Decide maintenance from evidence, not habit: which failures to prevent, how often to look, and what each stop costs. Ten lessons on the machines of one cold store.

Found this useful?
The hourly vibration reading of the conveyor bearing as a fault grows. It leaves its normal scatter near 1.8 mm/s, crosses an alarm of 2.55 mm/s set from its own healthy record at 291 hours, 6.3 weeks before the failure, and a fixed alarm of 4.5 mm/s at 765 hours, only 3.4 weeks before, on its way to failure at 9.0 mm/s.

Every year the plant stops for a week, good parts are changed "to be safe", and the breakdowns continue; some come in the first weeks, from parts that were new. A technician writes "OK" beside the conveyor bearing, and nine days later it seizes. The same contactor fails for the third time, and the answer is a warning letter. A request of 30,000 for sensors is refused, and in the same month one stop costs more than twice that.

In this course you follow the compressors, the conveyor, the borehole pump and the generator of one cold store. You read how each part fails, set how often to look from how fast a fault grows, rank what matters, and cost a stop. The last lesson turns one year of records into a short list of the failures that cost the most.

From a record to a decision
  1. 1Know how it failsOnly some failure patterns rise with age: 11 percent in the study most often quoted.
  2. 2Read the livesTwelve bearing lives on one line. A slope of 2.13 means they wear out.
  3. 3Look often enoughA round by ear hears the fault too late. A vibration reading finds it weeks ahead.
  4. 4Rank by costThree failure modes carry 85.9 percent of the year's ranked cost.
You will be able to
  1. Read a failure record as MTBF, availability and a Weibull shape, and say how far each can be trusted
  2. Choose a task for each failure mode, and set how often to look from how fast the fault grows
  3. Cost a stop, rank the failures that cost the most, and check whether the action worked

New to this? New to reliability? Start with lesson 1: what the age of a part says about its next failure.

You need A computer with Python, numpy, scipy and matplotlib. Every failure record is made in the lessons.

The engineering behind it

A record of running hours and failures is the raw material of every maintenance decision. This is how that decision is made from it.

Lessons
Lesson 1 · 25 minFailure PatternsEarly, random and wear-out failures, and what a fixed replacement interval does to each.Hazard rateBathtub curveWear-outAge replacement Lesson 2 · 24 minMTBF, MTTR and AvailabilityThree numbers from a compressor's record, what each hides, and why two compressors are less safe than they look.MTBFMTTRAvailabilityShared causes Lesson 3 · 26 minWeibull Analysis of Life DataPlot twelve bearing lives and fifteen board lives, and learn whether each part wears out or fails early.Weibull plotShape and scaleB10 lifeUnits still running Lesson 4 · 30 minFailure Modes and Effects AnalysisList how a compressor can fail and what follows, then rank the modes without hiding the dangerous ones.FunctionsFailure modesRPNConsequence ranking Lesson 5 · 27 minThe P-F Interval and Inspection FrequencyHow often to look, from how fast a fault grows, and why the alarm level sets the warning of a sensor.P-F intervalInspection intervalChance of detectionAlarm level Lesson 6 · 28 minChoosing a Maintenance StrategyFive answers to a failure mode, the best replacement age, and the test interval of a standby generator.RCM logicAge replacementOn-condition tasksFailure-finding Lesson 7 · 26 minCriticality Ranking and SparesRank the machines by what their failure does, and work out how many spares to hold.Risk matrixExpected lossPoisson sparesService level Lesson 8 · 27 minRoot Cause AnalysisFollow a contactor that fails every fourteen months past the part and the person to the setting nobody recorded.EvidenceFive whysCause treeFault tree Lesson 9 · 27 minThe Cost of DowntimeCost one stop, turn a record into a yearly cost, and build a case an owner can check.Cost of a stopCost of unreliabilityBreak-evenBusiness case Lesson 10 · 31 minA Reliability Programme from RecordsThirty-one records become a ranked list, a one-page plan and the indicators that show it worked.Failure recordsBad actorsRanking by costIndicators
More about this course

Every number has a reason

A part is not changed every year because a year feels safe. Each number comes from the record of the machine or from how fast its faults grow.

