Skip to content
You Start with one site
Amounts in Start with one site
Control, Measurement & Energy · Course

Envelope Analysis

Lesson 7 of 10 23 min read
Found this useful?

A technician calculates the outer-race frequency of a motor bearing, opens the spectrum, and finds nothing at that frequency. The report says the bearing is good. Six weeks later the bearing fails and the compressor stops for two days. The defect was in the signal all the time, but it was not where the technician looked. This lesson explains where the impacts of a damaged bearing go in the spectrum, and gives the four steps of envelope analysis that bring the fault frequency back into view. #VibrationAnalysis #EnvelopeAnalysis #BearingFaults

Learning Objectives

By the end of this lesson, you will be able to:

  1. Explain why bearing impacts give almost no line at the fault frequency in an ordinary spectrum
  2. Apply the four steps of envelope analysis with scipy: band-pass filter, envelope, mean removal, spectrum
  3. Choose the filter band from the ordinary spectrum and from a healthy reading
  4. Read an envelope spectrum: the fault frequency, its multiples and its sidebands at running speed
  5. State where the method stops: low speed, noise, sensor bandwidth and mounting

Real-World System Problem: The drive-end bearing of a compressor motor



Machine A of this course is a 22 kW, 4 pole compressor motor that runs at 1465 rev/min, so its running frequency is . Its drive-end bearing is a 6309. With typical catalogue geometry (8 balls of 17.46 mm on a pitch diameter of 72.5 mm, contact angle 0°; the maker’s data decides), a defect on the outer race is struck 74.15 times each second and a defect on the inner race 121.19 times each second.

A small defect gives a small impact, a fraction of a millisecond long, with little energy, while the rotor’s unbalance pushes on the bearing all the time. In the overall reading and the ordinary spectrum the unbalance is far larger, and the young defect adds almost nothing.

But the impact is sharp, so it makes the housing ring at its own natural frequency, as a hammer makes a bell ring: some thousands of hertz, far from running speed. Envelope analysis looks there.

impact at each ball pass (74.15 per second)outer race●defectballs○○○○○○○○inner race (turns at 24.42 Hz)sharp forceBearing housingrings near(a resonance)3,200 HzAccelerometerto the analyser
From the defect to the sensor

Fundamental Theory: Recovering the repetition from the ringing



An impact is not a sine

A spectrum line at 74 Hz needs a smooth motion repeating 74 times a second. A defect gives a short burst of ringing, then silence, then another burst. The bursts are apart, but inside each the housing moves at its own resonance, about 3,200 Hz in our signal.

Impactstime13.5 msSignalringing at 3,200 Hz in each burstEnveloperepeats 74 times a second
Impacts, bursts and the envelope

So the energy is near 3,200 Hz, and 74 is present only as the rate at which the bursts repeat. The ordinary spectrum shows a broad hump round the resonance, made of fine lines 74 Hz apart, and almost nothing at 74 Hz itself.

The resonance as a carrier

A radio signal works the same way: the message slowly changes the size of a high-frequency carrier, and the receiver recovers it by following the carrier’s outline. Here the resonance is the carrier and the train of impacts the message. This is amplitude modulation; recovering the message is demodulation.

Write the signal near the resonance as

where is the acceleration in , is the resonance frequency in Hz, is a phase angle, and is the envelope: the slowly changing size of the ringing. jumps up at each impact and decays before the next one, so it repeats at the fault frequency. The spectrum of alone has a line at the fault frequency.

The four steps

RemovemeanSpectrum(FFT)Envelope(Hilbert)Band-passfiltera(t)envelopespectrum
The envelope analysis chain

Step one: band-pass filter round the resonance. The filter keeps the band that holds the ringing and removes running speed, its multiples, and noise outside the band. Without this step the envelope follows the largest thing in the signal, which is the unbalance.

Step two: take the envelope. The Hilbert transform gives a second signal in which every frequency component is shifted by a quarter of a cycle. The two together form the analytic signal, and its magnitude is the envelope:

The envelope

For a sine the shifted signal is , so at every instant: the envelope of a steady sine is its amplitude. scipy.signal.hilbert returns directly, so the envelope is np.abs(hilbert(x)).

Step three: remove the mean. The envelope is never negative, so it has a large average value. That average would be a large line at 0 Hz that leaks into the low frequencies. Subtract it.

Step four: take the spectrum of the envelope. With a Hann window and samples, the amplitude of each line is

where is the FFT of the windowed signal and is the mean of the window (0.5 for a Hann window). The result is the envelope spectrum. Its frequency axis is the rate of repetition, not the frequency of the ringing.

