Identical pumps in parallel
Pumps in Parallel and in Series
On this page
A site is short of water at the busiest hour, so the owner buys a second pump, identical to the first, and connects it beside the first. The owner expects twice the flow. The flow meter shows 15 percent more, and the electricity meter shows 27 percent more. Nothing is wrong with either pump. Two pumps share one pipe system, and the pipe system decides what the second pump can add. This lesson shows how to combine pump curves in parallel and in series, how to find what each pump does, and how to decide when the second pump should run. #ParallelPumps #SeriesPumps #PumpStations
Learning Objectives
By the end of this lesson, you will be able to:
- Build the combined curve of identical pumps in parallel and in series
- Solve the duty point of the combined pumps on a system curve and find each pump’s flow, efficiency and electrical input
- Explain why two pumps in parallel give less than twice the flow, and when they come close to it
- Predict when the weaker of two unequal pumps is pushed back to shut-off
- Decide from the electrical input at which flow a second pump should start
Real-World System Problem: A booster station with two pumps
The booster pump of this course supplies buildings whose demand moves between 6 and 24 m³/h. One pump at full speed reaches 23.34 m³/h on the distribution system, so it cannot meet the top of the demand. The station is therefore built with two identical pumps, side by side, drawing from the same tank and feeding the same main.
Two questions follow. What do the two pumps deliver together? And over which part of the demand should the second pump run? Start it too early and the station pays for two pumps working far from their best efficiency point; too late and it cannot hold the pressure.
Two pumps can also be connected one after the other, the second taking the discharge of the first. That serves a different kind of system, and the wrong arrangement gives almost nothing for the cost of a pump.
Fundamental Theory: Combining pump curves
Pumps in parallel
Two pumps in parallel draw from the same suction header and discharge into the same main. The pressure is the same at both inlets and the same at both outlets, so both pumps work at the same head. The main carries the sum of their flows.
To draw the combined curve, take one head, read the flow of each pump at that head, and add the flows. Repeat for other heads.
For identical pumps the rule becomes simple. At any head, each pump carries the same flow, so each carries the total flow divided by the number of pumps. If one pump has the curve
For two boosters,
A common mistake is to add the heads of pumps in parallel. Two pumps of 42 m shut-off head, side by side, still give 42 m at shut-off. They give more flow, not more head.
Why the flow does not double
The combined curve is twice as wide, but the duty point is where it crosses the system curve, which rises with flow: more flow in the same pipes needs more friction head. To supply it, each pump moves left on its own curve and delivers less than it did alone. Two taps filling one bucket through one thin hose do not fill it twice as fast.
On a steep system curve, the duty point moves from A to B: a little more flow at a clearly higher head. On a flat system curve, where nearly all the head is static, it moves from A to C: almost twice the flow at almost the same head.
For identical pumps on a system curve
What happens to each pump
When the second pump starts, each pump moves back on its curve, toward shut-off. When one of two stops, the other moves out to the right, toward run-out, and carries far more than its share.
Check both movements. A pump moved back may work at low efficiency, with recirculation. A pump left alone works at its largest flow, where its shaft power and NPSH required are highest. Size the motor and check the suction for one pump running alone, not for its share when both run.
Pumps in series
Two pumps in series carry the same water, one after the other, so the flow is the same in both. Each adds its head. To draw the combined curve, take one flow, read the head of each pump at that flow, and add the heads.
Identical pumps in series
The shut-off head is multiplied by
For two boosters,
Series pumps suit a system that needs more head than one pump can give: a high static lift, or a long, narrow pipe with a steep curve. The multistage borehole pump of this course is the same idea in one casing, with several impellers on one shaft, each adding its head to the same flow.
Choosing the arrangement
Unequal pumps
Parallel pumps do not need to be identical, but the weaker pump is at risk. Take the booster,
Speed control with more than one pump
When each pump has its own drive, identical pumps that run together are given the same speed, so that they share the flow equally. The affinity laws then apply to each pump with its own share of the flow. The efficiency of each pump is found from its equivalent full-speed flow, which is its share divided by the speed ratio
Application 1: Two boosters in parallel at full speed
Step 1: The combined curve and the duty point
Click to reveal where two pumps settle
-
Combined curve. At equal head each pump carries half of the total flow.
