An owner pays for a ten kilowatt array, looks at the inverter at noon on a bright day, and reads six. A workshop that was promised “enough solar for the whole load” runs its generator every afternoon of the rainy season. In both cases the equipment may be healthy. The fault is in the expectation: nobody counted how much light reaches that roof, hour by hour and month by month. This lesson shows how to count it, in the two units that every solar calculation uses. #SolarResource #PeakSunHours #Irradiance

Learning Objectives

By the end of this lesson, you will be able to:

  1. Distinguish irradiance from insolation and convert a day of irradiance readings into peak sun hours
  2. Explain what the air and the clouds do to sunlight, in terms of air mass, direct light and diffuse light
  3. Calculate the position of the noon sun for a latitude and a date, and the effect of a roof tilt on the light received
  4. Estimate the daily energy of an array from its nameplate power, the peak sun hours and a performance ratio
  5. Size on the worst month and show the shortfall that comes from sizing on the yearly mean

Real-World System Problem: A workshop roof near the equator



This course follows one site: a workshop and office near the equator, at latitude 1° south. Its roof, tilted 10° and facing north, carries 18 modules of 550 W, which is 9.9 kW of nameplate power, written 9.9 kWp (“kilowatt peak”). A hybrid inverter of 8 kW feeds the load of 30 kWh a day, charges a battery of 15.36 kWh, and can take power from an unreliable grid or a standby generator.

The owner asks two questions: how much energy will the roof give in a day, and will it be enough in every month? The module’s label cannot answer. It gives the output under one fixed test light, while the answer depends on the light that really arrives at this place, in this season and weather: the solar resource.

Every later calculation of the course starts from it. If the resource is wrong, the array, the battery and the generator hours are all wrong with it.

Battery15.4 kWhGrid andgeneratorLoad30 kWha dayHybrid inverter 8 kWArray 9.9 kWp18 modules, tilt 10°sun (irradiance G, W/m²)
The site: everything starts from the light on the roof

Fundamental Theory: Light as power and light as energy



Irradiance: the power of the light

Irradiance is the power of the sunlight that falls on one square metre of a surface. Its symbol in this course is and its unit is the watt per square metre, W/m². It is a value of the moment. It changes with the hour, and it can halve in ten seconds when a cloud passes.

Remember two values: about 1,360 W/m² above the atmosphere on a surface facing the sun, and close to 1,000 W/m² on the ground with a clear sky and a high sun. The rounded 1,000 W/m² is the reference light for testing modules. A module’s nameplate power is its output at standard test conditions (STC): an irradiance of 1,000 W/m², a cell temperature of 25 °C and a defined spectrum of light called air mass 1.5.

The irradiance that matters to an array is measured in the plane of the modules, with the sensor tilted and turned exactly as they are: the plane-of-array irradiance. Weather stations and most databases give the irradiance on a horizontal surface, a different number.

Insolation: the energy of a day

The energy that falls on one square metre in a day is the insolation, symbol . Think of rain: irradiance is how hard it falls now, and insolation is the water in the bucket by evening (but sunlight not used when it falls is gone). is the area under the day’s curve of irradiance against time:

With in W/m² and time in hours, the result is in Wh/m². Dividing by 1,000 gives kWh/m², the usual unit. (Some texts use the name irradiation for the same quantity.)

In practice a sensor gives readings at equal steps of time, and the area is their sum multiplied by the step:

Twelve readings on the hour, added, give Wh/m² directly, because each stands for one hour.

Peak sun hours

An insolation of 5.5 kWh/m² is the same energy as a steady 1,000 W/m² for 5.5 hours: 5.5 peak sun hours. Squeeze the day’s curve into a block 1,000 W/m² high with the same area, and the width of the block is the peak sun hours. The number equals in kWh/m²; only the picture differs.

W/m²10005.5 hourssame area:917,.5.5 kWh/m²,'`.500/\/\0.'`.06:3012:3018:30
One day as a curve, and as 5.5 hours of full sun

They are useful because nameplate power is defined at exactly 1,000 W/m², so a perfect array of kilowatts would give kWh for every peak sun hour. A real system gives less; the ratio of real to perfect is the performance ratio, .

