Risk priority number
Each factor is from 1 to 10, so the RPN is from 1 to 1,000. It is used only to put the lines of one table in an order. It is not a probability, a cost or a measure of risk.
A cold store has a maintenance plan of forty tasks, copied from the maker’s manual, and every task is done on time. Then a room probe drifts by two degrees, the display still shows a safe temperature, and a week of stock is lost. The failure was not in the plan, because nobody had asked in what ways this machine can fail and what each way would cost. A failure modes and effects analysis asks exactly that, in order, with the people who know the machine. This lesson shows how to run one, how to score it, and why the usual score must be read with care. #FMEA #FailureModes #RiskRanking
By the end of this lesson, you will be able to:
The cold store has two refrigeration compressors, one on duty and one on standby; in normal weather one can hold the load. Each has its own motor, contactor and control sensors. In this example both serve one refrigerant circuit and reject their heat through one condenser.
The five-year record shows 9 compressor failures, about 1.8 a year. It says how often the machine stopped, not which failures deserve the next hour of the technician’s time. Some cost a contactor and two hours of work. Others empty the room.
The analysis covers one compressor with its motor, contactor, oil system, controls and sensors. The shared condenser and the refrigerant circuit are outside the boundary, but each effect must still be followed across it to the room, because that is where the loss happens.
A failure modes and effects analysis (FMEA) is a table, built by a small team, that answers four questions about one machine:
It works from the bottom up, from single failures of parts to their effect on the site. It is organised judgement, not a calculation: its value is in the list, and the scores only help to sort it.
An FMEA looks at one failure at a time. It handles poorly two things that must fail together, such as a compressor failure while the standby is also unavailable. A fault tree is the tool for combinations.
Most poor FMEA tables are poor because these five words are confused. A car shows them: be at work by 8:00 (function), will not start (functional failure), flat battery (failure mode), lights left on (cause), late, with a taxi fare (effect).
A function is what the users want the machine to do, with a number in it. “To compress refrigerant” is weak. “To keep the cold room below 8 °C in the hottest weather the site meets” is a function, because it can be failed in a measurable way. Secondary functions count too: to contain the refrigerant and the oil, to stop safely when a protection device calls, to use no more energy than it should.
A functional failure is the loss of a function, fully or in part: “delivers no cooling”, “delivers less cooling than the load”, “does not contain the refrigerant”.
A failure mode is the event in the machine that produces the functional failure: “contactor does not close”, “discharge valve plate cracked”. It is written as a part and what happened to it.
A cause is the reason behind the failure mode: “contacts burnt by frequent starts”. One mode can have several causes, and the cause is where prevention starts.
An effect is what happens when the mode occurs, if nothing is done. Write it at three levels: at the part (the compressor does not start), at the system (the standby takes over), and at the site (no loss of temperature, repair needed, no standby until it is done).
One part can have more than one failure mode. A contactor can fail to close, and it can also weld closed so that the compressor cannot be stopped. These are two lines of the table, with different effects.
An FMEA written by one person at a desk holds only what that person knows. The method works because an operator, a technician and an engineer each know different failures.
Three things are scored for each failure mode, each from 1 to 10:
Scales copied from a book rarely fit: one written for a car factory has no line for “stock in the room at risk”. Write your own, in words the team can test a failure against. This lesson uses these:
| Severity: the worst effect that can reasonably be expected | |
|---|---|
| 1 | No effect that anybody would notice |
| 2 to 3 | Lower efficiency, no stop, corrected at the next planned visit |
| 4 | Compressor stops, standby takes over, repair below 20,000 currency units |
| 5 | Compressor stops, standby takes over, repair from 20,000 to 100,000 |
| 6 to 7 | Compressor stops, standby takes over, repair above 100,000 (7 if other parts are damaged) |
| 8 | Cooling lost or room temperature wrong: stock at risk |
| 9 | Possible harm to people or to the environment, with some warning |
| 10 | Possible harm to people or to the environment, with no warning |
| Occurrence: failures a year for one compressor | |
|---|---|
| 1 | below 0.02 (less than once in 50 years) |
| 2 | 0.02 to 0.05 |
| 3 | 0.05 to 0.1 |
| 4 | 0.1 to 0.2 |
| 5 | 0.2 to 0.5 |
| 6 | 0.5 to 1 |
| 7 | 1 to 2 |
| 8 | 2 to 5 |
| 9 | 5 to 12 |
| 10 | above 12 (more than once a month) |
A rate on a boundary takes the higher score.