The combined curve has the same shut-off head and one quarter of the coefficient. ✅
-
Duty point. Set the combined curve equal to the system curve.
The two pumps together deliver 26.87 m³/h. ✅
-
Head.
The system curve gives the same:
m. The duty point is 26.87 m³/h at 39.83 m. ✅
Step 2: What each pump does
Click to reveal each pump’s share
-
Flow of each pump.
Each pump carries 13.44 m³/h, against 23.34 m³/h when it runs alone. On its own curve,
m, which agrees. ✅ -
Efficiency of each pump.
Each pump works at 65.5 percent, at 75 percent of its best efficiency flow. ✅
-
Power of each pump. With
: Each pump takes 2.525 kW, so the station takes 5.05 kW. ✅
-
Energy for each cubic metre.
One pump alone uses
kWh/m³. With two pumps each cubic metre costs 11 percent more. ✅
Step 3: The gain and its cause
Click to reveal why the flow did not double
-
Gain in flow.
The second pump adds 15.1 percent to the flow, and 27 percent to the electrical input (5.05 kW against 3.96 kW). ✅
-
Where the head went. The friction head of the system is
. With one pump it is 13.46 m. With two pumps it is 17.83 m. The 15 percent of extra flow needs 4.37 m of extra head, and the pumps can give it only by moving back on their curves to 13.44 m³/h each. ✅ -
What doubling would need. Twice the flow is 46.68 m³/h. At that flow the system needs
m. Two pumps in parallel never give more than 42 m. Doubling is impossible on these pipes. ✅ -
Check with the closed form. Here
and . The ratio is the same as in step 1. The system curve is twice as steep as the pump curve (
), and that fixes the result. ✅
Step 4: A flat system and a steep system
Click to reveal the two opposite cases
-
Flat system, one pump.
One pump delivers 22.09 m³/h at 36.15 m. ✅
-
Flat system, two pumps in parallel.
Two pumps deliver 42.64 m³/h at 36.55 m, a gain of 93.1 percent. Each pump carries 21.32 m³/h, almost what it carried alone. ✅
-
Steep system, one pump.
One pump delivers 9.53 m³/h at 40.91 m. It works at 53 percent of its best efficiency flow, with an efficiency of 0.594. ✅
-
Steep system, two pumps in parallel.
The second pump adds 0.35 m³/h, which is 3.6 percent. It is almost useless here. ✅
-
Steep system, two pumps in series. The combined curve is
. The head is
m, which is 37.5 m from each pump. The flow has doubled, and each pump now works at 19.36 m³/h with an efficiency of 0.678, close to its best. Each takes 3.31 kW. ✅
Application 2: When to start the second pump
Step 1: One pump at 18 m³/h
Click to reveal the single pump at the design flow
-
Head the system needs.
The hydraulic power is
W, whichever pumps supply it. ✅ -
Speed ratio. The pump curve at speed ratio
must pass through 18 m³/h at 30.00 m. One pump runs at 89.8 percent of full speed. ✅
-
Efficiency.
The pump works close to its best efficiency point. ✅
-
Electrical input.
One pump takes 2.549 kW. ✅
Step 2: Two pumps at 18 m³/h
Click to reveal the two pumps sharing the same flow
-
Speed ratio. Each pump carries 9 m³/h at the same 30.00 m.
Both pumps run at 85.9 percent of full speed. ✅
-
Efficiency.
Each pump is far to the left of its best efficiency point. ✅
-
Total electrical input. The hydraulic power is the same 1,469 W.
Two pumps take 2.811 kW, which is 10 percent more than one pump for the same water. ✅
Step 3: The three flows and the crossing
Click to reveal the comparison and the flow where it changes
-
The same steps at 22 and 24 m³/h.
