The parts of a finding
“The measure reduced energy use by 11.5 percent (range 10.8 to 12.1) over days 500 to 729, against a baseline adjusted for weather and weekdays.”
An engineer spends two weeks on a year of readings and delivers thirty pages of plots. The manager reads the first page, finds no answer, and decides from memory. Another engineer delivers one line, “we saved 23 percent”, and the first question in the meeting (“compared with what?”) ends the discussion. Both did real work, and neither produced a finding. This lesson joins the methods of the course into one path from raw readings to a single sentence that carries a number, a range and a method, with one page of evidence behind it. #DataAnalysis #EngineeringReports #EnergySavings
By the end of this lesson, you will be able to:
A building owner paid for an energy-saving measure, installed on day 500 of a two-year record. The owner asks: did it work, and how much did it save? The answer decides whether the same measure goes into four more buildings.
A water committee runs a borehole pump. Its daily volume rose from about 78 to about 100 m³ within two months. The committee asks: is the estate using more water, or is water being lost? One answer leads to a larger pump and the other to a repair.
Neither question is answered by a plot. Each needs a sentence that a person without statistics can act on and an engineer who doubts it can check. The path to that sentence is the same on both sites.
A finding is a statement that can be acted on and can be checked. It has four parts, and it fails if any one is missing.
The parts of a finding
“The measure reduced energy use by 11.5 percent (range 10.8 to 12.1) over days 500 to 729, against a baseline adjusted for weather and weekdays.”
Without the range, nobody knows whether 11.5 means “between 11 and 12” or “between 2 and 21”; without the period, the number cannot be compared with any other; without the method, it cannot be repeated.
Check the data. Count the readings against the number expected. Put every time stamp in UTC and look for repeated time stamps. Look for gaps, flatlines, spikes, values outside the sensor’s range and changes of unit. Flag them and state the coverage.
Describe it. Mean, spread, percentiles and a histogram. Find out whether the data has one kind of day or two.
Profile it. Draw the typical day and the typical week. Read the base load and the peak.
Build a baseline and test it. Model what the site does when nothing is wrong, from a period you trust. Then test the model on a second period that it has not seen, in which nothing changed.
Look for change. Chart the difference between the readings and the baseline. Find whether a change exists and on which day it began.
Quantify with uncertainty. State the size of the change over a named period, with an expanded uncertainty, and say what that uncertainty leaves out.
Write it. One sentence, then one page.
The order matters. A baseline fitted to unchecked data learns the faults. A change found without a baseline may be the weather. A size without a date mixes the periods before and after the change.
Three of the steps can end the work early, and each early end is still a finding.
“No saving larger than 1.4 percent can be seen in 30 days” is a correct and useful finding. It tells the owner how long to wait.
The sentence goes at the top. Under it, six short entries let a reader judge it.
Most reports leave out the last two entries. “Not checked” lists what the analysis did not cover, so the reader does not assume it did. “Would change it” names the facts that would overturn the conclusion, so a person who knows the site can say whether one is true.
Check. The record holds 730 of 730 days. No value is missing and none repeats the value before it. Energy lies between 210.6 and 969.5 kWh, and temperature between 12.6 and 29.0 °C. The coverage is 100 percent. ✅
Describe. In the first year the mean is 575.8 kWh a day and the standard deviation is 154.7 kWh. A spread of 27 percent of the mean says that one number does not describe a day. ✅
Profile. In the first year, weekdays have a mean of 629.5 kWh and weekend days 440.9 kWh. The building has two kinds of day, so the baseline needs a weekday term. ✅
Check the range of the driver. The fitting year covers 12.6 to 29.0 °C. The reporting period covers 13.3 to 27.9 °C, which is inside it. The baseline will not be used outside the weather it was fitted to. ✅
Baseline. Least squares on days 0 to 364 gives
where CDD is the cooling degree days of the day and
Test on unseen days. Over days 365 to 499 the baseline gives 90,526 kWh and the meter recorded 91,010 kWh. The error is
Look for change. An EWMA chart of the residuals (measured minus baseline) has limits of
Compare with the site record. The data shows a step down two days after the date in the site record. The date in the finding is day 500, from the record. The data confirms it and does not replace it. ✅
Adjusted baseline and measured energy, days 500 to 729.