| Detection: how the developing failure is found with the present checks | |
|---|---|
| 1 | Continuous measurement with an alarm that is tested |
| 2 | A protection device stops the machine in time, or the sign is plain on the weekly walk |
| 3 to 4 | A routine check with a gauge or an instrument, weekly (3) or monthly (4) |
| 5 to 6 | No instrument: only if a person notices by ear or touch, or studies a log that nobody plots (5 if the sign is early, 6 if it is late or weak) |
| 7 to 8 | A check exists but is done once a year (7), or there is no check and it is found by chance (8) |
| 9 | No means of finding it before the failure |
| 10 | Not found even after the failure without taking the machine apart |
The occurrence scale is tied to a rate, so a record can settle an argument about it. Severity and detection are judgements, and two honest teams can differ by a point or two on the same machine.
Risk priority number
Each factor is from 1 to 10, so the RPN is from 1 to 1,000. It is used only to put the lines of one table in an order. It is not a probability, a cost or a measure of risk.
The RPN is popular because it is simple, and useful for a first sorting of a long table. It has four weaknesses:
Equal numbers from very different risks.
The scales are ordinal. A severity of 8 is worse than 4 but not twice as bad: on this scale 4 is a repair below 20,000 currency units and 8 is a room of stock. Multiplying treats ranks as quantities.
Detection counts as much as severity. A good alarm lowers the RPN of a dangerous mode by the same factor as a harmless one. The danger is still there on the day the alarm fails.
The number looks finer than it is. The 1,000 combinations of scores give only 120 different products. Half give 100 or less, and only 6 percent more than 500. A change of one point in one score, well inside the disagreement of a team, can move a line several places.
So a fixed rule such as “act on every RPN above 100” is a poor rule. Some newer guides have left the RPN: the 2019 handbook of the automotive bodies AIAG and VDA replaced it with a table of action priorities in which severity carries the most weight.
A better order asks first what kind of consequence a mode has, and only then how large it is. This follows reliability-centred maintenance, where the consequence decides how much effort a failure deserves.
For the cold store the classes are:
Inside class B and class C, a simple and honest measure is the expected cost a year:
The mean cost of one event is not the severity. Severity is the worst reasonable effect; the mean cost averages what usually happens, including the times a protection device or a person stops the event early. Both rest on assumptions, written beside the numbers.
A failure mode with a possible safety or environmental consequence is flagged in the table and taken out of the cost ranking. A low occurrence or a good detection score does not make it acceptable. It goes to a proper safety assessment by qualified people, under the law and the standards of the country; this course does not teach that assessment. The FMEA team’s duty is to make sure such a mode is seen, written down and passed on.
The result is not the table but the actions from the top of the ranking. An action can reduce the occurrence (remove the cause), reduce the severity (a design change, a spare on the shelf), or improve the detection (a measurement, an inspection). The line is scored again only after the action is done.
