The affinity laws for one pump
The Affinity Laws and Speed Control
On this page
A variable speed drive is sold with one sentence: at 80 percent speed the pump uses half the power. The drive is fitted to a borehole pump, the meter is read after a month, and the saving is a few percent. The sentence was true for a different kind of system. The rule behind it, the cube law, describes the pump correctly, but it cannot say where a real pipe system will let the pump work. This lesson gives the three affinity laws, shows where they hold, and uses them with the system curve to find the true speed, power and saving for two pumps. #AffinityLaws #SpeedControl #PumpEnergy
Learning Objectives
By the end of this lesson, you will be able to:
- State the three affinity laws and the conditions under which they hold
- Write the curve of a pump at any speed from its curve at full speed
- Solve for the speed that delivers a wanted flow on a system curve with static head
- Compare the electrical input of a throttled pump with a speed-controlled pump, including the drive loss
- Explain why the cube law overstates the saving when the static head is high, and find the minimum useful speed
Real-World System Problem: A booster that is throttled all day
A booster pump under a storage tank supplies a group of buildings. It was chosen for the highest demand, but for most of the day the buildings take much less, and a valve after the pump is part closed to hold the flow down. The pump makes more head than the buildings need, and the valve turns the surplus into heat and noise.
The other way is to turn the pump more slowly: a slower pump makes less head, so there is no surplus to destroy. A variable speed drive does this by changing the frequency of the motor supply.
Whether the drive is worth its price depends most on how much of the system head is static. The same drive that cuts the input of this booster by more than a third does very little for the borehole pump that fills the tank.
Fundamental Theory: One pump at many speeds
Why speed scales everything
Inside a centrifugal pump, every water velocity is tied to the speed of the impeller tip. Turn the impeller at 90 percent of the speed, and if the flow pattern keeps the same shape, every velocity is 90 percent of what it was.
Three results follow. The flow is a velocity times an area, so the flow scales with the speed. The head comes from velocity squared (as in
Write
Where the laws hold
The laws connect pairs of corresponding points. They do not connect any two points you choose. Eliminate
All the points that correspond to each other lie on one parabola through the origin, the affinity parabola. Along that parabola the efficiency is constant and the three laws hold.
The limits are these.
- The same pump, the same impeller diameter, the same liquid.
- Efficiency is only nearly constant. At much reduced speed, friction in bearings and seals and the lower Reynolds number inside the pump take a larger share, so a small pump at half speed is a few points less efficient than the laws say.
- No cavitation at either point.
- The laws give shaft power. Motor and drive losses are added afterwards.
The pump curve at any speed
Take any point
For a full-speed curve
The booster of this course has
The shut-off head falls with
The mistake: the cube law on a system with static head
The cube law says that the shaft power follows
The working point does not choose its path: it is always on the system curve. It moves along an affinity parabola only when the system curve is itself a parabola through the origin,
With static head, the system curve starts above the origin and is flatter than the affinity parabola. A small fall of speed then causes a large fall of flow, the flow reaches zero while the pump still turns quickly, and the power at a wanted flow is higher than the cube law predicts.
The correct method has two steps. First find the new working point from the system curve. Then use the affinity laws only to learn what the pump does at that point.
Efficiency at reduced speed
The efficiency formula of a pump is given at full speed, as a function of flow. At reduced speed, do not put the actual flow into it: follow the affinity parabola from the working point back to full speed. The corresponding full-speed flow is
and the efficiency at the working point is the full-speed efficiency at
Throttling against speed control
A throttling valve adds resistance. The working point climbs the full-speed pump curve to the left, to point T, and the valve destroys the difference between T and the system curve. It is like driving with the accelerator pressed and the brake on.
Speed control lowers the pump curve until it crosses the system curve at the wanted flow, point S. The pump makes only the head the system needs, so the hydraulic power falls by the ratio of the two heads, and the pump often runs nearer its best efficiency point too.
Speed control is not free. A drive loses about 3 percent of the power that passes through it, at full speed too. This course takes the motor efficiency as constant at part load, a simplification. The sister course on electrical power treats variable speed drives and motor efficiency in its own lessons.
Minimum speed
A pump moves water only if its shut-off head is above the static head of the system. For the booster, with 22 m of static head:
Below that speed the pump turns, heats the water in its casing, and delivers nothing. The practical minimum is higher: just above the limit the pump works close to shut-off, with its recirculation and heating, and makers of motors and pumps state a minimum speed for cooling and bearings. Set the lower limit of the drive from these, not from zero.