Why the envelope spectrum has multiples

The envelope of a burst rises almost at once and then decays. A sharp-edged shape repeating at 74 Hz is not a sine, so its spectrum has lines at 74 Hz and at 2, 3, 4 and more times 74 Hz. This row of multiples is the usual picture of a defect in an envelope spectrum, and it also separates a bearing frequency from a nearby multiple of running speed, as Application 1 shows.

Choosing the band

The correct band is the one that holds the ringing. There are two practical ways to find it.

  • Look at the ordinary acceleration spectrum on a logarithmic amplitude axis, up to the highest frequency the sensor allows. A hump of raised level, some hundreds of hertz wide, marks a resonance that something is exciting.
  • Compare with a reading from the same point when the bearing was known to be healthy. The band where the level has risen most is the band to use.

Make the band wide enough to pass several sidebands on each side of the centre: a band that passes only one line gives a steady sine with a flat envelope. Keep the band clear of strong steady lines such as gear mesh frequency, because two steady lines beat at their difference frequency and give a false line.

Outer race against inner race

In a horizontal motor the rotor weight is carried by the lower part of the bearing, the load zone. An outer-race defect does not move; if it lies in the load zone, every ball strikes it with about the same force.

An inner-race defect turns with the shaft: once per turn through the load zone, where the impacts are strong, then through the unloaded top, where they are weak. The impact size rises and falls once per shaft turn: a second modulation, at running speed. In the envelope spectrum it gives sidebands at on each side of the fault frequency, and a line at itself.

Application 1: An outer-race defect on machine A



Step 1: Read the ordinary spectrum

Click to reveal the ordinary spectrum
  1. Largest line. The largest line in the whole spectrum is at 24.5 Hz with an amplitude of . This is running speed (24.42 Hz, read on a 0.5 Hz grid). ✅

  2. Line at the fault frequency. At 74.0 Hz the amplitude is .

    On a real machine a line of this size is lost. Note that 3 times running speed is 73.25 Hz, less than 1 Hz away. ✅

  3. The hump. Between 2,000 and 4,500 Hz the largest lines are at 3,128.0, 3,202.0, 3,053.5 and 3,257.5 Hz, each about . The differences and are the fault frequency. The repetition is in the spacing of the fine lines. ✅

  4. Compare with a healthy reading. The same generator with no impacts gives an RMS level of in the band from 2,400 to 4,000 Hz. With the impacts it is , almost 3 times higher. This rise is how the band is found in practice. ✅

Step 2: Filter and take the envelope

Click to reveal the filter and the envelope
  1. Design the filter. A 4th-order Butterworth band-pass from 2,400 to 4,000 Hz, as second-order sections:

    sos = signal.butter(4, [2400, 4000], btype="bandpass", fs=25600, output="sos") ✅

  2. Apply it forwards and backwards. y = signal.sosfiltfilt(sos, a) runs the filter in both directions, so the bursts are not shifted in time. The running speed line is far below the band and is removed. ✅

  3. Envelope. env = np.abs(signal.hilbert(y)) is the magnitude of the analytic signal. ✅

  4. Remove the mean. env = env - env.mean() takes away the line at 0 Hz. ✅

Step 3: Read the envelope spectrum and match it

Click to reveal the envelope spectrum
  1. Largest lines. The six largest lines below 500 Hz are:

    Line (Hz)Amplitude ()Line / 74.15
    74.00.10971.00
    148.50.10042.00
    222.50.07843.00
    297.00.05664.01
    371.00.05115.00
    445.00.03796.00

    The median level of the envelope spectrum from 10 to 500 Hz is , so the first line stands about 60 times above it. ✅

  2. Match with the bearing frequencies. The lines are multiples of 74.15 Hz, the outer-race frequency BPFO. They do not match BPFI (121.19 Hz), BSF (47.75 Hz) or FTF (9.27 Hz). ✅

  3. Exclude running speed. The first line, 74.0 Hz, is only 0.75 Hz from 3 times running speed (73.25 Hz), and the resolution is 0.5 Hz, so the first line alone does not decide. The higher lines do. The fourth line is at 297.0 Hz. Four times BPFO is 296.6 Hz, and 12 times running speed is 293.0 Hz, which is 8 resolution steps away. The sixth line, 445.0 Hz, lies on 6 times BPFO (444.9 Hz) and not on 18 times running speed (439.5 Hz). The row is not a multiple of running speed. ✅