Daily energy from the resource

is the energy at the inverter output in kWh, the nameplate power of the array in kWp, the plane-of-array insolation in kWh/m² (peak sun hours), and the performance ratio, a number below 1 that collects every loss between the light and the output.

What the air does: air mass, direct light and diffuse light

Sunlight loses power crossing the atmosphere: gas molecules, water vapour and dust absorb part of it and scatter another part in all directions. The longer the path through the air, the greater the loss.

Air mass is the length of that path compared with the shortest one, straight down. With the sun directly overhead it is 1; a lower sun sends the light through the air at a slant, and the air mass is larger. For a sun that is at an angle from overhead (the zenith angle), a good approximation for angles up to about 70° is

A sun 48.2° from overhead gives 1.5, the value of the standard test spectrum; 60° gives 2, twice as much air. This is one reason the light at 08:00 is weaker than at noon, even under a clear sky. The other is the angle at which the light meets the surface, treated below.

The light that reaches a module has two parts.

  • Direct light (also called beam light) comes in a straight line from the sun. It makes sharp shadows, and its strength on a surface depends strongly on the angle at which it arrives.
  • Diffuse light has been scattered by the air and the clouds and comes from the whole sky. It makes no sharp shadow.
cloudmodulesundirectdiffuse
Direct and diffuse light on a module

On a clear day the diffuse part is roughly one tenth to one fifth of the light; under full cloud almost all of it is diffuse. A module uses both. So an array still produces under a grey sky, typically at a small fraction of its clear-sky power, and a shadow from a pole removes the direct part but not the diffuse part.

The path of the sun near the equator

The axis of the earth is tilted, so through the year the sun appears to move north and south. The angle of the sun north or south of the equator is the declination, . It is on 21 June, on 21 December, and zero at the two equinoxes in March and September. A formula that is accurate enough for this work (Cooper’s equation, with the day number of the year) is

At solar noon the sun is on the north-south line. Its angle from overhead is the difference between the latitude and the declination:

with north positive and south negative for both angles. If is greater than , the noon sun is to the north of overhead. If it is smaller, the sun is to the south.

For the site at the values are in the table (from the script at the end of the lesson).

DateDeclinationNoon sunAir mass at noon
21 March0.60° from overhead, to the north1.00
21 June24.45° from overhead, to the north1.10
22 September0.39° from overhead, to the north1.00
21 December22.45° from overhead, to the south1.08

Near the equator three things follow. The noon sun is always high, never more than about 24° from overhead. It is to the north for half the year and to the south for the other half. And the day is close to 12 hours long in every month. Far from the equator the winter sun is low and the days are short; near it the geometry changes little, and cloud decides the season.

Tilt and direction

Direct light delivers its full power only to a surface that faces it. If the light arrives at an angle from the perpendicular of the surface (the angle of incidence), the power on the surface is reduced by the cosine:

At 10° from the perpendicular the factor is 0.985, a loss of 1.5 percent. At 30° it is 0.866. At 60° it is 0.5. The cosine is flat near zero, so small errors of angle cost little, and large ones cost a lot.

roof faces northNORTHSOUTHJuneDecember24° from22° fromoverheadoverheadoverheadtilt 10°
The noon sun over a roof tilted 10° to the north

The site’s roof is tilted 10° towards the north. In June the noon sun is 24.45° to the north, from the perpendicular of the roof: a cosine factor of 0.968, against 0.910 for a flat roof. In December the sun is 22.45° to the south, from the perpendicular: 0.844 against 0.924 flat. The tilt helps in the middle of the year and costs at the end of it; over a year the two nearly cancel.

These factors are for the direct light at noon only; a yearly figure for a tilted surface comes from a database or a tool that repeats this for every hour. Such tools confirm a simple rule: for the highest yearly energy, face the equator and tilt by about the latitude.

By that rule a roof at 1° south should be almost flat. It is not, for a reason that has nothing to do with the sun: a flat module holds water, dust settles in it, and when it dries a layer of dirt stays, thickest along the lower edge of the frame. A tilted module lets rain run off with the dust. Installers and module makers commonly ask for about 10° or more for this reason; the maker’s installation manual decides the value for a real module. At 10° the worst cosine cost is a few percent at one end of the year, and the rain washes the array without charge.