(m³/h) System head (m) One pump: (kW) Two pumps: (kW) 18 30.00 0.898 0.675 2.549 0.859 0.612 2.811 22 33.95 0.973 0.654 3.636 0.918 0.636 3.739 24 36.23 1.013 not possible not possible 0.951 0.645 4.293 One pump takes less power at 18 and at 22 m³/h. ✅
-
One pump cannot reach 24 m³/h. It would need a speed ratio of 1.013, above full speed. At full speed it gives 35.09 m at 24 m³/h, and the system needs 36.23 m. Its limit is the full-speed duty point, 23.34 m³/h. Two pumps deliver 24 m³/h at 95.1 percent of full speed and take 4.293 kW. ✅
-
Where the two inputs are equal. The hydraulic power, the motor and the drive are the same for both arrangements, so the inputs are equal where the pump efficiencies are equal. A root finder gives
Above 23.63 m³/h two pumps would take less power than one. ✅
-
Compare with the limit of one pump. At 23.63 m³/h one pump would need
, which it does not have. The crossing lies just beyond the 23.34 m³/h that one pump can reach. At 23.34 m³/h one pump takes 4.084 kW and two take 4.104 kW. So over the whole range that one pump can serve, one pump takes less power. ✅ -
Check a second way. The efficiency formula is symmetric about 18 m³/h. The two arrangements have equal efficiency when one pump is as far above 18 as each of two pumps is below it. At 23.63 m³/h, one pump has
, which is 5.49 above. Each of two pumps has , which is 5.49 below. Both give . ✅
Verify It in Python
The script solves the duty points of one and two pumps on the three system curves, the pair of unequal pumps, and the speed-control comparison of Application 2. It finds the flow of equal power with a root finder and saves one plot.
"""Two booster pumps in parallel and in series, and when to start the second."""import numpy as npfrom scipy.optimize import brentqimport matplotlib.pyplot as plt
RHO, G = 998.0, 9.81ETA_MOTOR, ETA_DRIVE = 0.88, 0.97
def pump(q, r=1.0): # one booster at speed ratio r return 42.0 * r**2 - 0.012 * q**2
def eta(q_full): # efficiency at the full-speed flow return 0.68 - 0.0012 * (q_full - 18.0) ** 2
def system(q): # the site's distribution system return 22.0 + 0.0247 * q**2
def p_in(q, head, eta_pump, drive=1.0): """Electrical input in kW for flow q (m3/h) at the given head.""" return RHO * G * (q / 3600.0) * head / 1000.0 / eta_pump / (ETA_MOTOR * drive)
def duty(n_parallel, sys_curve, n_series=1): """Duty point of identical pumps at full speed on a system curve.""" return brentq(lambda q: n_series * pump(q / n_parallel) - sys_curve(q), 0.1, 80.0)
# ---------- Application 1: full speed, no drive ----------print("Application 1: parallel pumps on H = 22 + 0.0247 Q^2, full speed")q1, q2 = duty(1, system), duty(2, system)for n, q in ((1, q1), (2, q2)): each = q / n print(f" {n} pump(s): Q = {q:.2f} m3/h, H = {system(q):.2f} m, each {each:.2f} m3/h, " f"efficiency {eta(each):.4f}, input each {p_in(each, system(q), eta(each)):.3f} kW, " f"total {n * p_in(each, system(q), eta(each)):.3f} kW, " f"{n * p_in(each, system(q), eta(each)) / q:.4f} kWh/m3")print(f" gain in flow from the second pump: {100 * (q2 / q1 - 1):.1f} %")print(f" friction head: {system(q1) - 22:.2f} m with one pump, {system(q2) - 22:.2f} m with two")
def flat(q): return 36.0 + 0.0003 * q**2