  4. Diagnosis. The envelope spectrum is consistent with a defect on the outer race of the drive-end bearing. ✅

Step 4: The wrong band, and a check by a second method

Click to reveal the wrong band and the check
  1. Band of 500 to 1,500 Hz. The same steps with this band give a line at 74.0 Hz of only , which is 13.4 times smaller than in the correct band. ✅

  2. Why it is weak, not zero. A sharp burst spreads a little energy over all frequencies. In this clean generated signal the weak line can still be seen. On a real machine this band also holds multiples of running speed and other machine lines, and a line this small is lost among them. ✅

  3. Check by autocorrelation. The autocorrelation shows at what time shift a signal repeats itself, with no spectrum. For the envelope from the correct band, the strongest repeat between 5 and 20 ms is at 13.48 ms.

    This agrees with the 74.0 Hz line and with the impact rate the generator used. ✅

Application 2: An inner-race defect with modulation at running speed



Step 1: Predict the pattern

Click to reveal the prediction
  1. Fault frequency and its second multiple. and . ✅

  2. Sidebands. The size of the impacts changes at , so each of these lines has a sideband on each side at a distance of :

    These are the expected sideband frequencies. ✅

  3. Line at running speed. The average height of the envelope also rises and falls once per turn, so a line is expected at . It comes from the modulation: the filter has already removed the running speed component of the acceleration itself. ✅

Step 2: Read the envelope spectrum

Click to reveal the lines found
  1. Lines found.

    LineExpected (Hz)Found (Hz)Amplitude ()
    24.4224.50.0997
    96.7797.00.0800
    121.19121.00.1703
    145.60145.50.0743
    217.96218.00.0613
    242.37242.50.1194
    266.79267.00.0424

    Every expected line is found within one resolution step of 0.5 Hz. ✅

  2. Sideband spacing. and . The mean, 24.25 Hz, is running speed within the resolution. ✅

  3. Diagnosis. A line at 4.96 orders with sidebands at running speed and a line at running speed is consistent with a defect on the inner race, which turns with the shaft through the load zone. ✅

Step 3: Check by removing the modulation

Click to reveal the limiting case
  1. Set the depth to zero. Run the extended generator with the factor 0.8 replaced by 0, so that all impacts are equal. ✅

  2. Result. The line at BPFI stays at . The line at running speed falls from 0.0997 to , and the lower sideband falls from 0.0800 to . Both are now at the level of the background. ✅

  3. Conclusion. The sidebands and the running speed line are caused by the change in impact size and by nothing else. ✅

m/s²0.170.100.080Hz24.597.0 121.0 145.51×1×1×BPFI
Envelope spectrum of the inner-race signal

Limits of the method



Low speed. The force of each impact falls quickly as the speed falls, and a soft impact may not make the housing ring at all. The fault frequency is also low, so a long record is needed to hold enough impacts. At 100 rev/min the BPFO of this bearing is about 5 Hz, and a 2 s record holds 10 impacts where it held 148.

Noise. The script raises the noise in the generated signal in steps. The fault line falls and the background rises:

Noise RMS ()Fault line ()Median background ()Ratio
0.150.10970.001862.5
0.500.07040.004117.0
1.000.04180.00765.5
1.500.03160.01102.9
2.000.02680.01471.8

At a noise of RMS, ten times the starting value, the line is under 3 times the background and could not be reported with confidence. At a random line at 68.5 Hz is larger than the fault line: the fault line is lost. These levels belong to this signal and this seed. Averaging the envelope spectra of several records smooths the background and moves the limit.

Sensor bandwidth and mounting. The method reads a resonance at some thousands of hertz, so the whole chain must pass them: an accelerometer with a flat response beyond the band, and a stiff mounting (a stud or good adhesive on a clean flat surface). A weak magnet on paint, or a hand-held probe, typically loses the high frequencies. The band of Application 1, 2,400 to 4,000 Hz, is above the typical limit of a two-pole magnet (about 2 to 3 kHz), so it needs a stud, an adhesive pad or a flat magnet on a prepared pad. A loose mounting can also add a resonance of its own inside the band; the “hump” then moves each time the magnet is placed, which is a sign to fix the mounting, not to move the band. The sampling rate must be more than twice the top of the band, and 2.56 times is the usual figure, so a band to 4,000 Hz needs at least 10,240 samples per second.