Seasons and the worst month

The insolation of a place is usually given as twelve monthly means, each in kWh/m² a day. For the site of this course the plane-of-array values are: a yearly mean of 5.5 peak sun hours, and 4.5 in the worst month.

The mean answers one question: how much energy in a year (multiply it by 365, the array and the performance ratio)? It cannot answer another: will the load be supplied every day? An array has no memory of the sunny months, and a battery carries energy from noon to midnight, not from January to July. A system that must carry its load in every month is sized on the worst month.

Inside a month the days are also unequal: a mean of 4.5 can hold days of 3.5 and of 5.5. The application below puts numbers on both effects.

Where real numbers come from

A real design uses real data for the real place. There are two kinds.

Measured data comes from an instrument at or near the site. A pyranometer measures the irradiance from the whole sky with a thermal sensor under a glass dome, and responds almost equally to all colours of sunlight. A reference cell is a small calibrated solar cell; it responds to light as a module does, so it is a good choice for judging an array, and it costs less. Both must be fitted in the plane of the array and kept clean, or they report the dirt on their own glass.

Satellite data comes from public and commercial databases that calculate the ground irradiance from satellite images of cloud and models of the atmosphere. They cover almost every place on earth over many years, with monthly means and often hourly values for a chosen tilt and direction. For a place with no measurements they are the normal source for a design.

Both have limits. A satellite value is an estimate for an area of several kilometres and can differ from a good ground measurement by several percent, more where cloud forms locally. A ground instrument is exact for its place, but only for the time it has recorded, and one year can differ from the next.

Application 1: From a day of irradiance to peak sun hours



Step 1: The clear day by the hourly sum

Click to reveal the calculation
  1. Add the readings. Each reading stands for one hour, so the sum is in Wh/m².

    ✅

  2. Convert. kWh/m². The clear day has 5.50 peak sun hours. ✅

  3. Compare with daylight. The light lasted 12 hours; the energy is that of 5.5 hours at 1,000 W/m². The ratio is 0.46: even with no cloud, less than half of the daylight hours count as peak sun hours. ✅

Step 2: The clear day from its shape

Click to reveal the calculation
  1. The mean of a sine squared. Over its full width, a sine-squared curve has a mean of exactly half its peak. So the insolation is half the peak multiplied by the length of the day. ✅

  2. Calculate.

    The two methods agree. ✅

  3. Where the energy is. In the 5-minute record the irradiance is above 800 W/m² for 2.75 hours and above 500 W/m² for 5.58 hours. The four hours from 10:00 to 14:00 hold 59.8 percent of the day’s energy. ✅

  4. What this means for the peak. Even on this clear day the irradiance never passes 916.7 W/m², so the array cannot show its nameplate power at any moment, before a single loss is counted. ✅

Step 3: The cloudy day

Click to reveal the calculation
  1. Add the hourly readings.

    The hourly sum gives 4.56 kWh/m². ✅

  2. Compare with the 5-minute record. The sum of all 5-minute readings, each multiplied by hour, is 4.388 kWh/m². The hourly sum is 3.9 percent too high. ✅

  3. Why they differ. The clear curve is smooth, so one reading describes its hour well. On the cloudy day the irradiance changes inside the hour: near midday it falls for a short time to 0.40 of the clear value, between two readings. Whether a reading lands in a gap or in a shadow is chance, so the error can have either sign. ✅

  4. The loss to cloud. : the cloud removed 20.2 percent of the day’s energy, yet the peak of 889.6 W/m² is almost the clear value. A look at the meter at the right moment would show nothing wrong. ✅

Step 4: Check in Python and with a heavier cloud

Click to reveal the check
  1. The script. The script at the end of the lesson sums the 5-minute record: 5.500 kWh/m² for the clear day and 4.388 kWh/m² for the cloudy day, the values used above. ✅

  2. A heavier day. With cloud=1.0 the generator gives a peak of 768.8 W/m² and 3.114 kWh/m², 56.6 percent of the clear day. Its hourly sum, 3.105 kWh/m², is only 0.3 percent off, in the other direction: same method, different day, different error. ✅

  3. A limiting case. A steady 1,000 W/m² for 5.5 hours is Wh/m², the same as the clear day. That is the definition of 5.5 peak sun hours. ✅

Application 2: The mean month and the worst month



Step 1: Daily and yearly energy of the site’s array

Click to reveal the calculation
  1. Mean day.