Avoided energy.
This is 60.2 kWh a day. ✅
Expanded uncertainty, simple form.
The range is 13,029 to 14,685 kWh, or 10.8 to 12.1 percent. ✅
What the plain comparison would have said. The mean fell from 602.3 kWh a day (days 0 to 499) to 465.3 (days 500 to 729), which is 22.8 percent. Half of that is cooler weather. ✅
Check a second way: split the period. If the measure is real, both parts of the period should show it.
| Part | Mean temperature | Baseline (kWh) | Saving (kWh) | Saving |
|---|---|---|---|---|
| Days 500 to 589 | 22.6 °C | 56,686 | 6,477 | 11.4 % |
| Days 590 to 729 | 17.5 °C | 64,185 | 7,380 | 11.5 % |
A warm part and a cool part give the same percentage. The saving is not produced by one season. ✅
The sentence. “The measure installed on day 500 reduced energy use by 11.5 percent (range 10.8 to 12.1), which is 13,857 kWh over 230 days (range 13,029 to 14,685), against a baseline adjusted for weather and weekdays.” ✅
The page.
| Entry | Content |
|---|---|
| Question | Did the measure installed on day 500 reduce energy use, and by how much? |
| Data | Daily energy from the main meter and daily mean outdoor temperature, days 0 to 729. 730 of 730 days present. |
| Method | Baseline 306.6 + 41.61 CDD + 182.1 weekday (kWh a day), fitted on days 0 to 364, RMSE 27.30 kWh. Tested on days 365 to 499: error |
| Result with range | Avoided energy 13,857 kWh (13,029 to 14,685), 11.5 percent of the adjusted baseline (10.8 to 12.1), 60.2 kWh a day. Range is |
| Not checked | Uncertainty of the baseline coefficients (it widens the range to 10.6 to 12.4 percent). Changes of occupancy or equipment after day 500. Calibration of the meter. Days hotter than 27.9 °C. Whether the saving lasts beyond day 729. |
| Would change it | Another change on site near day 500 (fewer people, shorter hours, equipment removed). A different percentage in the next hot season. |
✅
Compare with the truth. The data was generated with a reduction of 12 percent from day 500. The true value is inside the reported range. ✅
Check. Flow and power each hold 1,440 of 1,440 hourly readings, with none missing and none repeated. Flow lies between 0.4 and 7.1 m³/h. The coverage is 100 percent. ✅
Describe. The mean daily volume is 77.6 m³ over days 0 to 34 and 99.6 m³ over days 35 to 59. The rise is 22.0 m³ a day, 28.4 percent. ✅
Profile. Subtract the mean 24-hour profile of days 0 to 34 from that of days 35 to 59. The difference has a mean of 0.917 m³/h. It lies between 0.78 and 1.10 m³/h at every one of the 24 hours: 0.899 at night and 0.926 by day. ✅
Read the shape. The same amount was added at every hour, including the hours when taps are closed. That is the shape of a constant loss. ✅
Choose the sharpest series. The mean night flow of each day gives 60 values. At night the demand is small and steady, so a constant addition stands out most clearly there. ✅
Reference. Over days 0 to 19 the night flow has a mean of
Test on unseen days. Days 20 to 34 were not used for the reference. Their mean is 0.603 m³/h, and no day is further than 2.2 standard deviations from
Look for change. The tabular CUSUM signals on day 35, and the count since its last zero places the start on day 35. In the hourly record the flow is 0.67 m³/h at 23:00 on day 34 and 1.50 m³/h at 00:00 on day 35. ✅
Size. The mean night flow from day 35 is 1.499 m³/h.
The standard error of the difference of the two means, doubled, is 0.017 m³/h. The step is
Water lost. Days 35 to 59 are 25 days.