  • 37 percentof runs reach the MTBF when failures are random: an MTBF is a rate written the other way up, not a lifeMTBF
  • 2,630 to 8,150 hwhere repeated samples of twelve bearings put the B10 life; a handful of failures can say only so muchWeibull
  • 91.7 percentof conveyor bearing faults that a monthly vibration reading catches with a week to act; a monthly round by ear catches 25 percent, none in timeP-F interval
  • 4,942 hoursthe best replacement age of the conveyor bearing, at 2.63 an hour, against 5.92 for run to failure and 1.69 for an on-condition taskStrategy
  • 25,200 startsa year from a thermostat band of 0.3 K, against a contactor life of 30,000 operations; a band of 1.5 K gives a calculated 5.95 yearsRoot cause

Age matters only where the hazard rises.

Constant rate
Age says nothing
  • A coil with an MTBF of 8,000 hours
  • A yearly change leaves its 1.05 failures a year as they were
  • And uses 54 percent more coils

The test: is there a sign to watch, or is a failure cheap?

Wear-out
Age is useful
  • A belt with a Weibull shape of 3
  • Risk in the next 2,000 hours: 0.8 percent when new, 45.2 at 9,000 hours
  • A change at 6,000 hours removes 70 percent of its failures

The test: does a planned change cost less than the failure?

The tools

Pythonnumpy, scipy and matplotlib. Each lesson works the numbers by hand, then checks them in Python.
One cold storeTwo compressors, a conveyor, a borehole pump and a standby generator.
No downloadsEvery failure record is made inside the lesson, so your numbers match the page.
Honest rangesAn MTBF or a Weibull line from few failures comes with how far it can be trusted.
A one-page planThe failures that cost the most, an action for each, and the indicators that show it worked.
Currency unitsMoney in plain units, so every example works in any country.

Honest limits. Reliability figures describe populations and averages; they do not predict the day a given machine will fail. Safety consequences are passed on, never traded against cost. A trend can be kept beyond the machine, compared with its limit and turned into an alert; a trip that protects the machine or people within seconds stays in the local controller.

Before you start

The full course notes

Most sites replace parts on a calendar because it feels safe, and still suffer breakdowns, because most failures have nothing to do with age. Maintenance decided by habit costs twice: once for the work that was not needed, and again for the failure it did not prevent. This course is about deciding from evidence. #Reliability #Maintenance #Uptime

It follows the equipment of one site through every lesson: compressors, a borehole pump, a generator and a conveyor, with failure records that are generated inside each lesson’s script.

What you need

A computer with Python, and three libraries.

Terminal window
pip install numpy scipy matplotlib

Lessons

Lesson 1: Failure Patterns

Why most failures are not caused by age, and what that does to a maintenance plan.

Open

Lesson 2: MTBF, MTTR and Availability

Three numbers that describe a machine’s record, and what each hides.

Open

Lesson 3: Weibull Analysis of Life Data

Read the pattern of failure from a handful of failure times.

Open

Lesson 4: Failure Modes and Effects Analysis

List how a machine can fail, what each failure does, and which matter.

Open

Lesson 5: The P-F Interval and Inspection Frequency

How often to look, worked out from how fast a fault develops.

Open

Lesson 6: Choosing a Maintenance Strategy

Run to failure, fixed interval, on condition: the right one for each failure mode.

Open

Lesson 7: Criticality Ranking and Spares

Rank machines by what their failure costs, and decide which spares to hold.

Open

Lesson 8: Root Cause Analysis

Go past the broken part to the reason it broke.

Open

Lesson 9: The Cost of Downtime

Put a number on an hour of lost running, and use it to justify maintenance.

Open

Lesson 10: A Reliability Programme from Records

Build the plan for one site from its own failure and running records.

Open

What this course does not cover

Reliability figures describe populations and averages. They do not predict the day a particular machine will fail, and no lesson here claims that they do.



© 2021-2026 SiliconWit®. All rights reserved.