    This is 10.8 kWh more than the load. ✅

  2. Worst month.

    This is 3.4 kWh more than the load. ✅

  3. A year. kWh (with unrounded values), which is 1,506 kWh for each kWp of nameplate. The yearly mean is the right number for this question. ✅

Step 2: An array sized on the mean

Click to reveal the calculation
  1. Size. The array must give 30 kWh from 5.5 peak sun hours.

    That is 13.2 modules of 550 W. ✅

  2. Worst month. kWh a day. ✅

  3. Shortfall. kWh a day, 18.2 percent of the load. Over 30 days it is 164 kWh, which at 22 currency units per kWh costs 3,600 currency units from the grid. If the grid is down, it is generator fuel or load not served. ✅

  4. The other side of the mean. The same array gives more than 30 kWh in the best months. A surplus with no use is lost, and it does nothing for the worst month. ✅

Step 3: An array sized on the worst month

Click to reveal the calculation
  1. Size.

    That is 16.2 modules of 550 W. ✅

  2. The site as built. The site has 18 modules, 9.9 kWp. Its margin over the worst-month size is percent. ✅

  3. The cost of the choice. Sizing on the worst month needs times the array of the mean-month size: 22 percent more modules, which is the ratio . ✅

Step 4: Single days inside the worst month

Click to reveal the calculation
  1. The days. Thirty generated days with cloud=0.5, each with its own clouds, are scaled to a mean of 4.50 peak sun hours. The lowest has 3.86 and the highest 5.24. ✅

  2. Array energy. With 9.9 kWp and a performance ratio of 0.75 the mean day gives 33.4 kWh, the lowest 28.7 kWh and the highest 38.9 kWh. ✅

  3. Days below the load. One day of the 30 is below 30 kWh, and the energy short on it is 1.3 kWh. The 11.4 percent margin covers the scatter of these days almost fully. ✅

Step 5: Check by ratio

Click to reveal the check
  1. The shortfall without the array. An array that just meets the load at 5.5 peak sun hours gives of it at 4.5. The shortfall is , 18.2 percent, whatever the array size and performance ratio, as in Step 2. ✅

  2. In kWh. kWh a day. ✅

Verify It in Python



The script holds the course generator for one day of irradiance, the noon geometry of the site and both applications, and saves one plot of the three days and the thirty days of the worst month.