f1, f2 = duty(1, flat), duty(2, flat)print(f" flat system 36 + 0.0003 Q^2: one pump {f1:.2f} m3/h at {flat(f1):.2f} m, " f"two pumps {f2:.2f} m3/h at {flat(f2):.2f} m, gain {100 * (f2 / f1 - 1):.1f} %")
# ---------- Series ----------def steep(q): return 30.0 + 0.12 * q**2
s1, s2, sp = duty(1, steep), duty(1, steep, n_series=2), duty(2, steep)print("Series pumps on H = 30 + 0.12 Q^2")print(f" one pump: {s1:.2f} m3/h at {steep(s1):.2f} m, efficiency {eta(s1):.4f}")print(f" two in series: {s2:.2f} m3/h at {steep(s2):.2f} m " f"({steep(s2) / 2:.2f} m each), efficiency {eta(s2):.4f}, " f"input each {p_in(s2, steep(s2) / 2, eta(s2)):.3f} kW")print(f" two in parallel on the same system: {sp:.2f} m3/h at {steep(sp):.2f} m")
# ---------- Unequal pumps in parallel ----------def q_big(h): return np.sqrt(max(42.0 - h, 0.0) / 0.012)
def q_small(h): # small pump: H = 36 - 0.02 Q^2 return np.sqrt(max(36.0 - h, 0.0) / 0.02)
h_u = brentq(lambda h: q_big(h) + q_small(h) - np.sqrt((h - 22.0) / 0.0247), 22.5, 41.9)print("Unequal pumps in parallel on the site's system")print(f" small pump delivers nothing at 36 m or more; there the large pump gives " f"{q_big(36.0):.2f} m3/h")print(f" duty: H = {h_u:.2f} m, large pump {q_big(h_u):.2f}, small pump {q_small(h_u):.2f}, " f"total {q_big(h_u) + q_small(h_u):.2f} m3/h")
# ---------- Application 2: speed control, one pump against two ----------def speed_case(q_total, n): """Speed ratio, pump efficiency and total electrical input for n pumps.""" each, head = q_total / n, system(q_total) r = np.sqrt((head + 0.012 * each**2) / 42.0) e = eta(each / r) return r, each / r, e, n * p_in(each, head, e, ETA_DRIVE)
print("Application 2: speed control on H = 22 + 0.0247 Q^2")for q in (18.0, 22.0, 24.0): print(f" Q = {q:.0f} m3/h, system needs {system(q):.2f} m") for n in (1, 2): r, q_eq, e, p = speed_case(q, n) note = " NOT POSSIBLE, above full speed" if r > 1.0 else "" print(f" {n} pump(s): r = {r:.4f}, Q_eq = {q_eq:.2f} m3/h, " f"efficiency {e:.4f}, input {p:.3f} kW, {p / q:.4f} kWh/m3{note}")q_x = brentq(lambda q: speed_case(q, 1)[3] - speed_case(q, 2)[3], 15.0, 26.0)print(f" equal power at Q = {q_x:.2f} m3/h, where one pump would need " f"r = {speed_case(q_x, 1)[0]:.4f}")print(f" one pump at full speed reaches {q1:.2f} m3/h; there one pump takes " f"{speed_case(q1, 1)[3]:.3f} kW and two take {speed_case(q1, 2)[3]:.3f} kW")r_min = np.sqrt(22.0 / 42.0)print(f" no flow below r = {r_min:.4f}")
# ---------- Plot ----------qq = np.linspace(0.0, 50.0, 300)fig, ax = plt.subplots(1, 2, figsize=(10.5, 4.5))ax[0].plot(qq, pump(qq), label="one pump")ax[0].plot(qq, pump(qq / 2.0), label="two in parallel")ax[0].plot(qq, system(qq), "k", label="site system")ax[0].plot(qq, flat(qq), "k--", label="flat system")ax[0].plot([q1, q2], [system(q1), system(q2)], "o", color="black")ax[0].plot([f1, f2], [flat(f1), flat(f2)], "s", color="black")ax[0].set_ylim(20.0, 45.0)ax[0].set_xlabel("flow (m3/h)")ax[0].set_ylabel("head (m)")ax[0].legend(fontsize=8)qs = np.linspace(15.0, 25.5, 200)one = np.array([speed_case(q, 1)[3] if speed_case(q, 1)[0] <= 1.0 else