Application 1: The booster at 12 m³/h, throttled or slowed
Step 1: Throttled at full speed
Click to reveal the throttled case
-
Pump head at 12 m³/h.
The system needs
m, so the valve takes 14.72 m. ✅ -
Pump efficiency.
The pump runs at 63.7 percent. ✅
-
Power. The flow is
. Throttled, the booster takes 2.345 kW from the supply. ✅
Step 2: Speed controlled
Click to reveal the speed and the power
-
Solve for the speed ratio. The slow pump curve must pass through 12 m³/h at 25.56 m.
The pump must turn at
rev/min, a supply frequency of about 40.3 Hz. ✅ -
Efficiency by the equivalent full-speed flow.
The slowed pump runs at 66.8 percent, better than the throttled pump. ✅
-
Power. The head is now only what the system needs.
With speed control the booster takes 1.462 kW, drive loss included. ✅
-
Check a second way. Use the cube law correctly, along the affinity parabola. At full speed and 14.89 m³/h the pump gives
m, and its shaft power is kW. Multiply by : the result is 1.248 kW, the same as step 3. ✅
Step 3: The bare cube law, the saving and the minimum speed
Click to reveal the comparison
-
The bare cube law. At full speed and 18 m³/h the pump gives 38.11 m at 68 percent, a shaft power of 2.744 kW. The bare cube law says: for two thirds of the flow, use two thirds of the speed.
The true shaft power at 12 m³/h is 1.248 kW, which is 54 percent more than this prediction. ✅
-
Why it is wrong. At two thirds of full speed the shut-off head is
m. That is below the 22 m of static head. At the speed the cube law assumes, this pump would deliver no water at all. The real speed for 12 m³/h is 80.6 percent, not 66.7 percent. ✅ -
Saving.
Speed control saves 0.883 kW, which is 37.7 percent of the throttled input. ✅
-
Yearly saving.
Over 3,000 hours at this flow the drive saves about
currency units a year. ✅ -
Minimum speed.
Below
rev/min, about 36.2 Hz, the booster delivers nothing. ✅
Application 2: The borehole pump slowed to 9 m³/h
Step 1: The speed for 9 m³/h
Click to reveal the speed ratio
-
Head the system needs at 9 m³/h.
The system needs 71.87 m, against 78.09 m at full speed. ✅
-
Pump curve at speed ratio
. The curve has a linear term, so all three terms scale: At
: . ✅ -
Solve.
The pump must turn at
rev/min, about 45.1 Hz. ✅ -
Read the result. The flow falls by 26 percent for a fall of speed of less than 10 percent. This is what a flat system curve does. ✅
Step 2: Power and specific energy
Click to reveal the energy for each cubic metre
-
Efficiency by the equivalent full-speed flow.
The pump efficiency is 61.5 percent, almost the same as the 61.4 percent at full speed. ✅
-
Power. The flow is
. The slowed pump takes 3.595 kW. ✅
-
Specific energy.
Against 0.4217 kWh/m³ at full speed, the energy for each cubic metre falls by 5.3 percent. ✅
-
Over a year. The pump now runs
hours a day and not 9.06. The daily energy is kWh against 46.39 kWh. The saving is 895 kWh a year, about currency units, on a bill of about . ✅ -
Check a second way. The water gains
. The wire-to-water efficiency is . The ratio is 0.3994 kWh/m³, as in step 3. ✅
Verify It in Python
The script solves the speed ratio for each pump with a root finder, calculates the powers with the equivalent-flow method, and prints the comparisons. It saves one plot with the pump curves at the speeds found.