solar_resource.py
"""The solar resource: irradiance, peak sun hours, the sun's path and the worst month."""
import numpy as np
import matplotlib.pyplot as plt
def daily_irradiance(day=0, seed=5, step_min=5, psh=5.5, cloud=0.0):
"""Plane-of-array irradiance (W/m2) through one day near the equator.
Clear shape: sine squared between 06:30 and 18:30 scaled to `psh` peak sun hours.
`cloud` between 0 and 1 adds passing cloud. Returns hours, irradiance."""
rng = np.random.default_rng(seed + day)
h = np.arange(0, 24, step_min / 60.0)
x = np.clip((h - 6.5) / 12.0, 0, 1)
g = np.sin(np.pi * x) ** 2
g = g * psh / (g.sum() * step_min / 60.0) * 1000.0
if cloud > 0:
k = np.ones_like(h)
for _ in range(int(12 * cloud)):
c = rng.uniform(7, 18); w = rng.uniform(0.1, 0.6)
k *= 1 - 0.6 * np.exp(-0.5 * ((h - c) / w) ** 2)
g = g * k
return h, g
def insolation(g, step_min=5):
"""Insolation (kWh/m2) from irradiance samples (W/m2) at equal time steps."""
return g.sum() * step_min / 60.0 / 1000.0
def declination(n):
"""Declination of the sun (degrees) on day n of the year (Cooper's equation)."""
return 23.45 * np.sin(np.radians(360.0 * (284 + n) / 365.0))
# ---------- The sun at noon over the site ----------
LAT, TILT = -1.0, 10.0 # latitude (south is negative), roof tilt facing north
print("The sun at solar noon, latitude 1 deg S, roof tilted 10 deg to the north")
for name, n in (("21 March", 80), ("21 June", 172), ("22 September", 265),
("21 December", 355)):
north = declination(n) - LAT # angle of the noon sun from overhead, north positive
zen = abs(north)
inc = abs(north - TILT)
print(f" {name:13s} declination {declination(n):+6.2f}, sun {zen:5.2f} deg from overhead "
f"to the {'north' if north > 0 else 'south'}, air mass {1 / np.cos(np.radians(zen)):.2f}, "
f"cosine flat {np.cos(np.radians(zen)):.3f}, tilted {np.cos(np.radians(inc)):.3f}")
print(f" air mass 1.5 is a sun {np.degrees(np.arccos(1 / 1.5)):.1f} deg from overhead; "
f"cos(10 deg) = {np.cos(np.radians(10.0)):.3f}")
# ---------- Application 1: from irradiance to peak sun hours ----------
print("Application 1: one day of irradiance on the array plane")
h, clear = daily_irradiance()
_, half = daily_irradiance(cloud=0.5)
_, full = daily_irradiance(cloud=1.0)
hourly = np.arange(7, 19) * 12 # index of 07:00, 08:00, ... 18:00
print(" hour: " + " ".join(f"{int(v):4d}" for v in h[hourly]))
print(" clear W/m2: " + " ".join(f"{v:4.0f}" for v in clear[hourly]))
print(" cloudy W/m2: " + " ".join(f"{v:4.0f}" for v in half[hourly]))
print(f" clear day: peak {clear.max():.1f} W/m2 at {h[clear.argmax()]:.2f} h, "
f"hourly sum {clear[hourly].sum() / 1000:.3f}, 5 minute sum {insolation(clear):.3f} kWh/m2")
print(f" half the peak times 12 h: {0.5 * clear.max() * 12 / 1000:.3f} kWh/m2")
print(f" hours above 800 W/m2: {(clear > 800).sum() * 5 / 60:.2f}, "
f"above 500 W/m2: {(clear > 500).sum() * 5 / 60:.2f}")
mid = (h >= 10) & (h < 14)
print(f" share of the day's energy between 10:00 and 14:00: "
f"{100 * insolation(clear[mid]) / insolation(clear):.1f} %")
for name, g in (("cloud=0.5", half), ("cloud=1.0", full)):
print(f" {name}: peak {g.max():.1f} W/m2, hourly sum {g[hourly].sum() / 1000:.3f}, "
f"5 minute sum {insolation(g):.3f} kWh/m2 "
f"({100 * insolation(g) / insolation(clear):.1f} % of clear), "
f"hourly error {100 * (g[hourly].sum() / 1000 / insolation(g) - 1):+.1f} %")
i13 = int(np.argmin(np.abs(h - 13.0)))
print(f" at 13:00: clear {clear[i13]:.0f}, cloud=0.5 {half[i13]:.0f} W/m2; "
f"lowest ratio to clear in the day {np.nanmin(half[mid] / clear[mid]):.2f}")
# ---------- Application 2: energy for the mean and the worst month ----------
KWP, PR, LOAD = 9.9, 0.75, 30.0
H_MEAN, H_WORST = 5.5, 4.5
print("Application 2: energy from the 9.9 kWp array at a performance ratio of 0.75")
for name, H in (("yearly mean", H_MEAN), ("worst month", H_WORST)):
e = KWP * H * PR
print(f" {name}: {H} peak sun hours gives {e:.1f} kWh a day, "
f"{e - LOAD:+.1f} kWh against a load of {LOAD:.0f}")
print(f" a year at the mean: {KWP * H_MEAN * PR * 365:,.0f} kWh, "
f"{H_MEAN * PR * 365:,.0f} kWh for each kWp")
kwp_mean = LOAD / (H_MEAN * PR)
kwp_worst = LOAD / (H_WORST * PR)
e_short = kwp_mean * H_WORST * PR
print(f" array sized on the mean: {kwp_mean:.2f} kWp ({kwp_mean / 0.55:.1f} modules); "
f"in the worst month it gives {e_short:.1f} kWh a day, "
f"short by {LOAD - e_short:.2f} kWh ({100 * (LOAD - e_short) / LOAD:.1f} %)")
print(f" shortfall over a 30 day month: {30 * (LOAD - e_short):.0f} kWh, "
f"{30 * (LOAD - e_short) * 22:,.0f} currency units from the grid")
print(f" array sized on the worst month: {kwp_worst:.2f} kWp ({kwp_worst / 0.55:.1f} modules); "
f"the site's 9.9 kWp has a margin of {100 * (KWP / kwp_worst - 1):.1f} %")
raw = np.array([insolation(daily_irradiance(day=d, cloud=0.5)[1]) for d in range(30)])
days = raw * H_WORST / raw.mean() # thirty cloudy days scaled to the worst-month mean
e_days = KWP * days * PR
print(f" 30 generated cloudy days scaled to a mean of {days.mean():.2f}: "
f"lowest {days.min():.2f}, highest {days.max():.2f} kWh/m2")
print(f" array energy on those days: mean {e_days.mean():.1f}, lowest {e_days.min():.1f}, "
f"highest {e_days.max():.1f} kWh; days below the load of {LOAD:.0f} kWh: "
f"{(e_days < LOAD).sum()} of 30")
print(f" energy short on those days: {np.clip(LOAD - e_days, 0, None).sum():.1f} kWh in the month")
# ---------- Plot ----------
fig, ax = plt.subplots(2, 1, figsize=(8, 8))
ax[0].plot(h, clear, label="clear, 5.50 kWh/m2")
ax[0].plot(h, half, label=f"cloud=0.5, {insolation(half):.2f} kWh/m2")
ax[0].plot(h, full, label=f"cloud=1.0, {insolation(full):.2f} kWh/m2")
ax[0].axhline(1000.0, color="gray", linewidth=0.8, linestyle="--")
ax[0].set_xlim(5, 20)
ax[0].set_xlabel("hour of the day")
ax[0].set_ylabel("irradiance on the array plane (W/m2)")
ax[0].set_title("One day of irradiance (generated)")
ax[0].legend()
ax[1].bar(np.arange(30), e_days)
ax[1].axhline(LOAD, color="black", linewidth=0.8)
ax[1].set_xlabel("day")
ax[1].set_ylabel("array energy (kWh)")
ax[1].set_title("Thirty generated days of a worst month against a load of 30 kWh")
fig.tight_layout()
fig.savefig("solar_resource.png", dpi=120)
print("Saved solar_resource.png")