Low-cost sensors. A low-cost accelerometer sampling at a few hundred hertz cannot do this: at 400 samples per second the highest frequency is 200 Hz, and the ringing at 3,200 Hz is out of range. It is useful for trending and the lower frequencies; envelope analysis needs an industrial accelerometer, stiffly mounted and sampled fast.

Verify It in Python



The script copies the course generator, adds the inner-race version with its one changed line, and produces every number of this lesson. It saves one plot with four panels.

envelope_analysis_bearing.py
"""Envelope analysis of a generated bearing signal: outer-race and inner-race faults."""
import numpy as np
from scipy import signal
import matplotlib.pyplot as plt
def bearing_signal(fs=25600, seconds=2.0, fault_hz=74.2, resonance_hz=3200.0,
decay=900.0, impact=1.0, noise=0.15, fr=24.42, seed=9):
"""Acceleration in m/s². A decaying resonance burst at each fault impact."""
rng = np.random.default_rng(seed)
n = int(fs * seconds); t = np.arange(n) / fs; a = np.zeros(n)
period = 1.0 / fault_hz
k = 0
while k * period < seconds:
t0 = k * period + period * rng.normal(0.0, 0.01) # small random slip of each impact
i0 = int(t0 * fs)
if i0 < n:
tt = t[i0:] - t[i0]
a[i0:] += impact * np.exp(-decay * tt) * np.sin(2 * np.pi * resonance_hz * tt)
k += 1
a += 0.4 * np.sin(2 * np.pi * fr * t) # running speed component
return t, a + rng.normal(0.0, noise, n)
def inner_race_signal(fs=25600, seconds=2.0, fault_hz=121.19, resonance_hz=3200.0,
decay=900.0, impact=1.0, noise=0.15, fr=24.42, seed=9, depth=0.8):
"""The same generator with ONE change: each impact is multiplied by
1 + depth*cos(2*pi*fr*t0), because the defect turns through the load zone."""
rng = np.random.default_rng(seed)
n = int(fs * seconds); t = np.arange(n) / fs; a = np.zeros(n)
period = 1.0 / fault_hz
k = 0
while k * period < seconds:
t0 = k * period + period * rng.normal(0.0, 0.01)
i0 = int(t0 * fs)
if i0 < n:
tt = t[i0:] - t[i0]
size = impact * (1.0 + depth * np.cos(2 * np.pi * fr * t0)) # the change
a[i0:] += size * np.exp(-decay * tt) * np.sin(2 * np.pi * resonance_hz * tt)
k += 1
a += 0.4 * np.sin(2 * np.pi * fr * t)
return t, a + rng.normal(0.0, noise, n)
def spectrum(x, fs):
"""Amplitude spectrum with a Hann window: amplitude = 2|X| / (n * mean of window)."""
n = len(x)
w = signal.windows.hann(n, sym=False)
return np.fft.rfftfreq(n, 1.0 / fs), 2.0 * np.abs(np.fft.rfft(x * w)) / (n * w.mean())
def envelope(x, fs, low, high):
"""Band-pass (4th-order Butterworth, zero phase), then magnitude of the analytic signal."""
sos = signal.butter(4, [low, high], btype="bandpass", fs=fs, output="sos")
return np.abs(signal.hilbert(signal.sosfiltfilt(sos, x)))
def envelope_spectrum(x, fs, low, high):
env = envelope(x, fs, low, high)
return spectrum(env - env.mean(), fs)
def line_near(f, amp, f0, tol=1.0):
"""Largest line within tol of f0: returns (frequency, amplitude)."""
m = (f >= f0 - tol) & (f <= f0 + tol)
i = np.argmax(amp[m])
return f[m][i], amp[m][i]
def largest_lines(f, amp, f_low, f_high, count):
m = (f >= f_low) & (f <= f_high)
idx, _ = signal.find_peaks(amp[m])
idx = idx[np.argsort(amp[m][idx])[::-1][:count]]
return [(f[m][i], amp[m][i]) for i in idx]
def band_rms(f, amp, f_low, f_high):
"""RMS of the part of the signal between two frequencies, from the Hann spectrum."""
m = (f >= f_low) & (f <= f_high)
return np.sqrt(np.sum(amp[m] ** 2) / 2.0 / 1.5) # 1.5 = noise bandwidth of Hann
# ---------- Bearing 6309 on machine A ----------
N_BALLS, BALL_D, PITCH_D = 8, 17.46, 72.5 # typical catalogue geometry, mm
FR = 1465.0 / 60.0
RATIO = BALL_D / PITCH_D
BPFO = N_BALLS / 2 * FR * (1 - RATIO)
BPFI = N_BALLS / 2 * FR * (1 + RATIO)
BSF = PITCH_D / (2 * BALL_D) * FR * (1 - RATIO ** 2)
FTF = FR / 2 * (1 - RATIO)
print("Bearing 6309 at 1465 rev/min")
print(f" 1x {FR:.2f} Hz, BPFO {BPFO:.2f} Hz ({BPFO / FR:.2f} orders), "
f"BPFI {BPFI:.2f} Hz ({BPFI / FR:.2f} orders)")
print(f" BSF {BSF:.2f} Hz, FTF {FTF:.2f} Hz")
FS = 25600
BAND = (2400.0, 4000.0)