This is 21.6 m³ a day, which is 22 percent of all the water pumped since day 35. ✅
Pumping energy. The pump’s energy for each cubic metre rises slowly with wear, so take each day’s own value: the day’s energy divided by the day’s volume. Over days 35 to 59 it is 0.450 kWh per m³ overall. Multiplying each day’s lost 21.6 m³ by that day’s value and adding gives 243 kWh (range 238 to 248). The loss now costs 10.0 kWh a day. ✅
Check a second way. The rise in daily volume is
More users. If use had grown by 28.4 percent at every hour, the night flow would have risen by 0.17 m³/h. It rose by 0.90. Extra use by day would not raise the night flow at all. ✅
A slow growth of demand. Growth would arrive over weeks. This change arrived between two hourly readings. ✅
A fault of the flow meter. A meter that began to read 0.9 m³/h too high would give the same flow record. The power is measured separately. If no extra water were pumped, the energy would not rise and the energy for each cubic metre would fall to about 0.342 kWh per m³. It was 0.4385 over days 30 to 34 and 0.4431 over days 35 to 39. The daily energy rose from 33.3 to 44.8 kWh. The water was really pumped. ✅
What the record cannot separate. A tank float valve stuck open, or a tap left running, is also a constant flow. The record says that 0.90 m³/h leaves the system at every hour. It does not say where. The next check is on site: at about 03:00 the meter should read about 1.5 m³/h; close one part of the network at a time and watch for the closure that removes about 0.9 m³/h. ✅
The sentence. “A constant loss of about 0.90 m³/h (range 0.88 to 0.92) began at the start of day 35, and by the end of day 59 it had cost about 541 m³ of water and about 243 kWh of pumping energy.” ✅
The page.
| Entry | Content |
|---|---|
| Question | Is the rise in pumped volume extra use or a loss, and how large is it? |
| Data | Hourly flow and power, days 0 to 59. 1,440 of 1,440 hours present. |
| Method | Mean night flow of each day. Reference from days 0 to 19, tested on days 20 to 34. Tabular CUSUM with |
| Result with range | Start: day 35. Size: 0.90 m³/h (0.88 to 0.92). Water: 541 m³ in 25 days (530 to 551), 21.6 m³ a day. Energy: 243 kWh (238 to 248), now 10.0 kWh a day. |
| Evidence | Night flow 0.60 before and 1.50 after. Profile difference of 0.78 to 1.10 m³/h at all 24 hours. Energy for each cubic metre did not fall at day 35. |
| Not checked | Where the water goes. Whether a loss was already present in days 0 to 19 (it would be hidden inside the reference). |
| Would change it | A known new night user from day 35, such as a tank filled at night. |
✅
Compare with the truth. The data was generated with a leak of 0.9 m³/h from hour 0 of day 35, which is 540 m³ in 25 days. ✅
A meter measures and a model estimates. A saving or a loss is always the difference between the two, so it is an estimate.
| Statement | Kind |
|---|---|
| The meter recorded 107,014 kWh | Measured |
| The baseline for the same days is 120,871 kWh | Estimated |
| The measure avoided 13,857 kWh | Estimated (measured minus estimated) |
| The night flow rose from 0.60 to 1.50 m³/h | Measured |
| A leak takes 0.90 m³/h | Estimated (inferred from the rise) |
Write “the meter recorded” for the first kind and “we estimate” or “about” for the second. Never write “measured savings”.
“13,857 kWh” claims five figures of knowledge. The range of 13,029 to 14,685 shows that only the first two are known. In a sentence for a manager, “about 13,900 kWh (13,000 to 14,700)” is more honest than the unrounded figure.
| Avoid | Reason | Write |
|---|---|---|
| ”proves” | Data supports a conclusion within a range | ”shows”, “is consistent with" |
| "exactly”, “precisely” | No estimate is exact | ”about”, with the range |
| ”will save” | The period measured is the past | ”saved, over days 500 to 729" |
| "significant” alone | It has a statistical meaning and an everyday one | State the size and the range |
| ”caused by” | The record shows when and how much, not why | ”began on”, “coincides with" |
| "no change” | Absence of a signal is not absence of a change | ”no change larger than X could be seen” |
The script follows the seven steps for both sites and prints every number used above. It saves one figure: the cumulative avoided energy of the building, and the night flow of the borehole.