Expected output

The sun at solar noon, latitude 1 deg S, roof tilted 10 deg to the north
21 March declination -0.40, sun 0.60 deg from overhead to the north, air mass 1.00, cosine flat 1.000, tilted 0.987
21 June declination +23.45, sun 24.45 deg from overhead to the north, air mass 1.10, cosine flat 0.910, tilted 0.968
22 September declination -0.61, sun 0.39 deg from overhead to the north, air mass 1.00, cosine flat 1.000, tilted 0.986
21 December declination -23.45, sun 22.45 deg from overhead to the south, air mass 1.08, cosine flat 0.924, tilted 0.844
air mass 1.5 is a sun 48.2 deg from overhead; cos(10 deg) = 0.985
Application 1: one day of irradiance on the array plane
hour: 7 8 9 10 11 12 13 14 15 16 17 18
clear W/m2: 16 134 340 577 782 901 901 782 577 340 134 16
cloudy W/m2: 9 58 329 577 782 889 688 444 495 144 128 16
clear day: peak 916.7 W/m2 at 12.50 h, hourly sum 5.500, 5 minute sum 5.500 kWh/m2
half the peak times 12 h: 5.500 kWh/m2
hours above 800 W/m2: 2.75, above 500 W/m2: 5.58
share of the day's energy between 10:00 and 14:00: 59.8 %
cloud=0.5: peak 889.6 W/m2, hourly sum 4.558, 5 minute sum 4.388 kWh/m2 (79.8 % of clear), hourly error +3.9 %
cloud=1.0: peak 768.8 W/m2, hourly sum 3.105, 5 minute sum 3.114 kWh/m2 (56.6 % of clear), hourly error -0.3 %
at 13:00: clear 901, cloud=0.5 688 W/m2; lowest ratio to clear in the day 0.40
Application 2: energy from the 9.9 kWp array at a performance ratio of 0.75
yearly mean: 5.5 peak sun hours gives 40.8 kWh a day, +10.8 kWh against a load of 30
worst month: 4.5 peak sun hours gives 33.4 kWh a day, +3.4 kWh against a load of 30
a year at the mean: 14,906 kWh, 1,506 kWh for each kWp
array sized on the mean: 7.27 kWp (13.2 modules); in the worst month it gives 24.5 kWh a day, short by 5.45 kWh (18.2 %)
shortfall over a 30 day month: 164 kWh, 3,600 currency units from the grid
array sized on the worst month: 8.89 kWp (16.2 modules); the site's 9.9 kWp has a margin of 11.4 %
30 generated cloudy days scaled to a mean of 4.50: lowest 3.86, highest 5.24 kWh/m2
array energy on those days: mean 33.4, lowest 28.7, highest 38.9 kWh; days below the load of 30 kWh: 1 of 30
energy short on those days: 1.3 kWh in the month
Saved solar_resource.png

