shaft power. The pump needs 4.20 kW, which is 76 percent of 5.5 kW. Over the whole range from 4 to 16 m³/h, the largest shaft power is 4.77 kW, at 16 m³/h. The motor is adequate at the duty point and is not overloaded anywhere in the range. ✅

Step 4: Energy, hours and cost

Click to reveal the specific energy and the bill
  1. Specific energy.

    Each cubic metre costs 0.422 kWh of electricity. ✅

  2. Running hours.

    The pump must run for 9.06 hours to deliver the daily demand. ✅

  3. Daily energy and cost.

    The borehole pump uses 46.39 kWh a day. ✅

  4. Yearly energy and cost.

    The pump costs about currency units a year to run. ✅

  5. Check a second way. The wire-to-water efficiency is . The energy that the water itself gains is . Divided by 0.5036, this gives 0.4217 kWh/m³, the same as step 1. The Python script finds the same duty point with a root finder. ✅

Application 2: The booster on its system curve



Step 1: The natural duty point

Click to reveal where the pump settles with the valve open
  1. Equal heads.

    With every valve open the pump settles at 23.34 m³/h. ✅

  2. Head and efficiency there.

    The natural duty point is 23.34 m³/h at 35.46 m, at 130 percent of the BEP flow. ✅

  3. Power. kW, so

    The pump takes 3.96 kW from the supply at its natural duty point. ✅

Step 2: Holding 18 m³/h

Click to reveal the surplus head at the design flow
  1. What the pump gives and what the system needs.

    At 18 m³/h the pump gives 8.1 m more than the system needs. ✅

  2. Where the surplus goes. To hold 18 m³/h at full speed, a valve must take the 8.1 m. That is 21 percent of the pump head, turned into heat and noise in the valve. In hydraulic power it is kW. ✅

  3. Power at 18 m³/h, throttled. The efficiency is at its peak, 0.68. kW, so kW and kW. ✅

  4. The other way. A slower pump has a lower curve. At the right speed the curve passes through 18 m³/h at 30.0 m with the valve open, and nothing is thrown away. That is the subject of the next lesson. ✅

Step 3: The two ends of the range

Click to reveal the booster at 6 and 24 m³/h
  1. Points on the pump curve at full speed.

    (m³/h)Pump head (m)System needs (m) (kW) (kW)kWh/m³
    641.5722.890.5071.341.520.253
    1838.1130.000.6802.743.120.173
    2435.0936.230.6373.604.090.170

    The electrical input is 1.52 kW at 6 m³/h and 4.09 kW at 24 m³/h. ✅

  2. The low end. At 6 m³/h the pump is at one third of its BEP flow. It gives 41.57 m, the system needs 22.89 m, and the valve takes 18.68 m, which is 45 percent of the pump head. Each cubic metre costs 0.253 kWh, about one and a half times the cost at 18 m³/h. ✅

  3. The high end. At 24 m³/h the pump gives 35.09 m but the system curve asks for 36.23 m. The pump is 1.14 m short. On this system curve it cannot reach 24 m³/h at full speed: it stops at the natural duty point, 23.34 m³/h. The row for 24 m³/h describes the pump only if the system resistance is a little lower than the curve says. ✅

  4. Check with the script. The Python script solves the natural duty point with a root finder and prints the same table. ✅

Verify It in Python



The script checks the fitted pump curve against the maker’s points, solves both duty points with a root finder, and prints the powers, the energy and the cost. It saves one plot with both pumps.