# ---------- Application 1: outer-race signal ----------
t, a = bearing_signal()
f, A = spectrum(a, FS)
print(f"Record: {len(a)} samples, {len(a) / FS:.1f} s, resolution {FS / len(a):.2f} Hz")
f1, a1 = line_near(f, A, FR)
ff, af = line_near(f, A, 74.2)
print("Ordinary spectrum")
print(f" largest line: {f1:.1f} Hz, {a1:.3f} m/s2")
print(f" line at the fault frequency: {ff:.1f} Hz, {af:.4f} m/s2 "
f"({100 * af / a1:.1f} % of the largest)")
hump = largest_lines(f, A, 2000, 4500, 4)
print(" largest lines 2000 to 4500 Hz: "
+ ", ".join(f"{x:.1f} Hz ({y:.4f})" for x, y in hump))
_, a_ok = bearing_signal(impact=0.0)
f_ok, A_ok = spectrum(a_ok, FS)
print(f" RMS in 2400 to 4000 Hz: faulty {band_rms(f, A, *BAND):.3f} m/s2, "
f"healthy {band_rms(f_ok, A_ok, *BAND):.3f} m/s2")
fe, E = envelope_spectrum(a, FS, *BAND)
print("Envelope spectrum, band 2400 to 4000 Hz")
for x, y in sorted(largest_lines(fe, E, 5, 500, 6)):
print(f" {x:6.1f} Hz {y:.4f} m/s2 = {x / BPFO:.2f} x BPFO")
floor = np.median(E[(fe >= 10) & (fe <= 500)])
print(f" median level 10 to 500 Hz: {floor:.4f} m/s2")
fw, W = envelope_spectrum(a, FS, 500.0, 1500.0)
xw, yw = line_near(fw, W, 74.2)
print(f"Wrong band 500 to 1500 Hz: line at {xw:.1f} Hz is {yw:.4f} m/s2, "
f"{line_near(fe, E, 74.2)[1] / yw:.1f} times smaller than in the right band")
env = envelope(a, FS, *BAND)
e0 = env - env.mean()
ac = signal.correlate(e0, e0, mode="full", method="fft")[len(e0) - 1:]
lo, hi = int(0.005 * FS), int(0.020 * FS)
lag = (lo + np.argmax(ac[lo:hi])) / FS
print(f"Check by autocorrelation: repeat time {1000 * lag:.2f} ms = {1 / lag:.1f} Hz")
print("Noise test (band 2400 to 4000 Hz)")
for noise in (0.15, 0.5, 1.0, 1.5, 2.0):
_, an = bearing_signal(noise=noise)
fn, En = envelope_spectrum(an, FS, *BAND)
xn, yn = line_near(fn, En, 74.2)
med = np.median(En[(fn >= 10) & (fn <= 500)])
m = (fn >= 50) & (fn <= 100)
top = fn[m][np.argmax(En[m])]
print(f" noise {noise:.2f} m/s2: fault line {yn:.4f}, median {med:.4f}, "
f"ratio {yn / med:.1f}, largest line 50 to 100 Hz at {top:.1f} Hz")
# ---------- Application 2: inner-race signal ----------
t2, a2 = inner_race_signal(fault_hz=BPFI, fr=FR)
fi, E2 = envelope_spectrum(a2, FS, *BAND)
print("Inner-race signal, envelope spectrum")
for name, f0 in (("1x", FR), ("BPFI - 1x", BPFI - FR), ("BPFI", BPFI),
("BPFI + 1x", BPFI + FR), ("2 BPFI - 1x", 2 * BPFI - FR),
("2 BPFI", 2 * BPFI), ("2 BPFI + 1x", 2 * BPFI + FR)):
x, y = line_near(fi, E2, f0)
print(f" {name:<12} expected {f0:6.2f} Hz, found {x:6.1f} Hz, {y:.4f} m/s2")
_, a3 = inner_race_signal(fault_hz=BPFI, fr=FR, depth=0.0)
f3, E3 = envelope_spectrum(a3, FS, *BAND)
print(" with no modulation: 1x line "
f"{line_near(f3, E3, FR)[1]:.4f}, BPFI - 1x {line_near(f3, E3, BPFI - FR)[1]:.4f}, "
f"BPFI {line_near(f3, E3, BPFI)[1]:.4f} m/s2")
# ---------- Plot ----------
fig, ax = plt.subplots(4, 1, figsize=(9, 11))
ax[0].plot(1000 * t[:2560], a[:2560], linewidth=0.6, label="acceleration")
ax[0].plot(1000 * t[:2560], env[:2560], linewidth=1.2, label="envelope of the band")
ax[0].set_xlabel("time (ms)"); ax[0].set_ylabel("m/s2")
ax[0].set_title("Outer-race signal, first 100 ms"); ax[0].legend()
ax[1].semilogy(f, A, linewidth=0.6)
ax[1].axvspan(*BAND, alpha=0.15)
ax[1].set_xlim(0, 6000); ax[1].set_ylim(1e-4, 1)
ax[1].set_xlabel("frequency (Hz)"); ax[1].set_ylabel("m/s2")
ax[1].set_title("Ordinary spectrum (shaded: the band chosen)")
ax[2].plot(fe, E, linewidth=0.8)
for k in range(1, 5):
ax[2].axvline(k * BPFO, linestyle=":", linewidth=0.8)
ax[2].set_xlim(0, 400); ax[2].set_xlabel("frequency (Hz)"); ax[2].set_ylabel("m/s2")
ax[2].set_title("Envelope spectrum, outer race (dotted: multiples of BPFO)")
ax[3].plot(fi, E2, linewidth=0.8)
for f0 in (FR, BPFI - FR, BPFI, BPFI + FR):
ax[3].axvline(f0, linestyle=":", linewidth=0.8)
ax[3].set_xlim(0, 400); ax[3].set_xlabel("frequency (Hz)"); ax[3].set_ylabel("m/s2")
ax[3].set_title("Envelope spectrum, inner race (dotted: 1x, BPFI and its sidebands)")
fig.tight_layout()
fig.savefig("envelope_analysis_bearing.png", dpi=120)
print("Saved envelope_analysis_bearing.png")