"""From raw readings to one finding: a building's saving and a borehole's leak."""import numpy as npimport matplotlib.pyplot as plt
def building_daily(seed=23, days=730): rng = np.random.default_rng(seed) d = np.arange(days) temp = 21.0 + 4.5 * np.sin(2 * np.pi * (d - 20) / 365.0) + rng.normal(0, 1.6, days) weekday = (d % 7) < 5 # day 0 is a Monday cdd = np.clip(temp - 18.0, 0.0, None) # cooling degree days, base 18 °C energy = 310.0 + 42.0 * cdd + np.where(weekday, 180.0, 0.0) + rng.normal(0, 28.0, days) # an energy-saving measure is installed on day 500: 12 percent less from then on energy[500:] *= 0.88 return d, temp, weekday, energy # kWh a day
def borehole_hourly(seed=37, days=60): rng = np.random.default_rng(seed) h = np.arange(days * 24); hour = h % 24 demand = np.where((hour >= 6) & (hour < 22), 4.6, 0.6) # m3/h drawn by users demand = demand * (1.0 + rng.normal(0, 0.12, h.size)) leak = np.where(h >= 35 * 24, 0.9, 0.0) # a leak starts on day 35 flow = np.clip(demand + leak, 0, None) # m3/h kwh_per_m3 = 0.42 + 0.0006 * (h / 24.0) # slow wear: rising power = flow * kwh_per_m3 * (1.0 + rng.normal(0, 0.03, h.size)) # kW return h, flow, power
def check_record(x, expected): """Step 1 of the method: count, gaps, repeats and range.""" repeats = int((np.diff(x) == 0).sum()) return (f"{x.size} of {expected} readings, {int(np.isnan(x).sum())} missing, " f"{repeats} repeated values, range {np.nanmin(x):.1f} to {np.nanmax(x):.1f}")
def ewma(x, lam=0.2): z = np.empty(x.size); prev = 0.0 for i, v in enumerate(x): prev = lam * v + (1.0 - lam) * prev z[i] = prev return z
def tabular_cusum(x, mu0, k, h): """Upper tabular CUSUM: first signal index and the count since the last zero.""" prev, count = 0.0, 0 for i, v in enumerate(x): prev = max(0.0, prev + v - mu0 - k) count = count + 1 if prev > 0.0 else 0 if prev > h: return i, count return None, 0
# ================= Application 1: data set B, the building =================d, temp, weekday, energy = building_daily()cdd = np.clip(temp - 18.0, 0.0, None)fit, chk, rep = slice(0, 365), slice(365, 500), slice(500, 730)print("Building. Step 1, check the data")print(f" energy: {check_record(energy, 730)} kWh")print(f" temperature: {check_record(temp, 730)} degC")print(f" temperature in the fitting year {temp[fit].min():.1f} to {temp[fit].max():.1f}, " f"in the reporting period {temp[rep].min():.1f} to {temp[rep].max():.1f} degC")
print("Step 2, describe; step 3, profile")print(f" first year: mean {energy[fit].mean():.1f}, standard deviation " f"{energy[fit].std(ddof=1):.1f} kWh a day")print(f" first year: weekdays {energy[fit][weekday[fit]].mean():.1f}, weekend days " f"{energy[fit][~weekday[fit]].mean():.1f} kWh a day")
print("Step 4, baseline; step 5, test it")X = np.column_stack([np.ones(d.size), cdd, weekday.astype(float)])b, *_ = np.linalg.lstsq(X[fit], energy[fit], rcond=None)res = energy - X @ brmse = np.sqrt(np.sum(res[fit] ** 2) / (365 - 3))print(f" energy = {b[0]:.1f} + {b[1]:.2f} x CDD + {b[2]:.1f} x weekday")print(f" RMSE {rmse:.2f} kWh, CV(RMSE) {100 * rmse / energy[fit].mean():.1f} %")baseline = X @ berr = energy[chk].sum() - baseline[chk].sum()print(f" days 365 to 499: baseline {baseline[chk].sum():.0f}, measured " f"{energy[chk].sum():.0f}, error {err:+.0f} kWh ({100 * err / baseline[chk].sum():+.2f} %), " f"allowed {2 * rmse * np.sqrt(135):.0f}")