Primary function. To keep the cold room below 8 °C, together with the condenser and the evaporator, in the hottest weather the site meets. ✅
Secondary functions. To contain the refrigerant and the oil. To stop when a protection device calls. To control the room temperature from a true reading. ✅
Functional failures. (a) Delivers no cooling. (b) Delivers less cooling than the load. (c) Does not contain the refrigerant or the oil. (d) Controls the room to a wrong temperature. Each failure mode below is listed under the functional failure that it produces. ✅
The eight modes with their usual causes.
| Failure mode | Usual causes |
|---|---|
| Bearing wear | Age, poor lubrication, oil thinned by liquid refrigerant |
| Valve failure (plate cracked or leaking) | Liquid entering the cylinder, fatigue, high discharge temperature |
| Loss of refrigerant charge | Leak at a joint, a valve stem or a seal, a pipe cracked by vibration |
| Motor winding failure | Overheating from frequent starts, loss of a phase, moisture, aged insulation |
| Contactor failure (does not close) | Contacts burnt by many operations, loose terminals, coil failure |
| Blocked condenser | Dust and fibres on the coil, a failed condenser fan |
| Oil loss | Oil leak, oil that does not return from the circuit, oil pump failure |
| Control sensor failure (room probe reads low) | Drift, moisture in the probe, damaged cable, probe moved |
Every line names a part and what happened to it. ✅
Effects, followed from the part to the site.
| Failure mode | Effect at the compressor | Effect at the site |
|---|---|---|
| Bearing wear | Noise, vibration and heat for weeks, then seizure and shaft damage | Standby takes over. Major repair, 150,000 |
| Valve failure | Gas leaks back, capacity falls, discharge runs hot | Longer running, more energy. Repair about 40,000 |
| Loss of refrigerant charge | Suction pressure falls, capacity falls, low pressure trips | Refrigerant is released. The circuit is shared, so the standby cannot help |
| Motor winding failure | Motor trips or burns out. Where the motor sits inside the refrigerant, a burn-out also contaminates the oil | Standby takes over. Rewind or new motor, 150,000 |
| Contactor failure | Compressor does not start | Standby takes over. Part 6,000 and 2 technician hours: 9,000 |
| Blocked condenser | Head pressure and energy use rise, then a high pressure trip | The condenser is shared: on a hot day both compressors trip and cooling is lost |
| Oil loss | Oil pressure falls and the switch stops the compressor. If the switch fails, the bearings seize | Standby takes over. Usually a leak repair and a top-up, about 10,000 |
| Control sensor failure | Compressor is stopped too early | The room is warmer than the display shows. The alarm uses the same probe, so it stays silent |
Three modes reach the room in spite of the standby: loss of charge, blocked condenser and sensor failure. ✅
The first finding, before any score. The standby protects against only five of the eight modes. The other three pass through something both compressors share: the circuit, the condenser or the single probe. ✅
Occurrence from the rates. Each rate is placed on the occurrence scale: 0.10 gives 4, 0.40 gives 5, 0.15 gives 4, 0.05 gives 3, 0.50 gives 6, 0.20 and 0.25 give 5. ✅
A check on the rates. The eight rates add to 1.80 failures a year, the same as the record’s 9 failures in 5 years: the team’s estimates are consistent with it. ✅
Severity and detection from the scales, and the RPN.