duty_point.py
"""Duty points: borehole pump on its system curve, and the booster pump."""
import numpy as np
from scipy.optimize import brentq
import matplotlib.pyplot as plt
RHO, G = 998.0, 9.81 # water at 20 degC
PRICE, DAILY = 12.00, 110.0 # currency units per kWh, m3 per day
def power(q_m3h, head, eta_pump, eta_motor):
"""Return hydraulic, shaft and electrical input power in kW."""
p_h = RHO * G * (q_m3h / 3600.0) * head / 1000.0
p_shaft = p_h / eta_pump
return p_h, p_shaft, p_shaft / eta_motor
# ---------- Borehole pump (fixed speed, 2900 rev/min) ----------
def pump_c(q):
return 110.0 - 0.2 * q - 0.2 * q**2
def system_c(q): # valid from 4 to 16 m3/h
return 59.65 + 0.8948 * q + 0.05143 * q**2
def eta_c(q): # typical shape, 4 to 16 m3/h
return 0.62 - 0.0045 * (q - 11.0) ** 2
ETA_MOTOR_C, RATING_C = 0.82, 5.5
print("Maker's points against the fitted pump curve")
for q, h in ((0.0, 110.0), (10.0, 88.0), (15.0, 62.0)):
print(f" Q = {q:4.0f}: maker {h:6.1f} m, formula {pump_c(q):6.2f} m, "
f"difference {pump_c(q) - h:+.2f} m")
q_d = brentq(lambda q: pump_c(q) - system_c(q), 4.0, 16.0)
h_d = pump_c(q_d)
p_h, p_s, p_in = power(q_d, h_d, eta_c(q_d), ETA_MOTOR_C)
sec = p_in / q_d
hours = DAILY / q_d
print("Application 1: borehole duty point")
print(f" Q = {q_d:.2f} m3/h, H = {h_d:.2f} m (system curve gives {system_c(q_d):.2f} m)")
print(f" pump efficiency = {eta_c(q_d):.4f}")
print(f" hydraulic {p_h:.3f} kW, shaft {p_s:.3f} kW, electrical input {p_in:.3f} kW")
print(f" shaft power is {100 * p_s / RATING_C:.0f} % of the {RATING_C} kW rating")
qq = np.linspace(4.0, 16.0, 241)
p_all = np.array([power(q, pump_c(q), eta_c(q), ETA_MOTOR_C)[1] for q in qq])
print(f" largest shaft power from 4 to 16 m3/h = {p_all.max():.2f} kW "
f"at {qq[p_all.argmax()]:.0f} m3/h")
print(f" wire-to-water efficiency = {eta_c(q_d) * ETA_MOTOR_C:.3f}")
print(f" specific energy = {sec:.4f} kWh/m3")
print(f" running time for {DAILY:.0f} m3 = {hours:.2f} h a day")
print(f" energy = {sec * DAILY:.2f} kWh a day, {sec * DAILY * 365:.0f} kWh a year")
print(f" cost = {sec * DAILY * PRICE:.0f} a day, {sec * DAILY * 365 * PRICE:.0f} a year")
a, b, c = 0.2 + 0.05143, 0.2 + 0.8948, 59.65 - 110.0
print(f" check by the quadratic formula: Q = "
f"{(-b + np.sqrt(b * b - 4 * a * c)) / (2 * a):.2f} m3/h")
# ---------- Booster pump (fixed speed, no drive) ----------
def pump_e(q):
return 42.0 - 0.012 * q**2
def system_e(q):
return 22.0 + 0.0247 * q**2
def eta_e(q):
return 0.68 - 0.0012 * (q - 18.0) ** 2
ETA_MOTOR_E = 0.88
q_n = brentq(lambda q: pump_e(q) - system_e(q), 1.0, 40.0)
p_h, p_s, p_in = power(q_n, pump_e(q_n), eta_e(q_n), ETA_MOTOR_E)
print("Application 2: booster at full speed")
print(f" natural duty point: Q = {q_n:.2f} m3/h, H = {pump_e(q_n):.2f} m, "
f"efficiency {eta_e(q_n):.4f}, shaft {p_s:.3f} kW, input {p_in:.3f} kW")
for q in (6.0, 18.0, 24.0):
p_h, p_s, p_in = power(q, pump_e(q), eta_e(q), ETA_MOTOR_E)
print(f" Q = {q:4.0f}: pump {pump_e(q):.2f} m, system {system_e(q):.2f} m, "
f"surplus {pump_e(q) - system_e(q):+.2f} m, efficiency {eta_e(q):.4f}, "
f"shaft {p_s:.3f} kW, input {p_in:.3f} kW, {p_in / q:.3f} kWh/m3")
p_valve = RHO * G * (18.0 / 3600.0) * (pump_e(18.0) - system_e(18.0)) / 1000.0
print(f" at 18 m3/h the valve destroys {p_valve:.3f} kW of hydraulic power, "
f"{100 * (pump_e(18.0) - system_e(18.0)) / pump_e(18.0):.1f} % of the pump head")
# ---------- Plot ----------
fig, ax = plt.subplots(1, 2, figsize=(10, 4.5))
q1 = np.linspace(4.0, 16.0, 100)
ax[0].plot(q1, pump_c(q1), label="pump curve")
ax[0].plot(q1, system_c(q1), label="system curve")
ax[0].plot(q_d, h_d, "o", color="black", label="duty point")
ax[0].set_title("Borehole pump")
q2 = np.linspace(0.0, 28.0, 100)
ax[1].plot(q2, pump_e(q2), label="pump curve")
ax[1].plot(q2, system_e(q2), label="system curve")
ax[1].plot(q_n, pump_e(q_n), "o", color="black", label="natural duty point")
ax[1].plot([18.0, 18.0], [system_e(18.0), pump_e(18.0)], "k:", label="head lost in the valve")
ax[1].set_title("Booster pump")
for axis in ax:
axis.set_xlabel("flow (m3/h)")
axis.set_ylabel("head (m)")
axis.legend()
fig.tight_layout()
fig.savefig("duty_point.png", dpi=120)
print("Saved duty_point.png")