Common Mistakes



  • Reading nameplate power as the power to expect at noon. Nameplate is the output at 1,000 W/m² and a cell at 25 °C, and the clear day of this lesson never passed 917 W/m².
  • Confusing peak sun hours with hours of daylight or hours of sunshine. The site has 12 hours of daylight and 5.5 peak sun hours.
  • Using horizontal irradiance from a weather station or a database as if it were plane-of-array irradiance. Ask for the value at the tilt and direction of the array.
  • Sizing on the yearly mean when the load must be supplied in every month. The mean is for yearly energy. The worst month is for supply.
  • Judging the day from one reading of power. Passing cloud removed 20 percent of a day’s energy in the example while the peak stayed almost unchanged.
  • Laying modules flat near the equator because the sun is overhead. Standing water and dirt cost many times the small gain in angle.

Summary



  • Irradiance is power on a surface in W/m². Insolation is the energy of a day in kWh/m², and the same number is the peak sun hours: the hours at 1,000 W/m² that would give the same energy.
  • The daily energy of an array is , with the insolation taken in the plane of the array.
  • The air weakens the light more when the sun is low (a larger air mass), and cloud changes direct light into a smaller amount of diffuse light.
  • Near the equator the noon sun stays within about 24° of overhead and the day is 12 hours long all year, so cloud decides the seasons. A tilt of about 10° is kept so that rain washes the modules.
  • The clear day of the site gave 5.50 peak sun hours with a peak of 916.7 W/m². Passing cloud gave 4.39 and heavier cloud 3.11.
  • The 9.9 kWp array at a performance ratio of 0.75 gives 40.8 kWh on a mean day and 33.4 kWh in the worst month. An array sized on the mean for a 30 kWh load would be 18.2 percent short in the worst month.

Exercises



1. A sensor in the plane of an array gives these readings on the hour from 07:00 to 18:00, in W/m²: 50, 200, 420, 610, 760, 850, 830, 700, 520, 300, 120, 30. Find the insolation of the day and its peak sun hours.

Answer

The sum is 5,390 Wh/m², so kWh/m² and the day has 5.39 peak sun hours. Each reading stands for one hour.

2. An array of 5.0 kWp receives 4.8 peak sun hours in its plane. The performance ratio is 0.78. Find the energy of the day at the inverter output.

Answer

kWh.

3. A site is at latitude 10° north. On 21 December the declination is . Find the angle of the noon sun from overhead, the air mass at noon, the cosine factor for direct light on a flat surface, and the cosine factor on a surface tilted 15° towards the south.

Answer

, with the sun to the south. Air mass . Flat surface: . Tilted 15° south, the angle of incidence is and the factor is 0.949.

4. A clinic uses 12 kWh a day in every month. The plane-of-array resource is 5.2 peak sun hours as the yearly mean and 3.9 in the worst month. The performance ratio is 0.75. Find the array size on the mean, the array size on the worst month, and the daily shortfall in the worst month if the array is sized on the mean.