| Failure mode | RPN | Reason for | |||
|---|---|---|---|---|---|
| Bearing wear | 7 | 4 | 6 | 168 | By ear on the weekly walk, late |
| Valve failure | 5 | 5 | 6 | 150 | Discharge temperature is logged and not plotted, a weak sign |
| Loss of refrigerant charge | 9 | 4 | 4 | 144 | Monthly sight glass and leak check |
| Motor winding failure | 7 | 3 | 8 | 168 | No insulation test, found by chance |
| Contactor failure | 4 | 4 | 9 | 144 | Contacts are enclosed, and no present check shows their state |
| Blocked condenser | 8 | 6 | 2 | 96 | Plain on the weekly walk and on the gauge |
| Oil loss | 7 | 5 | 2 | 70 | Oil pressure switch stops the machine |
| Control sensor failure | 8 | 5 | 8 | 320 | One probe, nothing to compare it with |
For example, bearing wear:
Why oil loss has severity 7 and a small usual cost. Severity is the worst reasonable effect, which is a seizure. The switch normally prevents it, and that is counted in the detection score of 2. ✅
The order. Control sensor failure 320. Bearing wear 168 and motor winding failure 168. Valve failure 150. Loss of refrigerant charge 144 and contactor failure 144. Blocked condenser 96. Oil loss 70. ✅
What the RPN gets right. The top line is the probe that serves both the control and the alarm. Its failure is frequent enough, it puts the stock at risk, and nothing at present would show it. No task in the maker’s manual covers it. ✅
What looks wrong. The only mode that can release refrigerant is fifth, level with a contactor. The blocked condenser, which can stop both compressors, is seventh. ✅
The test. A team can easily differ by one point on any score. The script moves each of the 24 scores by
The top line is firm. Control sensor failure stays in the top three in 99.6 percent of the trials. ✅
The rest is not. Bearing wear, second now, is in the top three in only 52.1 percent, and its rank goes from first to last. Loss of refrigerant charge, fifth now, reaches the top three in 29.9 percent. Every mode except the first can land almost anywhere. ✅
Conclusion. The RPN separates the one clear leader from the rest. The order of ranks 2 to 6 is the noise of the scoring, not information. ✅
The two products. Loss of refrigerant charge:
What each one means. The contactor mode costs 9,000 for one event and, at 0.15 events a year,
How common the problem is. Of the 1,000 possible combinations of scores, 18 give exactly 144, and their severity runs from 2 to 9. The RPN of 144 says nothing about how bad the effect is. ✅
Classes. Class A: loss of refrigerant charge. Class B (cooling lost or temperature wrong): control sensor failure and blocked condenser. Class C (the standby covers): the other five. ✅
Mean cost of a blocked condenser event. The cleaning is
At 0.50 events a year the expected cost is 26,000 a year. ✅
Mean cost of a sensor failure event.
At 0.25 events a year the expected cost is 29,375 a year. ✅
The ranking.
| Rank | Class | Failure mode | Events a year | Mean cost of one | Cost a year | Rank by RPN |
|---|---|---|---|---|---|---|
| 1 | A | Loss of refrigerant charge | 0.15 | safety assessment | not costed | 5 |
| 2 | B | Control sensor failure | 0.25 | 117,500 | 29,375 | 1 |
| 3 | B | Blocked condenser | 0.50 | 52,000 | 26,000 | 7 |
| 4 | C | Valve failure | 0.40 | 40,000 | 16,000 | 4 |
| 5 | C | Bearing wear | 0.10 | 150,000 | 15,000 | 2 |
| 6 | C | Motor winding failure | 0.05 | 150,000 | 7,500 | 3 |
| 7 | C | Oil loss | 0.20 | 10,000 | 2,000 | 8 |
| 8 | C | Contactor failure | 0.15 | 9,000 | 1,350 | 6 |
The seven costed modes add to 97,225 a year, and the two class B modes are 57 percent of it. ✅
The two modes with RPN 144. They were level. Now the refrigerant mode is first and the contactor mode is last. ✅
The blocked condenser. It moves from seventh to third. The RPN placed it low because it is easy to see, which is true and is why the weekly walk must not be dropped. But it happens every second year, and one time in five it stops both compressors. ✅
Bearing wear and motor winding failure. They move from second and third to fifth and sixth: costly but rare, and the standby covers them. ✅
What stays. The control sensor is at the top of the costed modes in both rankings. A finding that holds under two methods can be trusted more than either alone. ✅
Class A. Loss of refrigerant charge is passed to a safety assessment. The FMEA team records it and does not close it with a score. Refrigerant work is for a qualified refrigeration technician. ✅
Control sensor. Fit a second room probe that is independent of the control probe, with an alarm on the difference between the two. Detection goes from 8 to 2 and the RPN from 320 to 80. If 95 percent of the events are then found in time, the mean cost of one event is
Bearings and motor. A monthly vibration reading takes the detection of bearing wear from 6 to 3 (RPN 168 to 84). A yearly insulation test by a licensed electrician takes the motor winding from 8 to 4 (RPN 168 to 84). ✅
Check of the method. After the actions the highest RPN is the valve failure at 150, with the two modes at 144 next. One is the class A mode, its scores unchanged, and the RPN still cannot tell it from the contactor. The class column can. ✅
The script holds the table of Application 1 as data. It checks the occurrence scores against the rates, ranks by RPN, counts what the arithmetic of the RPN allows, tests the ranking against changes of one point, builds the ranking by consequence class of Application 2, and saves a figure of the two rankings side by side.