Expected output

Maker's points against the fitted pump curve
Q = 0: maker 110.0 m, formula 110.00 m, difference +0.00 m
Q = 10: maker 88.0 m, formula 88.00 m, difference +0.00 m
Q = 15: maker 62.0 m, formula 62.00 m, difference +0.00 m
Application 1: borehole duty point
Q = 12.14 m3/h, H = 78.09 m (system curve gives 78.09 m)
pump efficiency = 0.6141
hydraulic 2.578 kW, shaft 4.198 kW, electrical input 5.120 kW
shaft power is 76 % of the 5.5 kW rating
largest shaft power from 4 to 16 m3/h = 4.77 kW at 16 m3/h
wire-to-water efficiency = 0.504
specific energy = 0.4217 kWh/m3
running time for 110 m3 = 9.06 h a day
energy = 46.39 kWh a day, 16932 kWh a year
cost = 557 a day, 203186 a year
check by the quadratic formula: Q = 12.14 m3/h
Application 2: booster at full speed
natural duty point: Q = 23.34 m3/h, H = 35.46 m, efficiency 0.6457, shaft 3.486 kW, input 3.962 kW
Q = 6: pump 41.57 m, system 22.89 m, surplus +18.68 m, efficiency 0.5072, shaft 1.337 kW, input 1.520 kW, 0.253 kWh/m3
Q = 18: pump 38.11 m, system 30.00 m, surplus +8.11 m, efficiency 0.6800, shaft 2.744 kW, input 3.118 kW, 0.173 kWh/m3
Q = 24: pump 35.09 m, system 36.23 m, surplus -1.14 m, efficiency 0.6368, shaft 3.596 kW, input 4.087 kW, 0.170 kWh/m3
at 18 m3/h the valve destroys 0.397 kW of hydraulic power, 21.3 % of the pump head
Saved duty_point.png

The script carries all digits, so its yearly cost is , against the of the hand calculation. In the right plot the dotted line at 18 m³/h is the head that the throttling valve must take.

Common Mistakes



  • Taking the flow on the nameplate as the flow on site. The nameplate is one point of the curve, and the system decides which point the pump works at.
  • Solving the duty point with a system curve outside the range it was fitted for. Check that the answer lies inside the range.
  • Comparing the motor rating with the electrical input. The rating is shaft power, so compare it with .
  • Leaving the flow in m³/h inside . The power comes out 3,600 times too large.
  • Believing that a throttled pump saves energy in proportion to the flow. The input power falls a little, but the energy for each cubic metre rises.
  • Running a pump against a closed valve for more than the short time the maker allows. All the shaft power turns into heat in the casing.

Summary



  • A pump curve gives the head a pump produces at each flow at one speed. A maker’s sheet adds efficiency, shaft power and NPSH required.
  • The duty point is where the pump curve crosses the system curve. It is found by solving .
  • The borehole pump works at 12.14 m³/h and 78.09 m, with a pump efficiency of 61.4 percent, a shaft power of 4.20 kW and an electrical input of 5.12 kW.
  • That is 0.4217 kWh for each cubic metre, 9.06 hours a day for 110 m³, and about currency units a year.
  • The best efficiency point is the flow the pump was shaped for. Far to the left the pump heats, recirculates and carries a radial load. Far to the right it can cavitate and overload its motor.
  • The booster at full speed settles at 23.34 m³/h. To hold 18 m³/h a valve must take 8.1 m of head, unless the pump is slowed.

Exercises



1. A pump has the curve and its system has the curve , with in m³/h. Find the duty point.

Answer

, so m³/h. The head is m.

2. The borehole pump of Application 1 is tested at 10 m³/h. Find its head, its efficiency, and the hydraulic, shaft and electrical power at that flow.