Expected output

Bearing 6309 at 1465 rev/min
1x 24.42 Hz, BPFO 74.15 Hz (3.04 orders), BPFI 121.19 Hz (4.96 orders)
BSF 47.75 Hz, FTF 9.27 Hz
Record: 51200 samples, 2.0 s, resolution 0.50 Hz
Ordinary spectrum
largest line: 24.5 Hz, 0.394 m/s2
line at the fault frequency: 74.0 Hz, 0.0063 m/s2 (1.6 % of the largest)
largest lines 2000 to 4500 Hz: 3128.0 Hz (0.0213), 3202.0 Hz (0.0204), 3053.5 Hz (0.0175), 3257.5 Hz (0.0170)
RMS in 2400 to 4000 Hz: faulty 0.144 m/s2, healthy 0.052 m/s2
Envelope spectrum, band 2400 to 4000 Hz
74.0 Hz 0.1097 m/s2 = 1.00 x BPFO
148.5 Hz 0.1004 m/s2 = 2.00 x BPFO
222.5 Hz 0.0784 m/s2 = 3.00 x BPFO
297.0 Hz 0.0566 m/s2 = 4.01 x BPFO
371.0 Hz 0.0511 m/s2 = 5.00 x BPFO
445.0 Hz 0.0379 m/s2 = 6.00 x BPFO
median level 10 to 500 Hz: 0.0018 m/s2
Wrong band 500 to 1500 Hz: line at 74.0 Hz is 0.0082 m/s2, 13.4 times smaller than in the right band
Check by autocorrelation: repeat time 13.48 ms = 74.2 Hz
Noise test (band 2400 to 4000 Hz)
noise 0.15 m/s2: fault line 0.1097, median 0.0018, ratio 62.5, largest line 50 to 100 Hz at 74.0 Hz
noise 0.50 m/s2: fault line 0.0704, median 0.0041, ratio 17.0, largest line 50 to 100 Hz at 74.0 Hz
noise 1.00 m/s2: fault line 0.0418, median 0.0076, ratio 5.5, largest line 50 to 100 Hz at 74.5 Hz
noise 1.50 m/s2: fault line 0.0316, median 0.0110, ratio 2.9, largest line 50 to 100 Hz at 74.5 Hz
noise 2.00 m/s2: fault line 0.0268, median 0.0147, ratio 1.8, largest line 50 to 100 Hz at 68.5 Hz
Inner-race signal, envelope spectrum
1x expected 24.42 Hz, found 24.5 Hz, 0.0997 m/s2
BPFI - 1x expected 96.77 Hz, found 97.0 Hz, 0.0800 m/s2
BPFI expected 121.19 Hz, found 121.0 Hz, 0.1703 m/s2
BPFI + 1x expected 145.60 Hz, found 145.5 Hz, 0.0743 m/s2
2 BPFI - 1x expected 217.96 Hz, found 218.0 Hz, 0.0613 m/s2
2 BPFI expected 242.37 Hz, found 242.5 Hz, 0.1194 m/s2
2 BPFI + 1x expected 266.79 Hz, found 267.0 Hz, 0.0424 m/s2
with no modulation: 1x line 0.0030, BPFI - 1x 0.0022, BPFI 0.1690 m/s2
Saved envelope_analysis_bearing.png