"""FMEA of one refrigeration compressor: risk priority numbers and a ranking by consequence."""import itertoolsimport numpy as npimport matplotlib.pyplot as plt
TECH_HOUR = 1500.0 # currency unitsMAJOR_REPAIR = 150000.0 # compressor failure, standby takes overSTOCK_LOSS = 230000.0 # stock and disruption when cooling is lost
# name, severity, occurrence, detection, failures a year, class, mean cost of one event# class A: safety or environment, B: cooling lost (standby does not help),# class C: standby takes over, repair cost onlyMODES = [ ("Bearing wear", 7, 4, 6, 0.10, "C", MAJOR_REPAIR), ("Valve failure", 5, 5, 6, 0.40, "C", 40000.0), ("Loss of refrigerant", 9, 4, 4, 0.15, "A", None), ("Motor winding failure", 7, 3, 8, 0.05, "C", MAJOR_REPAIR), ("Contactor failure", 4, 4, 9, 0.15, "C", 6000.0 + 2 * TECH_HOUR), ("Blocked condenser", 8, 6, 2, 0.50, "B", 0.2 * (STOCK_LOSS + 4 * TECH_HOUR) + 0.8 * (4 * TECH_HOUR)), ("Oil loss", 7, 5, 2, 0.20, "C", 10000.0), ("Control sensor failure", 8, 5, 8, 0.25, "B", 0.5 * STOCK_LOSS + 0.5 * 5000.0),]
def occurrence_score(rate): """The site's occurrence scale: failures a year for one compressor.""" edges = [0.02, 0.05, 0.1, 0.2, 0.5, 1.0, 2.0, 5.0, 12.0] return 1 + int(np.searchsorted(edges, rate, side="right"))
names = [m[0] for m in MODES]S = np.array([m[1] for m in MODES])O = np.array([m[2] for m in MODES])D = np.array([m[3] for m in MODES])rate = np.array([m[4] for m in MODES])cls = [m[5] for m in MODES]cost = [m[6] for m in MODES]rpn = S * O * D
print("Occurrence scores from the stated rates:", [occurrence_score(r) for r in rate], "table:", O.tolist())print(f"Sum of the rates: {rate.sum():.2f} failures a year " f"(the record: 9 failures in 5 years = {9 / 5:.2f})")
print("\nApplication 1: ranking by risk priority number")print(" rank mode S O D RPN")order = np.argsort(-rpn, kind="stable")for k, i in enumerate(order, start=1): print(f" {k:4d} {names[i]:23s} {S[i]:2d} {O[i]:2d} {D[i]:2d} {rpn[i]:4d}")
# what the arithmetic of the RPN allowscombos = list(itertools.product(range(1, 11), repeat=3))products = [a * b * c for a, b, c in combos]sev_144 = [a for a, b, c in combos if a * b * c == 144]print(f"\n 1000 combinations of scores give {len(set(products))} different RPN values")low = sum(1 for p in products if p <= 100)print(f" {100 * low / 1000:.1f} % of the combinations give 100 or less, " f"{100 * sum(1 for p in products if p > 500) / 1000:.1f} % give more than 500")print(f" combinations that give 144: {len(sev_144)}, " f"with severity from {min(sev_144)} to {max(sev_144)}")
# how stable is the order if every score may be one point wrong?rng = np.random.default_rng(5)TRIALS = 10000ranks = np.empty((TRIALS, len(MODES)), dtype=int)for k in range(TRIALS): s = np.clip(S + rng.integers(-1, 2, S.size), 1, 10) o = np.clip(O + rng.integers(-1, 2, O.size), 1, 10) d = np.clip(D + rng.integers(-1, 2, D.size), 1, 10) r = s * o * d ranks[k] = (-r).argsort().argsort() + 1print(" every score moved by -1, 0 or +1 at random, 10000 times:")print(" mode rank now best worst in top three")now = (-rpn).argsort(kind="stable").argsort() + 1for i in order: print(f" {names[i]:23s} {now[i]:6d} {ranks[:, i].min():8d} {ranks[:, i].max():6d} " f"{100 * (ranks[:, i] <= 3).mean():10.1f} %")
print("\nApplication 2: two modes with RPN 144")for i in (names.index("Loss of refrigerant"), names.index("Contactor failure")): print(f" {names[i]:23s} S {S[i]} x O {O[i]} x D {D[i]} = {rpn[i]}, class {cls[i]}")i = names.index("Contactor failure")print(f" contactor: one event costs {cost[i]:.0f}, expected {rate[i] * cost[i]:.0f} a year")