np.nan for q in qs])two = np.array([speed_case(q, 2)[3] for q in qs])ax[1].plot(qs, one, label="one pump, speed control")ax[1].plot(qs, two, label="two pumps sharing equally")ax[1].axvline(q1, color="gray", ls=":", label="limit of one pump")ax[1].set_xlabel("flow (m3/h)")ax[1].set_ylabel("electrical input (kW)")ax[1].legend(fontsize=8)fig.tight_layout()fig.savefig("parallel_series.png", dpi=120)print("Saved parallel_series.png")Expected output
Application 1: parallel pumps on H = 22 + 0.0247 Q^2, full speed 1 pump(s): Q = 23.34 m3/h, H = 35.46 m, each 23.34 m3/h, efficiency 0.6457, input each 3.962 kW, total 3.962 kW, 0.1697 kWh/m3 2 pump(s): Q = 26.87 m3/h, H = 39.83 m, each 13.44 m3/h, efficiency 0.6550, input each 2.525 kW, total 5.050 kW, 0.1879 kWh/m3 gain in flow from the second pump: 15.1 % friction head: 13.46 m with one pump, 17.83 m with two flat system 36 + 0.0003 Q^2: one pump 22.09 m3/h at 36.15 m, two pumps 42.64 m3/h at 36.55 m, gain 93.1 %Series pumps on H = 30 + 0.12 Q^2 one pump: 9.53 m3/h at 40.91 m, efficiency 0.5940 two in series: 19.36 m3/h at 75.00 m (37.50 m each), efficiency 0.6778, input each 3.311 kW two in parallel on the same system: 9.88 m3/h at 41.71 mUnequal pumps in parallel on the site's system small pump delivers nothing at 36 m or more; there the large pump gives 22.36 m3/h duty: H = 35.96 m, large pump 22.43, small pump 1.35, total 23.78 m3/hApplication 2: speed control on H = 22 + 0.0247 Q^2 Q = 18 m3/h, system needs 30.00 m 1 pump(s): r = 0.8983, Q_eq = 20.04 m3/h, efficiency 0.6750, input 2.549 kW, 0.1416 kWh/m3 2 pump(s): r = 0.8588, Q_eq = 10.48 m3/h, efficiency 0.6121, input 2.811 kW, 0.1562 kWh/m3 Q = 22 m3/h, system needs 33.95 m 1 pump(s): r = 0.9730, Q_eq = 22.61 m3/h, efficiency 0.6545, input 3.636 kW, 0.1653 kWh/m3 2 pump(s): r = 0.9182, Q_eq = 11.98 m3/h, efficiency 0.6365, input 3.739 kW, 0.1700 kWh/m3 Q = 24 m3/h, system needs 36.23 m 1 pump(s): r = 1.0135, Q_eq = 23.68 m3/h, efficiency 0.6413, input 4.320 kW, 0.1800 kWh/m3 NOT POSSIBLE, above full speed 2 pump(s): r = 0.9506, Q_eq = 12.62 m3/h, efficiency 0.6453, input 4.293 kW, 0.1789 kWh/m3 equal power at Q = 23.63 m3/h, where one pump would need r = 1.0058 one pump at full speed reaches 23.34 m3/h; there one pump takes 4.084 kW and two take 4.104 kW no flow below r = 0.7237Saved parallel_series.pngThe row marked NOT POSSIBLE shows what one pump would take at 24 m³/h if it could run above full speed. In the right plot, the line for one pump stops at 23.34 m³/h and lies below the line for two pumps all the way to that limit.
Common Mistakes
- Expecting twice the flow from two pumps in parallel. The gain depends on how steep the system curve is, and it is always less than double.
- Adding heads for pumps in parallel, or adding flows for pumps in series. Parallel adds flows at equal head. Series adds heads at equal flow.
- Sizing the motor and checking the NPSH for the shared flow. One pump running alone carries the largest flow, and that is the case to check.
- Putting a weaker pump in parallel with a stronger one without checking the common head. Above its shut-off head the weaker pump delivers nothing.