Common Mistakes



  • Reporting a bearing as healthy because its fault frequency is absent from the ordinary velocity spectrum. Early defects do not show there.
  • Choosing the envelope band from a menu without looking for the resonance. Find the hump in the acceleration spectrum, or the band that has risen against the healthy reading, and filter there.
  • Forgetting to remove the mean of the envelope. The large line at 0 Hz then leaks into the low frequencies and hides slow lines such as the cage frequency.
  • Reading envelope amplitudes as severity. They depend on the band, the resonance and the mounting. Compare only with earlier readings at the same point and settings. Many instruments report the envelope in “gE”, a unit whose value depends on each maker’s filters, so gE from two makes of instrument cannot be compared.
  • Calling a single line near a bearing frequency a bearing defect. Check the multiples. A row that stays on multiples of BPFO and moves away from multiples of running speed is the evidence.

Summary



  • A bearing defect gives short bursts of ringing at a structural resonance. The fault frequency is the rate at which the bursts repeat, so the ordinary spectrum shows a hump with fine sidebands near the resonance and almost no line at the fault frequency (1.6 percent of the running speed line in our signal).
  • Envelope analysis has four steps: band-pass filter round the resonance, take the magnitude of the analytic signal, remove the mean, and take the spectrum.
  • For the outer-race signal the envelope spectrum showed lines at 74.0, 148.5, 222.5 and 297.0 Hz, multiples of BPFO, 60 times above the background.
  • For the inner-race signal it showed BPFI at 121.0 Hz with sidebands at 97.0 and 145.5 Hz and a line at 24.5 Hz, because the defect turns through the load zone once per shaft turn.
  • A band that missed the resonance made the fault line 13.4 times smaller. The method also needs speed, a signal above the noise, and a sensor chain that passes some thousands of hertz.

Exercises



1. A fan shaft turns at 1170 rev/min on a 6309 bearing (BPFO 3.04 orders, BPFI 4.96 orders). The envelope spectrum has lines at 59.3, 118.6 and 177.9 Hz and no sidebands. Which fault is this consistent with?

Answer

. The first line is orders, and the others are 2 and 3 times it. BPFO is . The row is consistent with an outer-race defect.

2. For machine A, BPFO is 74.15 Hz and 3 times running speed is 73.25 Hz. Using the working rule that two lines need at least 4 resolution steps between them with a Hann window, find the record length that separates them. How many steps apart are they in the 2 s record?

Answer

The spacing is . The resolution must be , so . In a 2 s record the resolution is 0.5 Hz and the lines are only 1.8 steps apart, which is why Application 1 used the higher multiples.

3. The same 6309 bearing runs slowly at 100 rev/min. Find BPFO, the number of outer-race impacts in a 2 s record, and the record length that holds 148 impacts, as the 2 s record did at 1465 rev/min.

Answer

and BPFO is . A 2 s record holds about 10 impacts. For 148 impacts, .

4. The 6309 bearing is used on pump B at 2900 rev/min (48.33 Hz), which has 6 impeller vanes. Find BPFI and its two sidebands at running speed. Which sideband lies close to the vane pass frequency, and what record length separates the two by 4 resolution steps?