"""Speed control against throttling: the booster pump and the borehole pump."""import numpy as npfrom scipy.optimize import brentqimport matplotlib.pyplot as plt
RHO, G = 998.0, 9.81 # water at 20 degCPRICE = 12.00 # currency units per kWhN_FULL, F_FULL = 2900.0, 50.0 # rev/min and Hz at full speedETA_DRIVE = 0.97
def power(q_m3h, head, eta_pump, eta_motor, eta_drive=1.0): """Return hydraulic, shaft and electrical input power in kW.""" p_h = RHO * G * (q_m3h / 3600.0) * head / 1000.0 p_shaft = p_h / eta_pump return p_h, p_shaft, p_shaft / (eta_motor * eta_drive)
# ---------- Booster pump ----------def pump_e(q, r=1.0): # affinity laws applied to 42 - 0.012 Q^2 return 42.0 * r**2 - 0.012 * q**2
def system_e(q): return 22.0 + 0.0247 * q**2
def eta_e(q_full): # efficiency at the full-speed flow return 0.68 - 0.0012 * (q_full - 18.0) ** 2
ETA_MOTOR_E = 0.88Q = 12.0print("Application 1: booster delivering 12 m3/h")ph_a, ps_a, pin_a = power(Q, pump_e(Q), eta_e(Q), ETA_MOTOR_E)print(f" (a) throttled: pump head {pump_e(Q):.2f} m, system needs {system_e(Q):.2f} m, " f"valve takes {pump_e(Q) - system_e(Q):.2f} m")print(f" efficiency {eta_e(Q):.4f}, hydraulic {ph_a:.3f} kW, shaft {ps_a:.3f} kW, " f"input {pin_a:.3f} kW")r = brentq(lambda x: pump_e(Q, x) - system_e(Q), 0.3, 1.2)q_eq = Q / rph_b, ps_b, pin_b = power(Q, system_e(Q), eta_e(q_eq), ETA_MOTOR_E, ETA_DRIVE)print(f" (b) speed controlled: r = {r:.4f}, {N_FULL * r:.0f} rev/min, {F_FULL * r:.1f} Hz")print(f" equivalent full-speed flow {q_eq:.2f} m3/h, efficiency {eta_e(q_eq):.4f}")print(f" hydraulic {ph_b:.3f} kW, shaft {ps_b:.3f} kW, input {pin_b:.3f} kW")ph18, ps18, pin18 = power(18.0, pump_e(18.0), eta_e(18.0), ETA_MOTOR_E)cube = ps18 * (Q / 18.0) ** 3print(f" (c) full speed at 18 m3/h: head {pump_e(18.0):.2f} m, shaft {ps18:.3f} kW")print(f" bare cube law to 12 m3/h: shaft {cube:.3f} kW " f"(true value is {100 * (ps_b / cube - 1):.0f} % higher)")print(f" shut-off head at r = 2/3 is {pump_e(0.0, 2 / 3):.2f} m, below the 22 m static head")saving = pin_a - pin_bprint(f" saving {saving:.3f} kW, {100 * saving / pin_a:.1f} %; over 3000 h: " f"{saving * 3000:.0f} kWh, {saving * 3000 * PRICE:.0f} currency units")print(f" specific energy: throttled {pin_a / Q:.4f}, speed controlled {pin_b / Q:.4f} kWh/m3")r_min = np.sqrt(22.0 / 42.0)print(f" minimum speed for any flow: r = {r_min:.4f}, {N_FULL * r_min:.0f} rev/min, " f"{F_FULL * r_min:.1f} Hz")
# ---------- Borehole pump ----------def pump_c(q, r=1.0): # affinity laws applied to the maker's fit return 110.0 * r**2 - 0.2 * r * q - 0.2 * q**2
def system_c(q): # valid from 4 to 16 m3/h return 59.65 + 0.8948 * q + 0.05143 * q**2
def eta_c(q_full): return 0.62 - 0.0045 * (q_full - 11.0) ** 2
ETA_MOTOR_C = 0.82q_d = brentq(lambda q: pump_c(q) - system_c(q), 4.0, 16.0)ph_d, ps_d, pin_d = power(q_d, pump_c(q_d), eta_c(q_d), ETA_MOTOR_C)print("Application 2: borehole pump")print(f" full speed, no drive: Q = {q_d:.2f} m3/h, H = {pump_c(q_d):.2f} m, " f"input {pin_d:.3f} kW, {pin_d / q_d:.4f} kWh/m3")Q9 = 9.0r9 = brentq(lambda x: pump_c(Q9, x) - system_c(Q9), 0.75, 1.0)q_eq9 = Q9 / r9ph9, ps9, pin9 = power(Q9, system_c(Q9), eta_c(q_eq9), ETA_MOTOR_C, ETA_DRIVE)print(f" 9 m3/h: system head {system_c(Q9):.2f} m, r = {r9:.4f}, " f"{N_FULL * r9:.0f} rev/min, {F_FULL * r9:.1f} Hz")print(f" equivalent full-speed flow {q_eq9:.2f} m3/h, efficiency {eta_c(q_eq9):.4f}")print(f" hydraulic {ph9:.3f} kW, shaft {ps9:.3f} kW, input {pin9:.3f} kW, " f"{pin9 / Q9:.4f} kWh/m3")change = 100 * (pin9 / Q9 - pin_d / q_d) / (pin_d / q_d)print(f" specific energy changes by {change:+.1f} %, head by " f"{100 * (system_c(Q9) / pump_c(q_d) - 1):+.1f} %")print(f" hours for 110 m3: {110 / q_d:.2f} at full speed, {110 / Q9:.2f} at 9 m3/h")e_full, e_slow = 110 * pin_d / q_d, 110 * pin9 / Q9print(f" daily energy {e_full:.2f} against {e_slow:.2f} kWh; yearly saving " f"{(e_full - e_slow) * 365:.0f} kWh, {(e_full - e_slow) * 365 * PRICE:.0f} currency units")print(f" drawdown {8.0 / 12.0 * q_d:.2f} m at full speed, {8.0 / 12.0 * Q9:.2f} m at 9 m3/h")print(f" a pure friction loop would change specific energy by " f"{100 * ((Q9 / q_d) ** 2 - 1):+.0f} %")
# ---------- Plot ----------fig, ax = plt.subplots(1, 2, figsize=(10, 4.5))qe = np.linspace(0.0, 26.0, 200)for ratio in (1.0, 0.9, r, r_min): ax[0].plot(qe, pump_e(qe, ratio), label=f"pump, r = {ratio:.3f}")ax[0].plot(qe, system_e(qe), "k", label="system curve")ax[0].plot(qe, system_e(Q) * (qe / Q) ** 2, "k:", label="affinity parabola")ax[0].plot([Q, Q], [system_e(Q), pump_e(Q)], "o--", color="black")ax[0].set_ylim(0, 45)ax[0].set_title("Booster pump at 12 m3/h")qc = np.linspace(4.0, 16.0, 200)ax[1].plot(qc, pump_c(qc), label="pump, full speed")ax[1].plot(qc, pump_c(qc, r9), label=f"pump, r = {r9:.3f}")ax[1].plot(qc, system_c(qc), "k", label="system curve")ax[1].plot([q_d, Q9], [pump_c(q_d), system_c(Q9)], "o", color="black")ax[1].set_ylim(40, 110)ax[1].set_title("Borehole pump")for axis in ax: axis.set_xlabel("flow (m3/h)") axis.set_ylabel("head (m)") axis.legend(fontsize=8)fig.tight_layout()fig.savefig("speed_control.png", dpi=120)print("Saved speed_control.png")Expected output
Application 1: booster delivering 12 m3/h (a) throttled: pump head 40.27 m, system needs 25.56 m, valve takes 14.72 m efficiency 0.6368, hydraulic 1.314 kW, shaft 2.064 kW, input 2.345 kW (b) speed controlled: r = 0.8060, 2337 rev/min, 40.3 Hz equivalent full-speed flow 14.89 m3/h, efficiency 0.6684 hydraulic 0.834 kW, shaft 1.248 kW, input 1.462 kW (c) full speed at 18 m3/h: head 38.11 m, shaft 2.744 kW bare cube law to 12 m3/h: shaft 0.813 kW (true value is 54 % higher) shut-off head at r = 2/3 is 18.67 m, below the 22 m static head saving 0.883 kW, 37.7 %; over 3000 h: 2650 kWh, 31803 currency units specific energy: throttled 0.1954, speed controlled 0.1218 kWh/m3 minimum speed for any flow: r = 0.7237, 2099 rev/min, 36.2 HzApplication 2: borehole pump full speed, no drive: Q = 12.14 m3/h, H = 78.09 m, input 5.120 kW, 0.4217 kWh/m3 9 m3/h: system head 71.87 m, r = 0.9030, 2619 rev/min, 45.1 Hz equivalent full-speed flow 9.97 m3/h, efficiency 0.6152 hydraulic 1.759 kW, shaft 2.859 kW, input 3.595 kW, 0.3994 kWh/m3 specific energy changes by -5.3 %, head by -8.0 % hours for 110 m3: 9.06 at full speed, 12.22 at 9 m3/h daily energy 46.39 against 43.94 kWh; yearly saving 895 kWh, 10741 currency units drawdown 8.09 m at full speed, 6.00 m at 9 m3/h a pure friction loop would change specific energy by -45 %Saved speed_control.pngThe script carries all digits, so its yearly values (
Common Mistakes
- Applying the cube law to the flow of a system with static head. First find the working point on the system curve, then calculate the power there.
- Putting the actual flow at reduced speed into the full-speed efficiency formula. Use the equivalent full-speed flow
. - Scaling only the constant term of a pump curve with
when the curve has a linear term. The linear term scales with . - Forgetting the drive loss, which is also present at full speed. A pump that always runs at full speed uses more energy with a drive than without one.