Answer

m and . kW. kW and kW.

3. The demand of the site rises to 150 m³ a day and the duty point of Application 1 does not change. Find the running hours, the daily energy and the daily cost.

Answer

Hours: h. Energy: kWh a day. Cost: currency units a day.

4. The booster of Application 2 is held at 15 m³/h by a valve, at full speed. Find the pump head, the head the valve takes, the pump efficiency and the electrical input.

Answer

Pump head m. The system needs m, so the valve takes 11.74 m. . kW, kW, kW.

5. In Application 2 the booster is held at 18 m³/h by one valve. Write the head that the valve takes as and find . Then write the system curve with the valve in that position.

Answer

The valve takes 8.11 m at 18 m³/h, so m per (m³/h)². The system curve becomes . The valve has doubled the resistance of the system.

6. After some years the borehole pump is worn and gives 92 percent of its original head at every flow. The system curve is unchanged. Find the new duty point and the new running hours for 110 m³ a day.

Answer

Solve , which is . The positive root is m³/h, at m. Running hours: h a day. A loss of 8 percent of head has cost 7.8 percent of the flow.

References



  • I. J. Karassik, J. P. Messina, P. Cooper and C. C. Heald, Pump Handbook, 4th edition, McGraw-Hill, 2008.
  • F. M. White, Fluid Mechanics, 8th edition, McGraw-Hill, 2016.
  • Y. A. Çengel and J. M. Cimbala, Fluid Mechanics: Fundamentals and Applications, 4th edition, McGraw-Hill, 2018.
  • J. F. Gülich, Centrifugal Pumps, 3rd edition, Springer, 2014.


© 2021-2026 SiliconWit®. All rights reserved.
Predict first

A borehole pump delivers 12.14 m³/h into a tank. In a dry season the water level in the borehole falls by 9 m. The pump, its speed and the pipe are the same. What happens to the flow?

See it: the duty point is where the curves cross

Flow
Head
Pump efficiency
Lost in the valve
Shaft power
Electrical input
Energy for each m³
Running time for 110 m³

051015flow, m³/h 4080120head, m runs here: 12.1 m³/h nameplate: 15 m³/h pumpsystem
051015flow, m³/h 4080120head, m BEP heating,recirculation cavitation,overload 70 to 120 %

Check yourself

Three questions. Each wrong choice is a mistake people really make, so read the note after you answer.

1. A valve on the borehole rising main is partly closed. It takes 10 m of head at 12 m³/h. The electrical input falls from 5.12 kW to 4.91 kW. The site still needs 110 m³ a day. What happens to the energy used each day?

2. At its duty point the borehole pump gives 2.58 kW to the water, takes 4.20 kW at its shaft and 5.12 kW from the supply. The motor nameplate says 5.5 kW. How heavily is the motor loaded?

3. The order for the booster pump says "18 m³/h at 30 m". The pump is installed and started with every valve open. Its curve is H = 42 − 0.012 Q² and the system needs 22 + 0.0247 Q². Where does it run?

Watch it build: the borehole pump on its system
H (m) Q (m³/h) pump system 12.1 78 62 m needs 84.6 m 15 water 2.58, shaft 4.20supply 5.12 kW 5.12 kW ÷ 12.1 m³/h= 0.42 kWh/m³
  1. The pump curve falls from 110 m; the system curve rises from 60 m.
  2. They cross at 12.1 m³/h and 78.1 m. Any other flow drifts back to it.
  3. At the 15 m³/h on the order, the pump gives 62 m but the pipe needs 84.6 m.
  4. At the crossing: 2.58 kW to the water, 4.20 kW at the shaft, 5.12 kW from the supply.
  5. The supply power over the flow: 5.12 ÷ 12.1 = 0.42 kWh for each cubic metre.
tank booster to the buildings system curve 2 rising main system curve 1 ground borehole pump, multistage, 70 m down
Two pumps, two system curves
0 60 120 head H, m 0 % 31 % 62 % efficiency 0 3 6 shaft power, kW 0 3 6 NPSH required, m peak at the BEP shut-off BEP, 11 m³/h run-out Q, m³/h
What a maker's curve sheet shows (head from this lesson; the other shapes typical)
0 40 80 120 H, m BEP shut-off 7.7 11 13.2 run-out Q, m³/h far left heating, recirculation, radial load good region near the BEP, 70 to 120 % far right cavitation, overload
Three regions of one pump curve
Found this useful?