- Starting the second pump early “to share the load”. At the same total flow, two pumps far from their best efficiency point can take more power than one pump near it.
Summary
- Identical pumps in parallel work at the same head and share the flow:
. Identical pumps in series carry the same flow and add their heads: . - Two boosters in parallel on the distribution system deliver 26.87 m³/h at 39.83 m, each carrying 13.44 m³/h at 65.5 percent efficiency and taking 2.525 kW.
- That is 15.1 percent more flow than one pump for 27 percent more power, because the extra flow needs 4.37 m more friction head.
- On a flat system the same pair gives 93 percent more flow. On a steep system a parallel pump adds 4 percent, and a series pump doubles the flow.
- A weaker pump in parallel delivers nothing when the common head reaches its shut-off head, here 36 m.
- With speed control on this system, one pump takes less power than two at every flow it can reach. The inputs are equal at 23.63 m³/h, just beyond the 23.34 m³/h limit of one pump, so the second pump is started for capacity.
Exercises
1. One pump has the curve
Answer
One pump:
2. A system has the curve
Answer
The static head, 50 m, is above the shut-off head of 42 m, so one pump delivers nothing. In series:
3. The booster (
Answer
At 34 m: large pump
4. For Application 2, find the speed ratio, the pump efficiency and the total electrical input at 20 m³/h with one pump and with two pumps.
Answer
The system needs
5. The two boosters have no drives. They run at full speed and a valve holds the total flow at 24 m³/h. Find the pump head, the head the valve takes, and the total electrical input (motor 0.88). Compare with the 4.293 kW of two pumps under speed control.
Answer
Each pump carries 12 m³/h at
References
- I. J. Karassik, J. P. Messina, P. Cooper and C. C. Heald, Pump Handbook, 4th edition, McGraw-Hill, 2008.
- J. F. Gülich, Centrifugal Pumps, 3rd edition, Springer, 2014.
- F. M. White, Fluid Mechanics, 8th edition, McGraw-Hill, 2016.
- Y. A. Çengel and J. M. Cimbala, Fluid Mechanics: Fundamentals and Applications, 4th edition, McGraw-Hill, 2018.
One booster pump delivers 23.34 m³/h into a distribution system. Of the 35.5 m of head at that flow, 22 m is static and the rest is friction. A second, identical pump is started in parallel with the first. How much more water does the station deliver?
The black curve is one booster pump, H = 42 − 0.012 Q². The coloured curve is the combined curve of the pumps that run. In parallel the flows add at equal head, so the curve is stretched to the right. In series the heads add at equal flow, so it is stretched upward. The dashed curve is the system, 22 + k Q², with the static part fixed at the lesson's 22 m. The slider changes only the friction coefficient k, from a nearly flat system on the left to a steep one on the right. The gold dot is the duty point of the station. The red dot shows what each pump does on its own curve. The open circle is one pump alone on the same system. The pumps run at full speed with no drive, and the motor efficiency is 0.88. The maker's sheet for this pump ends at 28 m³/h, so no efficiency is shown for a pump beyond that flow.
Check yourself
Three questions. Each wrong choice is a mistake people really make, so read the note after you answer.
1. Two boosters run in parallel on the distribution system and deliver 26.87 m³/h at 39.83 m. What does each pump do?
2. Two boosters run in parallel and the discharge valve of the station is closed for a moment. Each pump alone has a shut-off head of 42 m. What head does a gauge on the common discharge show?
3. On the lesson's system two pumps in parallel give 26.87 m³/h. The owner wants more and proposes a third identical pump in parallel. What does it add?
- One booster, H = 42 − 0.012 Q². Two side by side share one head and one main.
- At one head, add the flows: at 36 m, 22.4 m³/h becomes 44.7 m³/h.
- The shut-off head stays 42 m. Two pumps in parallel give more flow, not more head.
- On the system curve the flow rises only from 23.3 to 26.9 m³/h, 15 %. Each pump gives 13.4.
Discussion
No comments yet. Questions, results from your own build, a better way to explain it: all welcome.