print("\n ranking by consequence class, then by expected cost a year")print(" rank class mode per year cost of one cost a year RPN rank")yearly = np.array([np.nan if c is None else r * c for r, c in zip(rate, cost)])key = sorted(range(len(MODES)), key=lambda j: (cls[j], 0.0 if cost[j] is None else -yearly[j]))for k, j in enumerate(key, start=1): one = "safety review" if cost[j] is None else f"{cost[j]:11.0f}" yr = " not costed" if cost[j] is None else f"{yearly[j]:13.0f}" print(f" {k:4d} {cls[j]} {names[j]:23s} {rate[j]:7.2f} {one:>13s} {yr} {now[j]:7d}")total = np.nansum(yearly)b_share = sum(yearly[j] for j in range(len(MODES)) if cls[j] == "B") / totalprint(f" total of the costed modes: {total:.0f} a year; class B is {100 * b_share:.0f} % of it")
# actions and the scores after themprint("\n after the actions (detection score only)")for name, new_d in (("Control sensor failure", 2), ("Bearing wear", 3), ("Motor winding failure", 4)): j = names.index(name) print(f" {name:23s} D {D[j]} to {new_d}: RPN {rpn[j]} to {S[j] * O[j] * new_d}")j = names.index("Control sensor failure")new_cost = 0.05 * STOCK_LOSS + 0.95 * 5000.0print(f" sensor, with 95 % of events found in time: one event costs {new_cost:.0f}, " f"{rate[j] * new_cost:.0f} a year, a saving of {yearly[j] - rate[j] * new_cost:.0f}")
# ---------- Plot ----------fig, ax = plt.subplots(1, 2, figsize=(11, 4.5))ax[0].barh([names[i] for i in order][::-1], rpn[order][::-1])ax[0].set_xlabel("risk priority number")ax[0].set_title("Ranking by RPN")costed = [j for j in key if cost[j] is not None]ax[1].barh([f"{names[j]} ({cls[j]})" for j in costed][::-1], [yearly[j] for j in costed][::-1])ax[1].set_xlabel("expected cost a year (currency units)")ax[1].set_title("Costed modes by class, then cost")fig.tight_layout()fig.savefig("fmea_compressor.png", dpi=120)print("Saved fmea_compressor.png")Expected output
Occurrence scores from the stated rates: [4, 5, 4, 3, 4, 6, 5, 5] table: [4, 5, 4, 3, 4, 6, 5, 5]Sum of the rates: 1.80 failures a year (the record: 9 failures in 5 years = 1.80)
Application 1: ranking by risk priority number rank mode S O D RPN 1 Control sensor failure 8 5 8 320 2 Bearing wear 7 4 6 168 3 Motor winding failure 7 3 8 168 4 Valve failure 5 5 6 150 5 Loss of refrigerant 9 4 4 144 6 Contactor failure 4 4 9 144 7 Blocked condenser 8 6 2 96 8 Oil loss 7 5 2 70
1000 combinations of scores give 120 different RPN values 49.9 % of the combinations give 100 or less, 6.0 % give more than 500 combinations that give 144: 18, with severity from 2 to 9 every score moved by -1, 0 or +1 at random, 10000 times: mode rank now best worst in top three Control sensor failure 1 1 6 99.6 % Bearing wear 2 1 8 52.1 % Motor winding failure 3 1 8 49.1 % Valve failure 4 1 8 34.6 % Loss of refrigerant 5 1 8 29.9 % Contactor failure 6 1 8 27.7 % Blocked condenser 7 2 8 6.4 % Oil loss 8 2 8 0.4 %