Answer

On the mean: kWp. On the worst month: kWp. Shortfall with the mean size: kWh a day, which is 25 percent of the load.

5. A clear day has the shape of a sine squared, with a peak of 850 W/m² and 11 hours between the start and the end of the light. Find the insolation. Then a cloud removes 60 percent of the light for 1.5 hours centred on the peak. Estimate the new insolation, first by taking the irradiance as equal to the peak during the cloud, then say whether the true loss is larger or smaller than that estimate.

Answer

Clear: Wh/m² kWh/m². Estimated loss: Wh/m², which leaves 3.91 kWh/m². The true loss is a little smaller (753 Wh/m², leaving 3.92), because the irradiance is slightly below the peak on both sides of it.

References



  • J. A. Duffie and W. A. Beckman, Solar Engineering of Thermal Processes, 4th edition, Wiley, 2013.
  • G. M. Masters, Renewable and Efficient Electric Power Systems, 2nd edition, Wiley, 2013.
  • R. A. Messenger and A. Abtahi, Photovoltaic Systems Engineering, 4th edition, CRC Press, 2017.
  • IEC 61724-1, Photovoltaic system performance: Monitoring (named here as the reference for how irradiance and energy are measured on a working system).


© 2021-2026 SiliconWit®. All rights reserved.
Predict first

On a clear day near the equator the sun shines on the roof from 06:30 to 18:30, twelve hours, with no cloud at all. How many peak sun hours does the roof receive?

rain nowwater by evening irradiance, W/m²insolation, kWh/m² Peak sun hours: hours of full rain that give the same water.
See it: the area under the day is the peak sun hours

Peak sun hours so far
Highest irradiance so far
Array energy, 9.9 kWp at PR 0.75

The three days are the course generator for the site, in the plane of the array, at 5-minute steps. The shaded area is the energy collected so far. When the day ends, the gold block is 1,000 W/m² high and holds the same area: its width is the peak sun hours. Compare the highest irradiance with the energy: passing cloud hardly moves the peak and still removes a fifth of the day.

Array of 7.27 kWp, sized for 30 kWh at 5.5 peak sun hours load, 30 kWh a day 30 kWh24.5 kWh mean month, 5.5 hworst month, 4.5 h 5.45 kWh short18 % of the load

Check yourself

Three questions. Each wrong choice is a mistake people really make, so read the note after you answer.

1. A clear day has the shape of a sine squared, with 12 hours of light and a peak of 800 W/m² in the plane of the array. How many peak sun hours does it give?

2. An array of 6 kWp receives 4.8 peak sun hours in its plane. The performance ratio is 0.8. About how much energy does it give in the day at the inverter output?

3. A clinic needs 20 kWh every day of the year. Its roof gets 6.0 peak sun hours as the yearly mean and 4.0 in the worst month. The performance ratio is 0.75. Which array supplies the load in every month?

Watch it build: the noon sun on a tilted roof
northsouth 10° G × cos θθ: from theperpendicular θ cos θ 10° 0.985 30° 0.866 60° 0.500 JuneDec June 14.45°0.968 Dec 32.45°0.844 flat roof:0.910, 0.924 Best for a year:tilt ≈ latitude1° here: almost flat 10°: rain runs offand takes the dust.Flat: water stays,dirt dries on it.
  1. The roof tilts 10° to the north. Direct light at θ from its perpendicular gives G × cos θ.
  2. The cosine is flat near zero: 10° costs 1.5 percent, 30° costs 13.4 percent, 60° half.
  3. Noon sun in June: 14.45° from the perpendicular, factor 0.968. In December: 32.45°, factor 0.844.
  4. For the most energy in a year: face the equator and tilt by the latitude, here 1°.
  5. A flat module holds water and dust. At 10° the rain runs off and washes the glass.
sun: irradiance G, W/m² Array 9.9 kWp 18 modules, tilt 10° Hybrid inverter 8 kW Load 30 kWh a day Battery 15.4 kWh G Grid and generator
The site of this course
direct one straight line, sharp shadows cloud diffuse from the whole sky module A shadow from a pole removes the direct part, not the diffuse part.
Direct and diffuse light on a module