print("Step 6, look for change")sigma = np.abs(np.diff(res[fit])).mean() / 1.128limit = 3.0 * sigma * np.sqrt(0.2 / 1.8)z = ewma(res[365:])days2 = d[365:]out = days2[np.abs(z) > limit]print(f" EWMA of the residuals: limits +/-{limit:.1f} kWh, signals before day 500: " f"{out[out < 500].tolist()}, first signal after: day {out[out >= 500][0]}")print(f" mean residual: days 365 to 499 {res[chk].mean():+.1f}, " f"days 500 to 729 {res[rep].mean():+.1f} kWh a day")
print("Step 7, quantify")m = 230B, M = baseline[rep].sum(), energy[rep].sum()S, U = B - M, 2 * rmse * np.sqrt(m)print(f" naive: {energy[:500].mean():.1f} to {energy[rep].mean():.1f} kWh a day = " f"{100 * (1 - energy[rep].mean() / energy[:500].mean()):.1f} %")print(f" adjusted baseline {B:.0f} kWh, measured {M:.0f} kWh")print(f" avoided energy {S:.0f} kWh = {100 * S / B:.2f} %, expanded uncertainty {U:.0f} kWh")print(f" range {S - U:.0f} to {S + U:.0f} kWh = {100 * (S - U) / B:.1f} to " f"{100 * (S + U) / B:.1f} %")print(f" a day: {S / m:.1f} kWh (range {(S - U) / m:.1f} to {(S + U) / m:.1f})")for name, part in (("days 500 to 589", slice(500, 590)), ("days 590 to 729", slice(590, 730))): Bp, Mp = baseline[part].sum(), energy[part].sum() Up = 2 * rmse * np.sqrt(part.stop - part.start) print(f" {name}: mean {temp[part].mean():.1f} degC, baseline {Bp:.0f}, saving " f"{Bp - Mp:.0f} kWh = {100 * (Bp - Mp) / Bp:.1f} % (+/- {100 * Up / Bp:.1f})")
# ================= Application 2: data set C, the borehole =================h, flow, power = borehole_hourly()table, ptable = flow.reshape(60, 24), power.reshape(60, 24)print("Borehole. Step 1, check the data")print(f" flow: {check_record(flow, 1440)} m3/h")print(f" power: {check_record(power, 1440)} kW")
print("Steps 2 and 3, describe and profile")volume, kwh = table.sum(axis=1), ptable.sum(axis=1)print(f" daily volume: days 0 to 34 {volume[:35].mean():.1f}, days 35 to 59 " f"{volume[35:].mean():.1f} m3")diff = table[35:].mean(axis=0) - table[:35].mean(axis=0)NIGHT = [0, 1, 2, 3, 4, 5, 22, 23]DAY = list(range(6, 22))print(f" profile difference: mean {diff.mean():.3f}, smallest {diff.min():.2f}, largest " f"{diff.max():.2f}, night {diff[NIGHT].mean():.3f}, day {diff[DAY].mean():.3f} m3/h")
print("Steps 4, 5 and 6, reference, test and change")night = table[:, NIGHT].mean(axis=1)mu0, s0 = night[:20].mean(), night[:20].std(ddof=1)print(f" night flow, days 0 to 19: mean {mu0:.4f}, s {s0:.4f} m3/h")print(f" days 20 to 34 (not used for the reference): mean {night[20:35].mean():.4f}, " f"largest distance from the reference {np.abs(night[20:35] - mu0).max() / s0:.1f} s")sig, count = tabular_cusum(night, mu0, 0.5 * s0, 5.0 * s0)start = sig - count + 1print(f" tabular CUSUM (k 0.5 s, h 5 s): signal on day {sig}, estimated start day {start}")
print("Step 7, quantify")n2 = 60 - startstep = night[start:].mean() - mu0u_step = np.sqrt(s0 ** 2 / 20 + night[start:].var(ddof=1) / n2)print(f" night flow: reference {mu0:.3f}, from day {start} {night[start:].mean():.3f}, " f"step {step:.3f} +/- {2 * u_step:.3f} m3/h")print(f" hourly flow: 23:00 on day {start - 1} {table[start - 1, 23]:.2f}, " f"00:00 on day {start} {table[start, 0]:.2f} m3/h")lost = step * 24 * n2print(f" water lost: {step * 24:.1f} m3 a day, {lost:.0f} m3 in {n2} days " f"(range {(step - 2 * u_step) * 24 * n2:.0f} to {(step + 2 * u_step) * 24 * n2:.0f})")dv = volume[start:].mean() - volume[:start].mean()u_dv = np.sqrt(volume[:start].var(ddof=1) / start + volume[start:].var(ddof=1) / n2)print(f" check from daily volume: rise {dv:.1f} +/- {2 * u_dv:.1f} m3 a day, " f"{dv * n2:.0f} m3 in {n2} days")spec = kwh / volume # kWh per m3, each dayprint(f" kWh per m3: days 30 to 34 {spec[30:35].mean():.4f}, days 