- Quoting the fall of input power as the saving when the pump must then run for more hours. Compare the energy for each cubic metre.
- Setting the minimum frequency of the drive without checking the static head. Below the speed where the shut-off head equals the static head, the pump delivers nothing.
Summary
- For corresponding points of one pump, flow follows the speed ratio, head its square, and shaft power its cube. Corresponding points lie on a parabola through the origin, with constant efficiency.
- A full-speed curve
becomes at speed ratio . - The working point of a slowed pump is where the new pump curve crosses the system curve. With static head, that point is not the one the bare cube law assumes.
- The booster at 12 m³/h takes 2.345 kW throttled and 1.462 kW at 80.6 percent speed, a saving of 37.7 percent. Below 72.4 percent speed it delivers nothing.
- The borehole pump slowed to 9 m³/h uses 0.3994 kWh/m³ against 0.4217 kWh/m³, only 5.3 percent less, because about 60 m of its head is static.
Exercises
1. A pump delivers 20 m³/h at 30 m with a shaft power of 2.5 kW at 2,900 rev/min. Find the corresponding point at 2,320 rev/min.
Answer
2. Write the curve of the booster of Application 1 at 90 percent speed. Find its shut-off head and its duty point on the system curve with all valves open.
Answer
3. Find the speed at which the booster delivers 15 m³/h with no throttling, the pump efficiency there, and the electrical input with the drive.
Answer
The system needs
4. At 15 m³/h, throttled at full speed, the booster takes 2.722 kW. Using the result of Exercise 3, find the saving in kW and the yearly saving for 2,000 hours at 12.00 currency units per kWh.
Answer
Saving
5. The true static lift of the borehole installation at zero flow is 60 m, and the shut-off head of the borehole pump at full speed is 110 m. Find the speed below which the pump delivers no water.
Answer
6. The borehole pump is held at 9 m³/h by a throttling valve at full speed, with no drive. Find the pump head, the head the valve takes, the electrical input and the specific energy. Compare with the 0.3994 kWh/m³ of speed control and the 0.4217 kWh/m³ of the free duty point.
Answer
Pump head
References
- I. J. Karassik, J. P. Messina, P. Cooper and C. C. Heald, Pump Handbook, 4th edition, McGraw-Hill, 2008.
- F. M. White, Fluid Mechanics, 8th edition, McGraw-Hill, 2016.
- Y. A. Çengel and J. M. Cimbala, Fluid Mechanics: Fundamentals and Applications, 4th edition, McGraw-Hill, 2018.
- J. F. Gülich, Centrifugal Pumps, 3rd edition, Springer, 2014.
A borehole pump lifts water about 60 m into a tank. A drive slows it so that it delivers 9 m³/h in place of 12.14 m³/h, and its input power falls by about 30 percent. The site still needs 110 m³ a day. By about how much does the energy bill fall?
The curves are the lesson's own. Both methods deliver the chosen flow. With a valve, the pump stays at full speed on its solid curve at T, and the valve burns the gap down to the system curve. With a drive, the pump curve is lowered until it crosses the system curve at S. Pump efficiency uses the equivalent full-speed flow Q / r, the motor efficiency is constant, and the drive loses 3 percent.
Check yourself
Three questions. Each wrong choice is a mistake people really make, so read the note after you answer.
1. A pump takes 2.5 kW at its shaft at 2,900 rev/min. What shaft power does it take at the corresponding point at 2,610 rev/min?
2. A booster has a shut-off head of 50 m at 50 Hz. The system has 32 m of static head. Below what supply frequency does the booster deliver no water at all?
3. Two pumps both deliver 18 m³/h at 30 m. Pump A circulates chilled water in a closed loop, all friction. Pump B lifts water and holds a tap pressure: 22 m of its 30 m is static. A drive slows each to 12 m³/h. Which is true?
- Full speed: point 1, 23.3 m³/h at 35.5 m. The cube law promises half the power at 80 % speed.
- The working point stays on the system curve, which starts at 22 m, not on the dashed parabola.
- At 0.8 speed the system puts the pump at point 2, 11.5 m³/h: 49 % of the flow.
- For 12 m³/h the system needs 25.6 m, so r = 0.806. The flow ratio 0.514 delivers nothing.
Discussion
No comments yet. Questions, results from your own build, a better way to explain it: all welcome.
My notes on this page
Kept on this device only. Nothing is sent anywhere.
Tip: select words in the lesson, or tap a figure or an equation, to put a note right there.
Notes on earlier wording
The lesson has changed and these words are no longer in it. Your notes are kept, with the words you chose.