Application 2: two modes with RPN 144 Loss of refrigerant S 9 x O 4 x D 4 = 144, class A Contactor failure S 4 x O 4 x D 9 = 144, class C contactor: one event costs 9000, expected 1350 a year
ranking by consequence class, then by expected cost a year rank class mode per year cost of one cost a year RPN rank 1 A Loss of refrigerant 0.15 safety review not costed 5 2 B Control sensor failure 0.25 117500 29375 1 3 B Blocked condenser 0.50 52000 26000 7 4 C Valve failure 0.40 40000 16000 4 5 C Bearing wear 0.10 150000 15000 2 6 C Motor winding failure 0.05 150000 7500 3 7 C Oil loss 0.20 10000 2000 8 8 C Contactor failure 0.15 9000 1350 6 total of the costed modes: 97225 a year; class B is 57 % of it
after the actions (detection score only) Control sensor failure D 8 to 2: RPN 320 to 80 Bearing wear D 6 to 3: RPN 168 to 84 Motor winding failure D 8 to 4: RPN 168 to 84 sensor, with 95 % of events found in time: one event costs 16250, 4062 a year, a saving of 25312Saved fmea_compressor.png1. Two failure modes of a gearbox have the scores
2. Two identical borehole pumps have had 3 failures of the same mode in 8 years. Find the rate for one pump and its occurrence score on the scale of this lesson.
The exposure is
3. A borehole pump has no standby. Its team gives four modes: impeller wear (
RPN: check valve 180, motor winding 168, impeller wear 150, dry running 112. Expected cost a year: impeller wear
4. A failure mode occurs 0.3 times a year. In 60 percent of the events it is found early and costs 8,000 currency units. In the other 40 percent it costs 95,000. A monitoring measure that costs 5,000 a year would find 90 percent of those late events early. Find the expected cost a year before and after, and the net gain.
Before: one event costs
Two lines of an FMEA table have the same risk priority number, 144. One is a refrigerant leak. The other is a contactor that does not close, which the standby compressor covers. Which line do you treat first?
The compressor table of the lesson. The coloured edge is the consequence class: coral for A (safety or environment, not costed), gold for B (cooling lost), grey for C (the standby covers). A shake moves each of the 24 scores by one point up, down or not at all, as two honest teams might differ, and the rows move to their new places. Costs are in currency units, under the lesson's stated assumptions.
Three questions. Each wrong choice is a mistake people really make, so read the note after you answer.
1. A site rule says: act on every line with an RPN above 100. A pressure relief valve that can stick shut scores S 10, O 2, D 3. A conveyor belt that runs off its track scores S 4, O 6, D 5. What is the right handling?
2. Three identical fans have had 3 failures of the same mode in 5 years. On the occurrence scale of this lesson (failures a year for one machine, 0.1 to 0.2 gives 4, 0.2 to 0.5 gives 5, 0.5 to 1 gives 6, and a rate on a boundary takes the higher score), what is the score?
3. Two modes are both class C: the standby covers them. Mode X happens 0.05 times a year and one event costs 200,000. Mode Y happens 0.8 times a year and one event costs 15,000. Which one earns the next hour of the technician's time?