35 to 39 " f"{spec[35:40].mean():.4f}, days {start} to 59 {kwh[start:].sum() / volume[start:].sum():.4f}")print(f" kWh per m3 expected if the meter read high and no extra water was pumped: " f"{spec[30:35].mean() * volume[:start].mean() / volume[start:].mean():.3f}")e_leak = np.sum(step * 24 * spec[start:])print(f" pumping energy of the lost water: {e_leak:.0f} kWh " f"(range {e_leak * (step - 2 * u_step) / step:.0f} to " f"{e_leak * (step + 2 * u_step) / step:.0f}), now {step * 24 * spec[59]:.1f} kWh a day")print(f" daily energy: {kwh[:start].mean():.1f} before, {kwh[start:].mean():.1f} kWh after")print(f" share of pumped water lost after day {start}: " f"{100 * step * 24 / volume[start:].mean():.0f} %")grow = volume[start:].mean() / volume[:start].mean() - 1print(f" if use had grown {100 * grow:.1f} %: night +{grow * mu0:.2f}, " f"measured +{step:.2f} m3/h")
# ---------- Plot ----------fig, ax = plt.subplots(2, 1, figsize=(8, 7))ax[0].plot(d[365:], np.cumsum(baseline[365:] - energy[365:]))ax[0].axvline(500, color="gray", linewidth=0.8)ax[0].set_xlabel("day")ax[0].set_ylabel("cumulative baseline minus measured (kWh)")ax[0].set_title("Building: avoided energy since day 365")ax[1].plot(np.arange(60), night, "o-", markersize=3)ax[1].axhline(mu0, color="gray", linewidth=0.8)ax[1].axvline(start - 0.5, color="gray", linewidth=0.8)ax[1].set_xlabel("day")ax[1].set_ylabel("mean night flow (m3/h)")ax[1].set_title("Borehole: night flow of each day")fig.tight_layout()fig.savefig("finding_from_data.png", dpi=120)print("Saved finding_from_data.png")Expected output
Building. Step 1, check the data energy: 730 of 730 readings, 0 missing, 0 repeated values, range 210.6 to 969.5 kWh temperature: 730 of 730 readings, 0 missing, 0 repeated values, range 12.6 to 29.0 degC temperature in the fitting year 12.6 to 29.0, in the reporting period 13.3 to 27.9 degCStep 2, describe; step 3, profile first year: mean 575.8, standard deviation 154.7 kWh a day first year: weekdays 629.5, weekend days 440.9 kWh a dayStep 4, baseline; step 5, test it energy = 306.6 + 41.61 x CDD + 182.1 x weekday RMSE 27.30 kWh, CV(RMSE) 4.7 % days 365 to 499: baseline 90526, measured 91010, error +484 kWh (+0.53 %), allowed 634Step 6, look for change EWMA of the residuals: limits +/-25.7 kWh, signals before day 500: [], first signal after: day 502 mean residual: days 365 to 499 +3.6, days 500 to 729 -60.2 kWh a dayStep 7, quantify naive: 602.3 to 465.3 kWh a day = 22.8 % adjusted baseline 120871 kWh, measured 107014 kWh avoided energy 13857 kWh = 11.46 %, expanded uncertainty 828 kWh range 13029 to 14685 kWh = 10.8 to 12.1 % a day: 60.2 kWh (range 56.6 to 63.8) days 500 to 589: mean 22.6 degC, baseline 56686, saving 6477 kWh = 11.4 % (+/- 0.9) days 590 to 729: mean 17.5 degC, baseline 64185, saving 7380 kWh = 11.5 % (+/- 1.0)Borehole. Step 1, check the data flow: 1440 of 1440 readings, 0 missing, 0 repeated values, range 0.4 to 7.1 m3/h power: 1440 of 1440 readings, 0 missing, 0 repeated values, range 0.2 to 3.1 kWSteps 2 and 3, describe and profile daily volume: days 0 to 34 77.6, days 35 to 59 99.6 m3 profile difference: mean 0.917, smallest 0.78, largest 1.10, night 0.899, day 0.926 m3/hSteps 4, 5 and 6, reference, test and change night flow, days 0 to 19: mean 0.5977, s 0.0269 m3/h days 20 to 34 (not used for the reference): mean 0.6034, largest distance from the reference 2.2 s tabular CUSUM (k 0.5 s, h 5 s): signal on day 35, estimated start day 35Step 7, quantify night flow: reference 0.598, from day 35 