Answer

BPFI is , with sidebands at and . Vane pass is , only 1.77 Hz from the upper sideband. The resolution must be , so .

References



  • R. B. Randall, Vibration-based Condition Monitoring: Industrial, Automotive and Aerospace Applications, 2nd edition, Wiley, 2021.
  • R. B. Randall and J. Antoni, “Rolling element bearing diagnostics: a tutorial”, Mechanical Systems and Signal Processing, vol. 25, no. 2, 2011.
  • C. Scheffer and P. Girdhar, Practical Machinery Vibration Analysis and Predictive Maintenance, Elsevier Newnes, 2004.


© 2021-2026 SiliconWit®. All rights reserved.
defect: impact at each ball pass 74.15 per second inner race turns at 24.42 Hz outer race balls sharp force Bearing housing (a resonance) rings near 3,200 Hz Accelerometer to the analyser
From the defect to the sensor
Impacts Signal Envelope 13.5 ms ringing at 3,200 Hz in each burst repeats 74 times a second 0 10 ms 20 ms 30 ms 40 ms
Impacts, bursts and the envelope
a(t) Band-pass filter Envelope (Hilbert) Remove mean Spectrum (FFT) envelope spectrum step 1 step 2 step 3 step 4
Envelope analysis in four steps
Hz m/s² 0.05 0.10 0.15 0.100 24.5 0.080 97.0 0.170 121.0 0.074 145.5 BPFI 1× 1× 1× sidebands at 1× = 24.42 Hz each side of BPFI
Envelope spectrum of the inner-race signal
Predict first

A pit on the outer race of a bearing is struck 74 times each second. Each blow is short and sharp, and it makes the bearing housing ring at about 3200 Hz for a few milliseconds. Where does an ordinary spectrum of this signal show most of its energy?

Watch it build: from the ringing to the repetition
13.49 ms a burst of ringing at each impact 74 Hz: almost nothing 0 3200 Hz carrier: the 3200 Hz ringing message: the impacts the envelope E(t) 74 148 222 297 Hz envelope spectrum
  1. Each impact makes a burst of ringing at about 3200 Hz, one burst every 13.49 ms.
  2. The ordinary spectrum puts the energy in a hump near 3200 Hz and almost nothing at 74 Hz.
  3. As in radio: the 3200 Hz ringing is the carrier, and the train of impacts is the message.
  4. The envelope E(t) follows the outline. Its spectrum has lines at 74.15 Hz and its multiples.
See it: from impacts in noise to a line at the fault frequency

Impacts
Filter band
Largest line, 5 to 500 Hz
Line at the fault frequency
Median level, 10 to 500 Hz
Lines at 2, 3 and 4 times
Filter band

Read the panels from the top. The first is what the accelerometer gives: a burst of ringing at each impact, on the slow wave of running speed, with noise. The second is the same signal after a band-pass filter 1600 Hz wide: the slow wave and most of the noise are gone. The third is the envelope, the outline of the ringing, and it repeats at the rate of the impacts. The fourth is the spectrum of the envelope with its mean removed. The dotted lines mark the fault frequency you chose and its multiples, and the ring marks the largest line. The lines are 0.5 Hz apart, so a line can sit up to 0.25 Hz from the true frequency. Raise the noise and watch the row of lines sink into the background. Choose the band from 500 to 1500 Hz, which misses the resonance, and see what is left. The signal has the same form as the lesson's generator, with the same sampling rate, record length, decay and running speed component, but its random numbers are this figure's own. Its values are therefore close to the lesson's and not identical. They belong to this one signal.

Check yourself

Three questions. Each wrong choice is a mistake people really make, so read the note after you answer.

1. The housing of a bearing rings at 3200 Hz. An analyst selects a fixed envelope band of 500 to 1500 Hz from the menu, and the envelope spectrum is nearly empty. What does this result show?

2. The envelope of a band from 2400 to 4000 Hz is needed. With the usual factor of 2.56, what is the lowest sampling rate?

3. A motor runs at 24.42 Hz. The envelope spectrum of its drive-end bearing, a 6309, has its largest line at 121.0 Hz, with smaller lines at 97.0 Hz and 145.5 Hz and a line at 24.5 Hz. What is this pattern consistent with?

carrier: the ringing, about 3200 Hz message: the outline, 74.15 per second
outer raceinner race all equalonce a turn turn 1turn 2 74.15 per second, steady | 121.19 per second, rising and falling at 24.42 Hz