1.499, step 0.901 +/- 0.017 m3/h hourly flow: 23:00 on day 34 0.67, 00:00 on day 35 1.50 m3/h water lost: 21.6 m3 a day, 541 m3 in 25 days (range 530 to 551) check from daily volume: rise 22.0 +/- 1.2 m3 a day, 550 m3 in 25 days kWh per m3: days 30 to 34 0.4385, days 35 to 39 0.4431, days 35 to 59 0.4496 kWh per m3 expected if the meter read high and no extra water was pumped: 0.342 pumping energy of the lost water: 243 kWh (range 238 to 248), now 10.0 kWh a day daily energy: 33.3 before, 44.8 kWh after share of pumped water lost after day 35: 22 % if use had grown 28.4 %: night +0.17, measured +0.90 m3/hSaved finding_from_data.pngIn the upper plot the line is level until day 500 and then rises steadily. In the lower plot the night flow stays near the reference line for 35 days and then moves to a new level in one day.
1. Over a reporting period of 64 days, an adjusted baseline is 48,000 kWh and the meter recorded 44,400 kWh. The baseline has an RMSE of 40 kWh a day. Write the finding as one sentence with its range by the simple form.
2. The night flow of a site is 0.35 m³/h for days 0 to 11 and 0.80 m³/h from day 12 to day 29, the last day of the record. The pump uses 0.55 kWh for each cubic metre. Find the size of the loss, the water lost and the pumping energy, and say which of these figures were measured.
Size:
3. A baseline with an RMSE of 26 kWh a day and a mean of 500 kWh a day is applied to 100 days. The avoided energy is 300 kWh. Write the finding. How many days are needed before a saving of this percentage could be distinguished from zero?
4. The building in Application 1 saved 13,857 kWh in 230 days, which is 11.46 percent. Its first year used 575.8 kWh a day. Estimate a full year’s saving in two ways: from the kWh a day of the reporting period, and from the percentage applied to the first year’s energy. Which would you report, and with what caution?
By kWh a day:
5. A report says: “Our analysis proves that the new controller will save exactly 9.3 percent, a significant result.” The data behind it is an avoided energy of 9.3 percent with a range of 7.9 to 10.7 percent over days 200 to 320. Rewrite the sentence.
“Over days 200 to 320 the new controller reduced energy use by about 9.3 percent (range 7.9 to 10.7), against the adjusted baseline.” The words “proves”, “will”, “exactly” and “significant” are removed, and the period, the range and the method are added.
Thirty days after a measure, the saving is smaller than the 1.4 percent that the baseline can tell from zero in 30 days. Is there a finding to write?
The reporting period of the building in Application 1, cut into parts. For each part the saving is its adjusted baseline minus the meter, as a percentage of that baseline, with U = 2 × RMSE × √days. If the measure is real and not a product of one season, every part shows about the same percentage. Shorter parts have wider ranges, so do not cut too fine.
Three questions. Each wrong choice is a mistake people really make, so read the note after you answer.
1. A draft says: "The measure reduced energy use by 11.5 percent against a weather-adjusted baseline." What is missing before it is a finding?
2. An EWMA chart of the residuals gives no signal in the 30 days after a measure, and in 30 days the baseline can see a saving of 1.4 percent or more. Which sentence do you write?
3. The building's reporting period is split in two. The warm part (mean 22.6 °C) shows a saving of 11.4 ± 0.9 percent and the cool part (17.5 °C) 11.5 ± 1.0 percent. What does the split show?